BANTE A151-DH Laboratory conductivity /TDS/salinity/resistivity meter
A151 laboratory conductivity /TDS/salinity/resistivity meter, professional precision Conductivity Meter, including 4 measurement functions, 7-inch TFT display, the meter is suitable for the measurement of liquid conductivity, total dissolved solids (TDS), salinity and resistivity values, Measurement accuracy: 0.5% F.S.
Bante-
BANTE IE-50HT Industrial Conductivity Detector electrode for measurement of high Conductivity Detector liquid conductivity value
$ 134.00 -
DDKSIC CON201T Conductivity Detector electrode for laboratory and outdoor measurement of conventional water samples
$ 109.00 -
DDKSIC EC10 Portable Conductivity Meter (color screen) conductivity/resistivity/TDS/salinity/℃
$ 489.00 -
Bante530-DL portable conductivity meter for measurement of pure water
$ 419.00 -
HANNA HI98303 Low range conductivity EC Tester
$ 186.00
A151 LABOratory Conductivity/TDS/Salinity/Resistivity Meter
Professional precision conductivity meter, including 4 measurement functions, 7-inch TFT display, the meter is suitable for measuring liquid conductivity, total dissolved solids (TDS), salinity and resistivity values, measurement accuracy: 0.5% FS.
Features
• Professional precision conductivity meter with 7-inch TFT display.
• 1 to 5 point key calibration, automatic identification of conductivity standard solution.
• Selectable cell constants to match connected conductivity electrodes and recall calibration data for each sensor.
• Optional linear temperature compensation coefficient, pure water compensation coefficient, normalized temperature and TDS conversion factor.

Precision Conductivity Meter
• Automatic temperature compensation to ensure accurate measurement over the full range.
• Alarm limit, automatically warns if the measured value exceeds the set range.
• Calibration due reminder to remind users to calibrate the meter regularly.
• Automatic end point locking, retaining stable measurement values for easy viewing and recording.
• Interval reading mode, regularly send measured values to PC or printer.
• Password protection to prevent unauthorized calibration and settings.
• Expanded memory can store up to 1000 sets of data.
• USB communication interface is easy to connect external devices.
• One key reset (Reset) automatically restores the instrument to factory default settings
Bante A151-DH Laboratory conductivity /TDS/salinity/resistivity meterSpecifications
| LIST | VALUE |
|---|---|
| Measurement range | 0.01~200mS/cm |
| Resolution | 0.001, 0.01, 0.1, 1 |
| EC measurement Accuracy | ±0.5% F.S |
| Conductivity calibrated point | 1 to 3 point |
| Calibrating fluid | 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm |
| TDS range | 0~100ppt (Max. 200ppt) |
| TDS measurement Accuracy | ±1% F.S. |
| TDS conversion factor | 0.01~ 1.00 (default 0.5) |
| Salinity range | 0~80ppt |
| Salinity measurement Accuracy | ±1% F.S |
| Salinity measurement mode | Utility salinity (psu), seawater salinity (ppt),% salinity |
| Electrical resistivity Measurement Range | 0~10MΩ |
| Electrical resistivity measurement Accuracy | ±1% F.S |
| Electrical resistivity Display resolution | 0.01, 0.1, 1 |
| Temperature Measurement Range | 0~105℃ |
| Temperature measurement Accuracy | ±0.5℃ |
| Display resolution | 0.1℃ |
| Temperature calibrating point | 1 point |
| Temperature unit | ℃/℉ |
| Temperature compensation range | 0~100℃ |
| Temperature compensation mode | Linear, nonlinear or pure water compensation |
| Standardized temperature | 20 ℃, 25 ℃, optional |
| Conductivity Detector pool constant | Two-ring electrode (K = 0.1, 1, 10) or four-ring electrode |
| Data stability condition | Standard or high-precision |
| Interval reading | 10, 30, 60 seconds, 10, 30 minutes or off |
| Calibrated reminder | 1 to 31 days or closed |
| Data storage | 1000 sets |
| Interface | USB |
| Connector | 6-Pin MINI Connector |
| Display | 7-Inch TFT LCD |
| Power | DC12V power adapter |
| Dimensions | 240*200*80mm |
| Weight | 1.7kg |
| Optional | TP-10K temperature probe, Conductivity Detector standard solution, CON-0.1 type Conductivity Detector electrode, CON-1 type Conductivity Detector electrode, CON-10 type Conductivity Detector electrode |
| Packaging Dimensions | 300*240*170mm |
| Encasement Weight | 2kg |
| Temperature compensation method | Manual/Automatic |
Bante A151-DH Laboratory conductivity /TDS/salinity/resistivity meter Packing list
Host X1, Conductivity detector standard solution (84 µS/cm, 1413 µS/cm, 12.88mS/cm) X1, CON-1 Conductivity detector electrode X1, CON-10 Conductivity detector electrode X1, TP-10K temperature probe X1, DC12V power adapter X1, Conductivity detector standard solution (84 µS/cm, 1413 µS/cm, 12.88mS/cm) X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJG 2059-2014
- ActiveJJF 2105-2024
- ActiveJB/T 9366-2017
- ActiveSL 78-1994
- ActiveGB/T 12582-1990
- ActiveGB/T 13580.3-1992
- ActiveGB/T 6539-1997
- ActiveGB/T 18932.15-2003
- ActiveGB/T 11007-2008
- ActiveGB/T 23977-2009
- ActiveGB/T 41079.2-2022
- ActiveGB/T 6908-2018
- ActiveGB/T 7977-2007
- ActiveGB/T 32697-2016
- ActiveGB/T 33328-2016
- ActiveISO 21318-2007
- ActiveGB/T 27503-2011
- ActiveGB/T 27502-2011
- ActiveJB/T 9366-1999
- ActiveJB/T 6855-1993


A151-DH
A151-S
A151-DL