BANTE A131-NH3 laboratory Ion Meter ammonia ion
Equipped with 7-inch TFT display, supports a variety of ion Measuring methods and concentration units. Automatic identification of electrodes, calibrated management, Data storage and other practical functions, a wide range of Measurement range and high-precision
Bante-
LEICI PI-1-01 type iodine ion electrode adapted to pH, Ion Meter BNC (Q18 type)
$ 120.00 -
Bante321-Cd High Precision Portable Cadmium Ion Concentration Meter
$ 671.00 -
BANTE S30-Na Wireless Bluetooth Sodium Ion Meter 0.00001~ 1mol/L
$ 706.00 -
HANNA HI729 Fluoride LR Tintometer
$ 192.00 -
HANNA HI781 Nitrate LR Tintometer
$ 197.00
A131 Precision LABOratory Ion Meter
Precision laboratory Ion Meter, 7-inch TFT display screen, 5 ion measurement methods are optional, the system menu contains 13 optional parameters, the instrument is suitable for measuring the ion concentration of liquid and water hardness value.
Ion mode features:
• Precision laboratory Ion Meter with 7-inch TFT display.
• Optional ion measurement methods, including direct reading method, known addition method, known subtraction method, sample addition method and sample subtraction method.
• Optional concentration units, including ppm, mg/L, mol/L, mmol/L.
• 2 to 5-point key calibration, including 8 optional concentration calibration points.
• Automatic identification of ion-selective electrodes without specifying ion types.
• Electrode management can store the slope of 3 ion electrodes and recall the calibration data of each electrode.
• Calibration report provides calibration standards and electrode slope details.

laboratory Ion Meter
Water hardness mode features:
• 2 to 5 point key calibration from low to high concentration.
• Optional water hardness units, including German degrees, British degrees, French degrees, mmol/L and mg/L.
General features:
• Calibration due reminder to remind users to calibrate the meter regularly.
• Automatic end point locking, retaining stable measurement values for easy viewing and recording.
• Interval reading mode, regularly send measured values to PC or printer.
• Password protection to prevent unauthorized calibration and settings.
• Expanded memory can store up to 1000 sets of data.
• USB communication interface is easy to connect external devices.
• One key reset (Reset) automatically restores the instrument to the factory default settings.
Series
| model | parameter | describe |
| A131-NH4 | Ammonium | Measuring range: 5×10-6 ~1M, Accuracy: ±0.5% FS |
| A131-Br | bromine | Measuring range: 5×10-6 ~1M, Accuracy: ±0.5% FS |
| A131-Ca | calcium | Measuring range: 5×10-7 ~1M, Accuracy: ±1% FS |
| A131-CL | chlorine | Measuring range: 5×10-6 ~1M, Accuracy: ±0.5% FS |
| A131-Cn | Cyanide | Measuring range: 5×10-6 ~0.01M, Accuracy: ±1% FS |
| A131-F | fluorine | Measuring range: 1×10-6 M~saturation, accuracy: ±0.5% FS |
| A131-NO3 | Nitrate | Measuring range: 7×10-6 ~1M, Accuracy: ±0.5% FS |
| A131-Ag | silver | Measuring range: 1×10-7 ~1M, Accuracy: ±1% FS |
| A131-Na | sodium | Measuring range: 1×10-5 ~1M, Accuracy: ±0.5% FS |
| A131-Cd | cadmium | Measuring range: 1×10-6 ~0.1M, Accuracy: ±1% FS |
| A131-Cu | copper | Measuring range: 1×10-8 ~0.1M, Accuracy: ±1% FS |
| A131-I | iodine | Measuring range: 5×10-8 ~1M, Accuracy: ±1% FS |
| A131-Pb | lead | Measuring range: 1×10-8 ~0.1M, Accuracy: ±1% FS |
| A131-K | Potassium | Measuring range: 1×10-6 ~1M, Accuracy: ±1% FS |
| A131-S | sulfur | Measuring range: 1×10-7 ~1M, Accuracy: ±1% FS |
| A131-NH3 | ammonia | Measuring range: 1×10-6 ~1M, Accuracy: ±1% FS |
| A131-WH | water hardness | Measuring range: 0.05~200mmol/L, accuracy: ±1% FS |
Bante A131-NH3 Laboratory Ion MeterSpecifications
| LIST | VALUE |
|---|---|
| Ion Measurement Range | 1×10-6~1M |
| Ion measurement Accuracy | ±1% F.S |
| Display resolution | 0.001, 0.01, 0.1, 1 |
| Ion calibrated point | 2 to 5 point |
| Ion measurement mode | Direct reading method, known addition method, known reduction method, sample addition method, sample reduction method |
| mV range | -2000~2000mV |
| mV measurement Accuracy | ±0.2mV |
| mV Display resolution | 0.1mV |
| mV calibrated point | 1 point (only for R.mV mode) |
| mV measurement mode | Relative or absolute mV |
| Temperature Measurement Range | 0~105℃, 32~221℉ |
| Temperature measurement Accuracy | ±0.5℃ |
| Display resolution | 0.1℃ |
| Temperature calibrating point | 1 point |
| Temperature unit | ℃/℉ |
| Temperature compensation range | 0~100℃, 32~212℉ |
| Temperature compensation method | Manual/Automatic |
| data lock | Manual or automatic end point locking |
| Data stability condition | Standard or high-precision |
| Calibrated reminder | 1 to 31 days or closed |
| Interval reading | 10, 30, 60 seconds, 10, 30 minutes or off |
| One-click reset function | contain |
| data storage | 1000 sets |
| Interface | USB |
| Connector | BNC |
| Display | 7-Inch TFT LCD |
| Power supply type | DC12V power adapter |
| Dimensions | 240*200*80*mm |
| Instrument Weight | 1.7kg |
| Optional | Ionic standard solution, ionic strength regulator, TP-10K temperature probe |
| Packaging Dimensions | 300*240*170mm |
| Encasement Weight | 2kg |
Bante A131-NH3 Laboratory Ion Meter Packing list
Host X1, NH3-US Ammonia Gas sensing electrode (made in the United States) X1, TP-10K temperature probe X1, DC12V power adapter X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


A131-NH3






