BANTE A150-S Laboratory conductivity /TDS/salinity/resistivity meter
Simultaneously detect conductivity, TDS, salinity, resistivity value, Conductivity Detector ash, Measurement range 0.01~ 20mS/cm, automatic temperature compensation, with calibrated reminder and password protection function.
Bante-
LEICI DDSJ-307F Conductivity Meter conductivity Electrical resistivity TDS salinity, temperature 1.0 class
$ 539.00 -
Bante DDS-12D Economical Chinese Screen Laboratory Conductivity Meter Platinum Conductivity Detector Temperature electrode
$ 214.00 -
LEICI DJS-0.1VTG Conductivity Detector electrode 0.05~ 200μS/cm
$ 189.00 -
BANTE IE-50LT Industrial Conductivity Detector electrode measurement Low Conductivity Detector liquid conductivity value
$ 302.00 -
LEICI DDB-303A high-precision Conductivity Meter conductivity /TDS/temperature 1.0 class
$ 316.00
A150 LABOratory Conductivity/TDS/Salinity/Resistivity/Conductivity Ash Meter
Professional laboratory conductivity meter, including 5 measurement functions, 1000 sets of data storage, the meter is suitable for measuring liquid conductivity, total dissolved solids (TDS), salinity, resistivity and conductivity ash value, measurement accuracy: 0.5 %FS.
Features
• Professional laboratory conductivity meter with 7-inch TFT display.
• 1 to 5 point key calibration, automatic identification of conductivity standard solution.
• Selectable cell constants to match connected conductivity electrodes and recall calibration data for each sensor.
• Optional linear temperature compensation coefficient, pure water compensation coefficient, normalized temperature and TDS conversion factor.

LABOratory Conductivity Meter
• Automatic temperature compensation to ensure accurate measurement over the full range.
• Alarm limit, automatically warns if the measured value exceeds the set range.
• Calibration due reminder to remind users to calibrate the meter regularly.
• Automatic end point locking, retaining stable measurement values for easy viewing and recording.
• Interval reading mode, regularly send measured values to PC or printer.
• Password protection to prevent unauthorized calibration and settings.
• Expanded memory can store up to 1000 sets of data.
• USB communication interface is easy to connect external devices.
• One key reset (Reset) automatically restores the instrument to the factory default settings.
Bante A150-S Laboratory conductivity /TDS/salinity/resistivity meterSpecifications
| LIST | VALUE |
|---|---|
| Measuring range | 0.01~20mS/cm |
| resolution | 0.001, 0.01, 0.1, 1 |
| Conductivity Detector measurement Accuracy | ±0.5% F.S |
| Conductivity Detector calibrated point | 1 to 3 point |
| Calibrating fluid | 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm |
| TDS range | 0~10ppt (Max. 20ppt) |
| TDS measurement Accuracy | ±1% F.S. |
| TDS conversion factor | 0.01~ 1.00 (default 0.5) |
| Salinity range | 0~10ppt |
| Salinity range | ±1% F.S |
| Salinity measurement mode | Practical salinity (psu), seawater salinity (ppt),% salinity |
| Resistivity Measurement range | 0 ~ 10MZ |
| Resistivity measurement Accuracy | ±1% F.S |
| Resistivity display resolution | 0.01, 0.1, 1 |
| Conductivity Detector ash Measurement range | 0.00~100% |
| Conductivity Detector ash measurement Accuracy | ±1% F.S |
| Conductivity Detector ash measurement mode | Refined or jagged sugar |
| Temperature Measurement range | 0~105℃ |
| Temperature measurement Accuracy | ±0.5℃ |
| Temperature display resolution | 0.1℃ |
| Temperature calibrating point | 1 point |
| Temperature unit | ℃/℉ |
| Temperature compensation range | 0~100℃ |
| Temperature compensation mode | Linear, nonlinear or pure water compensation |
| Standardized temperature | 20 ℃, 25 ℃, optional |
| Conductivity Detector cell constant | Two-ring electrode (K = 0.1, 1, 10) or four-ring electrode |
| Data stability condition | Standard or high precision |
| Interval reading | 10, 30, 60 seconds, 10, 30 minutes or off |
| Calibrated reminder | 1 to 31 days or closed |
| data storage | 1000 groups |
| Data Interface | USB |
| Connector | 6-Pin MINI Connector |
| Display | 7-Inch TFT LCD |
| Power | DC12V power adapter |
| Dimensions | 240*200*80mm |
| Weight | 1.7kg |
| Optional accessories | TP-10K temperature probe, CON-0.1 type Conductivity Detector electrode, CON-1 type Conductivity Detector electrode, CON-10 type Conductivity Detector electrode, Conductivity Detector standard solution |
| Packaging Dimensions | 300*240*170mm |
| Encasement Weight | 2kg |
| Temperature compensation method | Manual/Automatic |
Bante A150-S Laboratory conductivity /TDS/salinity/resistivity meter Packing list
Host X1, Conductivity detector standard solution (84 µS/cm, 1413 µS/cm, 12.88mS/cm) X1, Con-1 type Conductivity detector electrode X1, TP-10K temperature probe X1, DC12V power adapter X1, Conductivity detector standard solution (84 µS/cm, 1413 µS/cm, 12.88mS/cm) X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJG 2059-2014
- ActiveJJF 2105-2024
- ActiveJB/T 9366-2017
- ActiveSL 78-1994
- ActiveGB/T 12582-1990
- ActiveGB/T 13580.3-1992
- ActiveGB/T 6539-1997
- ActiveGB/T 18932.15-2003
- ActiveGB/T 11007-2008
- ActiveGB/T 23977-2009
- ActiveGB/T 41079.2-2022
- ActiveGB/T 6908-2018
- ActiveGB/T 7977-2007
- ActiveGB/T 32697-2016
- ActiveGB/T 33328-2016
- ActiveISO 21318-2007
- ActiveGB/T 27503-2011
- ActiveGB/T 27502-2011
- ActiveJB/T 9366-1999
- ActiveJB/T 6855-1993


A150-S
A150-UK
A150-DH
A150-DL