      Home> Conductivity Meter> Bante> Bante A151-UK Laboratory conductivity /TDS/salinity/resistivity Meter

      BANTE A151-UK Laboratory conductivity /TDS/salinity/resistivity meter

      A151 laboratory conductivity /TDS/salinity/resistivity meter, professional precision Conductivity Meter, including 4 measurement functions, 7-inch TFT display, the meter is suitable for the measurement of liquid conductivity, total dissolved solids (TDS), salinity and resistivity values, Measurement accuracy: 0.5% F.S.

      Brand
      SKU: NB014817
      China Bante
      VS
      Genuinegoods
      • Bante A151-UK Laboratory conductivity /TDS/salinity/resistivity MeterOverview

      • Specifications
      • Comments
      • FAQs
      A151-UK
      Laboratory conductivity /TDS/salinity/resistivity Meter

      A151 LABOratory Conductivity/TDS/Salinity/Resistivity Meter

      Professional precision conductivity meter, including 4 measurement functions, 7-inch TFT display, the meter is suitable for measuring liquid conductivity, total dissolved solids (TDS), salinity and resistivity values, measurement accuracy: 0.5% FS.

      Features

      • Professional precision conductivity meter with 7-inch TFT display.

      • 1 to 5 point key calibration, automatic identification of conductivity standard solution.

      • Selectable cell constants to match connected conductivity electrodes and recall calibration data for each sensor.

      • Optional linear temperature compensation coefficient, pure water compensation coefficient, normalized temperature and TDS conversion factor.

      Precision Conductivity Meter

      Precision Conductivity Meter


      • Automatic temperature compensation to ensure accurate measurement over the full range.

      • Alarm limit, automatically warns if the measured value exceeds the set range.

      • Calibration due reminder to remind users to calibrate the meter regularly.

      • Automatic end point locking, retaining stable measurement values for easy viewing and recording.

      • Interval reading mode, regularly send measured values to PC or printer.

      • Password protection to prevent unauthorized calibration and settings.

      • Expanded memory can store up to 1000 sets of data.

      • USB communication interface is easy to connect external devices.

      • One key reset (Reset) automatically restores the instrument to factory default settings


      VS

      Bante A151-UK Laboratory conductivity /TDS/salinity/resistivity MeterSpecifications

      LIST VALUE
      Measuring range 0.01~20mS/cm
      resolution 0.001, 0.01, 0.1, 1
      Conductivity Detector measurement Accuracy ±0.5% F.S
      Conductivity Detector calibrated point 1 to 3 point
      Calibrating fluid 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm
      TDS range 0~10ppt (Max. 20ppt)
      TDS measurement Accuracy ±1% F.S.
      TDS conversion factor 0.01~ 1.00 (default 0.5)
      Salinity range 0~10ppt
      Salinity measurement Accuracy ±1% F.S
      Salinity measurement mode Practical salinity (psu), seawater salinity (ppt),% salinity
      Resistivity Measurement range 0 ~ 10MZ
      Resistivity measurement Accuracy ±1% F.S
      Resistivity display resolution 0.01, 0.1, 1
      Temperature Measurement range 0~105℃
      Temperature measurement Accuracy ±0.5℃
      Temperature display resolution 0.1℃
      Temperature calibrating point 1 point
      Temperature unit ℃/℉
      Temperature compensation range 0~100℃
      Temperature compensation mode Linear, nonlinear or pure water compensation
      Standardized temperature 20 ℃, 25 ℃, optional
      Conductivity Detector cell constant Two-ring electrode (K = 0.1, 1, 10) or four-ring electrode
      Data stability condition Standard or high precision
      Interval reading 10, 30, 60 seconds, 10, 30 minutes or off
      Calibrated reminder 1 to 31 days or closed
      data storage 1000 groups
      Data Interface USB
      Connector 6-Pin MINI Connector
      Display 7-Inch TFT LCD
      Power DC12V power adapter
      Dimensions 240*200*80mm
      Weight 1.7kg
      Optional accessories TP-10K Temperature Probe, Conductivity Detector
      Packaging Dimensions 300*240*170mm
      Encasement Weight 2kg
      Temperature compensation method Manual/Automatic

      Bante A151-UK Laboratory conductivity /TDS/salinity/resistivity Meter Packing list

      Host X1, Conductivity detector standard solution (84 µS/cm, 1413 µS/cm, 12.88mS/cm) X1, K10 platinum Conductivity detector electrode (made in UK) X1, TP-10K temperature probe X1, DC12V power adapter X1, Conductivity detector standard solution (84 µS/cm, 1413 µS/cm, 12.88mS/cm) X1, manual X1, certificate X1, warranty card X1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Do you have the resistivity meters required by the ASTMD 4399-90 standard?
      [A]
      This A151-UK resistivity meter will do.
      Bante
      BANTE A151-UK Laboratory conductivity /TDS/salinity/resistivity meter
      Service
      Focus on online sales of Lab Testing Instruments