Bante950-UK Laboratory conductivity /TDS/salinity/resistivity meter
BANTE Bante950-UK laboratory conductivity /TDS/salinity/resistivity meter high-precision laboratory Conductivity Meter, 5-point button calibrate, automatic information prompt, built-in system menu can customize 11 functional parameters, the meter is suitable for measurement of liquid conductivity, total dissolved solids (TDS), salinity and resistivity value, Measurement accuracy: 0.5% F.S.
Bante-
BANTE A150-DL Laboratory conductivity /TDS/salinity/resistivity meter
$ 652.00 -
FANGZHOU FZ-704W Conductivity Detector electrode (platinum black) 200µs/cm-200mS/cm
$ 133.00 -
Kodida CT-3031 conductivity meter 0~19.99 mS/cm
$ 114.00 -
Bante520-S portable conductivity meter for routine applications
$ 256.00 -
LEICI DJS-0.01C Type Titanium Alloy Conductivity Detector electrode Three-core aviation plug
$ 203.00
Bante950 Precision Conductivity/TDS/Salinity/Resistivity Meter
High-precision laboratory conductivity meter, 5-point key calibration, automatic information prompt, built-in system menu can customize 11 functional parameters, the instrument is suitable for measuring liquid conductivity, total dissolved solids (TDS), salinity and resistivity value, measurement accuracy: 0.5% FS.
Features
• High-precision laboratory conductivity meter, equipped with a large backlit LCD display.
• 1 to 5 point key calibration, automatic identification of conductivity calibration solution.
• Selectable cell constant (K=0.1/1/10), TDS factor, normalized temperature (20 or 25°C), linear and pure water temperature compensation, seawater practical salinity measurement modes.

Conductivity TDS salinity meter
• Automatic temperature compensation to ensure accurate measurement over the full range.
• Automatic end point locking, retaining stable measurement values for viewing or recording.
• Automatic electrode diagnosis, you can check the electrode slope value (K).
• The system menu can customize 11 functional parameters such as the number of calibration points, stability standard, data lock mode, and automatic shutdown.
• One key reset (Reset) automatically restores the instrument to the factory default settings.
• Expanded memory can store up to 500 sets of measurement data.
• The built-in clock automatically marks the time and date of stored data to comply with GLP regulations.
• USB communication interface to send stored data to PC.

Conductivity TDS salinity meter
Applications:
• Water and Wastewater Treatment
• Research and Education
• Environmental monitoring and farming
• printing and chemical industry
• Fish farming and hydroponics
• Beverage industry and other industrial applications
Bante Bante950-UK Laboratory conductivity /TDS/salinity/resistivity meterSpecifications
| LIST | VALUE |
|---|---|
| Measuring range | 0.01~20mS/cm |
| resolution | 0.001, 0.01, 0.1, 1 |
| Temperature compensation range | 0~100℃ |
| Power | DC5V power adapter |
| Dimensions | 210*188*60mm |
| Weight | 1.5kg |
| Conductivity Detector measurement Accuracy | ±0.5% F.S |
| Conductivity Detector calibrated point | 1 to 5 point |
| Calibrating fluid | 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm |
| Temperature compensation method | Manual/Automatic |
| temperature compensation coefficient | 0.0~10.0%/℃ |
| Temperature compensation mode | Linear or pure water |
| Conductivity Detector cell constant | K = 0.1, 1, 10, custom |
| Standardized temperature | 20 ℃, 25 ℃, optional |
| TDS range | 0~10ppt (Max. 20ppt) |
| TDS measurement Accuracy | ±1% F.S. |
| TDS conversion factor | 0.1~ 1.0 (default 0.5) |
| Salinity range | 0~10ppt |
| Salinity measurement Accuracy | ±1% F.S |
| Salinity measurement mode | Practical salinity (psu) or seawater salinity (ppt) |
| Resistivity Measurement range | 0 ~ 10MZ |
| Resistivity measurement Accuracy | ±1% F.S |
| Resistivity display resolution | 0.01, 0.1, 1 |
| Temperature Measurement range | 0~105℃ |
| Temperature measurement Accuracy | ±0.5℃ |
| Temperature display resolution | 0.1℃ |
| Temperature calibrating point | 1 point |
| Temperature unit | ℃/℉ |
| data lock | Manual or automatic end point locking |
| Data stability condition | Fast or high precision |
| Calibrated reminder | 1 to 31 days or closed |
| shutdown mode | Manual/Automatic |
| One-click reset function | contain |
| data storage | 500 groups |
| Data Interface | USB |
| Connector | 6-Pin MINI Connector |
| Display | Customized LCD (130 × 110mm) |
| Optional accessories | TP-10K temperature probe, Conductivity Detector standard liquid, K10 platinum Conductivity Detector electrode (made in UK) |
| Packaging Dimensions | 300*240*170mm |
| Encasement Weight | 1.7kg |
| Temperature compensation method | Manual/Automatic |
Bante Bante950-UK Laboratory conductivity /TDS/salinity/resistivity meter Packing list
Host X1, K10 Platinum Conductivity detector electrode (made in UK) X1, TP-10K temperature probe X1, DC5V power adapter X1, Conductivity detector standard solution (84 µS/cm, 1413 µS/cm, 12.88mS/cm) X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJG 2059-2014
- ActiveJJF 2105-2024
- ActiveJB/T 9366-2017
- ActiveSL 78-1994
- ActiveGB/T 12582-1990
- ActiveGB/T 13580.3-1992
- ActiveGB/T 6539-1997
- ActiveGB/T 18932.15-2003
- ActiveGB/T 11007-2008
- ActiveGB/T 23977-2009
- ActiveGB/T 41079.2-2022
- ActiveGB/T 6908-2018
- ActiveGB/T 7977-2007
- ActiveGB/T 32697-2016
- ActiveGB/T 33328-2016
- ActiveISO 21318-2007
- ActiveGB/T 27503-2011
- ActiveGB/T 27502-2011
- ActiveJB/T 9366-1999
- ActiveJB/T 6855-1993