Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> STIP-scan> Bante> Bante Bante980 Laboratory Dissolved Oxygen Meter
      Bante Bante980 Laboratory Dissolved Oxygen Meter

      Bante980 laboratory Dissolved Oxygen Meter

      Standard laboratory Dissolved Oxygen Meter, 1 or 2 point calibrated, 10 function parameters can be customized in the setting menu, the meter is suitable for daily laboratory applications, Measurement accuracy: 0.2mg/L.

      Brand
      SKU: NB014819
      China Bante
      Stock
      Loading…
      Price
      $ 464.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • Bante Bante980 Laboratory Dissolved Oxygen MeterOverview

        • Specifications
        • Comments
        • FAQs
        Bante980
        Laboratory Dissolved Oxygen Meter
        • Bante980 laboratory Dissolved Oxygen Meter
        Standard laboratory Dissolved Oxygen Meter, 1 or 2 point calibrated, 10 function parameters can be customized in the setting menu, the meter is suitable for daily laboratory applications, Measurement accuracy: 0.2mg/L.

        Bante980 LABOratory Dissolved Oxygen Meter

        Standard laboratory Dissolved Oxygen Meter, 1 or 2-point key calibration, 10 functional parameters are optional, the instrument is equipped with a large-screen LCD display, real-time display of help information, measurement accuracy: 0.2mg/L.

        Features

        • Standard laboratory Dissolved Oxygen Meter with large backlit LCD display.

        • 1 or 2 point pushbutton calibration using air saturated water or zero oxygen liquid.

        • Manual salinity and atmospheric pressure compensation to improve the measurement accuracy of the instrument.

        • Automatic temperature compensation to eliminate measurement deviations at different temperatures.

        • Automatic end point locking, retaining stable measurement values for viewing or recording.

        • Manual temperature calibration to improve the temperature measurement accuracy of the instrument.

        • Optional temperature unit and dissolved oxygen concentration unit (mg/L or ppm) to adapt to the usage habits of different countries.

        • The system menu can customize 9 functional parameters such as the number of calibration points, stability standard, display resolution, data lock mode, and automatic shutdown mode.

        • One key reset (Reset) automatically restores the instrument to the factory default settings.

        • Expanded memory can store up to 500 sets of measurement data.

        • The built-in clock automatically marks the time and date of stored data to comply with GLP regulations.

        • USB communication interface to send stored data to PC.

        LABOratory Dissolved Oxygen Meter

        LABOratory Dissolved Oxygen Meter

        Applications:

        • Research and Education

        • Environmental monitoring and ecological research

        • Water and Wastewater Treatment

        • Other industrial applications

        VS

        Bante Bante980 Laboratory Dissolved Oxygen MeterSpecifications

        LIST VALUE
        DO range 0.00~20.00mg/L
        DO measurement Accuracy ±0.2mg/L
        DO resolution 0.01, 0.1mg/L, optional
        DO calibrate 1 point
        Temperature compensation range 0~50 ℃, 32~ 122 ° F, Automatic
        Pressure compensation range 60.0~112.5kPa, 450~850mmHg
        Salinity compensation range 0~50g/L
        DO% Measurement range 0.0~200.0%
        DO% measurement Accuracy ±2.0%
        DO% resolution 0.1, 1%
        Data stability condition Fast or high precision
        Calibrated reminder 1 to 31 days or closed
        shutdown mode Manual or automatic (10, 20, 30 minutes after no button operation)
        data storage 500 groups
        Communication interface USB
        Connector 6-Pin MINI Connector
        Display Customized LCD (130 * 110mm)
        Power DC5V power adapter
        Dimensions 210*188*60mm
        Instrument Weight 1.5kg
        Optional accessories DO100 type dissolved Oxygen electrode, dissolved Oxygen electrode filling solution, dissolved Oxygen electrode film cap
        Packaging Dimensions 300*240*170mm
        Encasement Weight 1.7kg

        Bante Bante980 Laboratory Dissolved Oxygen Meter Packing list

        Host X1, DC5V power adapter X1, USB cable X1, dissolved Oxygen electrode film cap X1, dissolved Oxygen electrode filler X1, DO100 dissolved Oxygen electrode (made in the United States) X1, manual X1, certificate X1, warranty card X1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        To make a deoxygenated Resin, the final requirement is less than 10ppb, that is, less than 0.01mg/L. Is there a dissolved oxygen tester that can do it?
        [A]
        Not easy to measure, the lower limit measured by this electrode is 0.02mg/L
        [Q]
        Can I buy the electrolysis solution in the Bante980 dissolved oxygen meter separately?
        [A]
        OK
        [Q]
        Is this dissolved oxygen meter convenient for measurement? Is it easy to calibrate?
        [A]
        Hello, the dissolved oxygen tester is generally not difficult to operate. You can first take a look at the operation manual of the experimental dissolved oxygen tester, which is relatively simple and convenient.
        Bante
        Bante980 laboratory Dissolved Oxygen Meter
        Service
        Focus on online sales of Lab Testing Instruments