BANTE A181 Precision dissolved oxygen/BOD/OUR/SOUR meter
Precision Dissolved Oxygen Meter, 1 or 2 point calibrated, 1000 sets of data storage, the instrument is suitable for laboratory determination of dissolved oxygen concentration and percentage saturation of samples, Measurement accuracy: 0.2mg/L.
Bante-
LEICI 780800N09 Hexavalent Chromium Reagent Kit for DGB-404F
$ 158.00 -
YUEFENG SZ8126 multiparameter water quality Tester, supports 10 parameters
$ 895.00 -
Bante60 portable intelligent Dissolved Oxygen Meter dissolved oxygen BOD OUR SOUR
$ 607.00 -
LEICI DZS-706F multiparameter analyzer
$ 1100.00 -
DDKSIC TEMP-01 Temperature electrode BNC (Q6) conventional aqueous solution
$ 101.00
A181 Precision Dissolved Oxygen Meter
Precision Dissolved Oxygen Meter, 1 or 2 point key calibration, 1000 sets of data storage, the instrument is suitable for laboratory determination of dissolved oxygen concentration and percentage saturation of samples, measurement accuracy: 0.2mg/L.
pH mode features:
• Precision Dissolved Oxygen Meter with 7-inch TFT display.
• 1 or 2 point pushbutton calibration using air saturated water or zero oxygen liquid.
• Salinity and atmospheric pressure compensation to ensure accurate measurement within the full range.
• Automatic temperature compensation to eliminate measurement deviations at different temperatures.

Dissolved Oxygen Meter
• Alarm limit, automatically warns if the measured value exceeds the set range.
• Stability icon to indicate meter measurement status.
• Automatic end point locking, retaining stable measurement values for easy viewing and recording.
• Interval reading mode, regularly send measured values to PC or printer.
• Password protection to prevent unauthorized calibration and settings.
• Expanded memory can store up to 1000 sets of data.
• USB communication interface is easy to connect external devices.
• One key reset (Reset) automatically restores the instrument to the factory default settings.
Bante A181 Precision dissolved oxygen/BOD/OUR/SOUR meterSpecifications
| LIST | VALUE |
|---|---|
| DO range | 0.00~20.00mg/L |
| DO measurement Accuracy | ±0.2mg/L |
| DO resolution | 0.01mg/L |
| DO calibrate | 1 or 2 point |
| Temperature compensation range | 0~50 ℃, 32~ 122 ° F, Automatic |
| Pressure compensation range | 60.0~112.5kPa, 450~850mmHg |
| Salinity compensation range | 0~50g/L |
| DO% Measurement range | 0.0~200.0% |
| DO% measurement Accuracy | ±2.0% |
| DO% resolution | 0.1% |
| Data stability condition | Standard or high precision |
| Calibrated reminder | 1 to 31 days or closed |
| data storage | 1000 groups |
| Communication interface | USB |
| Connector | 6-Pin MINI Connector |
| Display | 7-Inch TFT LCD |
| Power | DC12V power adapter |
| Dimensions | 240*220*80mm |
| Instrument Weight | 1.7kg |
| Optional accessories | DO100 type dissolved Oxygen electrode, dissolved Oxygen electrode filling solution, dissolved Oxygen electrode film cap |
| Packaging Dimensions | 300*240*170mm |
| Encasement Weight | 2kg |
| Interval reading | 10, 30, 60 seconds, 10, 30 minutes or off |
Bante A181 Precision dissolved oxygen/BOD/OUR/SOUR meter Packing list
Host X1, DC12V power adapter X1, dissolved Oxygen electrode film cap X1, dissolved Oxygen electrode filler X1, DO100 dissolved Oxygen electrode (made in the United States) X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJF 1714-2018
- ActiveJJF 1565-2016
- ActiveJJF 1441-2013
- ActiveJJG 2104-2024
- Active 096-2007
- ActiveSC/T 7006-2001
- AbolishGB/T 12157-2007
- ActiveGB/T 20245.4-2013
- ActiveGB/T 12157-2022
- ActiveGB/T 1576-2018
- ActiveHJ 2515-2012


A181
A180