Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> STIP-scan> Bante> Bante Bante900-CN Laboratory multiparaMeter Water Quality Meter
      Bante Bante900-CN Laboratory multiparaMeter Water Quality Meter

      Bante900-CN laboratory multiparameter Water Quality Meter

      High-precision multiparameter Water Quality Analyzer, including 8 measurement functions, 15 function parameters can be customized in the setting menu, the meter is suitable for laboratory measurement of pH, ORP, Ion concentration, conductivity, TDS, salinity, resistivity, dissolved oxygen concentration and saturation

      Brand
      SKU: NB014822
      China Bante
      VS
      Genuinegoods
      • Bante Bante900-CN Laboratory multiparaMeter Water Quality MeterOverview

      • Specifications
      • Comments
      • FAQs
      Bante900-CN
      Laboratory multiparaMeter Water Quality Meter
      • Bante900-CN laboratory multiparameter Water Quality Meter
      High-precision multiparameter Water Quality Analyzer, including 8 measurement functions, 15 function parameters can be customized in the setting menu, the meter is suitable for laboratory measurement of pH, ORP, Ion concentration, conductivity, TDS, salinity, resistivity, dissolved oxygen concentration and saturation

      Bante900 multi-parameter Water Quality Analyzer

      Multi-parameter laboratory TDS meter with built-in system menu, 15 functional parameters to choose from, the instrument is suitable for measuring pH, redox potential, ion concentration, conductivity, total dissolved solids (TDS), salinity, resistivity, dissolved oxygen concentration and saturation of liquids.

      pH Mode Features

      • Multi-parameter Water Quality Analyzer with large backlit LCD screen.

      • 1 to 5 point push-button calibration for automatic recognition of pH standard buffers.

      • Optional pH buffer standard (USA/NIST/DIN) or 2-point custom calibration.

      • Automatic electrode slope display to prompt the user whether to change the pH electrode.

      ORP mode features:

      • 1-point offset calibration that allows adjustment of the display value to a known standard.

      • Relative and absolute mV modes provide accurate ORP readings.

      Ion Mode Features

      • 2 to 5 pushbutton calibration, including 8 concentration calibration points.

      • Automatic identification of ion-selective electrodes without the need to specify the ion type.

      • Direct reading of ion concentration values to avoid tedious conversions and calculations.

      • Concentration units (ppm, mg/L, mol/L) are available to meet a variety of ion measurement needs.

      TDS meter

      TDS meter

      Conductivity/TDS/Salinity/Resistivity Mode Features

      • 1 to 5 point key calibration for automatic identification of conductivity standards.

      • Selectable cell constant (K=0.1/1/10), TDS conversion factor, normalized temperature (20 or 25°C), linear and pure water temperature compensation,

        Seawater and practical salinity measurement mode.

      Dissolved Oxygen Mode Features

      • 1 or 2 button calibration, using air saturated water or zero oxygen solution.

      • Salinity and atmospheric pressure compensation to improve the measurement accuracy of the instrument.

      General features:

      • Automatic temperature compensation for accurate measurements over the full scale.

      • Automatic calibration reminder to remind the user to calibrate the meter regularly.

      • Automatic endpoint locking, stable measured values are retained for easy browsing and recording.

      • Automatic electrode diagnostics with zero offset, electrode slope, range and conductivity K values.

      • The system menu can customize 15 functional parameters such as the number of calibration points, stability standard, data lock mode, automatic shutdown, etc.

      • One-key Reset automatically restores the meter to factory default settings.

      • Extended memory for up to 500 sets of measurement data.

      • Built-in clock automatically marks the date and time of stored data to comply with GLP specifications.

      • USB communication interface to send stored data to a personal computer.

      VS

      Bante Bante900-CN Laboratory multiparaMeter Water Quality MeterSpecifications

      LIST VALUE
      PH range -2.000~20.000pH
      Measurement Accuracy of pH ±0.002pH
      pH resolution 0.1, 0.01, 0.001 pH, optional
      pH calibrating point 1 to 5 point
      pH calibrating solution USA, NIST, DIN, Custom
      pH temperature compensation range 0~100℃, 32~212°F
      pH temperature compensation Manual/Automatic
      ORP Measurement range ±1999.9mV
      Measurement Accuracy of mV ±0.2mV
      mV resolution 0.1, 1mV, optional
      mV calibrated point 1 point (only for R.mV mode)
      mV calibrated range ±200mV
      Measurement range 0.001~ 19999ppm, mg/L, mol/L (please refer to the ionic electrode description for the actual range)
      Measurement Accuracy +/- 0.5% F. S (diion ), +/- 1% F. S (diion)
      Ion resolution 0.001, 0.01, 0.1, 1
      Ion calibrated point 2 to 5 point
      Ion calibrating fluid 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mol/L, mg/L
      Ion temperature compensation range 0~100℃, 32~212°F
      Ion temperature compensation Manual or automatic
      Conductivity range 0~20mS/cm (最大 200mS/cm)
      Measurement Accuracy of conductivity ±0.5%FS
      EC resolution 0.001, 0.01, 0.1, 1
      Conductivity calibrated point 1 to 5 point
      Conductivity calibrating fluid 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm
      EC Temperature Compensation Mode Manual or automatic
      EC Temperature Compensation Coefficient 0.0~10.0%/℃
      EC Temperature Compensation Mode mode Linear or pure water
      Conductivity Detector pool constant K = 0.1, 1, 10, custom
      Standardized temperature 20 ℃, 25 ℃, optional
      EC Temperature Compensation Range 0~100℃, 32~212°F
      TDS range 0~10ppt (maximum 200ppt)
      TDS Measurement Accuracy ±1%FS
      TDS conversion factor 0.1~ 1.0 (default 0.5)
      Salinity range 0~10ppt (maximum 80ppt)
      Measurement Accuracy of salinity ±1%FS
      Measurement mode of salinity Utility salinity (psu) or seawater salinity (ppt)
      Resistivity range 0 ~ 10MΩ (? 20MΩ)
      Resistivity range ±1% F.S
      Resistivity resolution 0.01, 0.1, 1
      DO range 0.00~20.00mg/L
      DO Measurement Accuracy ±0.2mg/L
      DOS resolution 0.1, 0.01 mg/L, optional
      DO temperature compensation range 0~50℃
      DO temperature compensation automatic
      Pressure compensation range 60.0~112.5kPa, 450~850mmHg
      Salinity compensation range 0~50g/L
      DO% Measurement range 0.0~200.0%
      DO% Measurement Accuracy ±2.0%
      DO% resolution 0.1%
      Measurement range 0~105℃, 32~221℉
      Measurement Accuracy ±0.5℃
      Temperature Resolution 0.1℃
      Temperature calibrating point 1 point
      Temperature unit ℃, ° F, optional
      Data stability condition Fast or high-precision
      Calibrated reminder 1 to 31 days or closed
      shutdown mode Manual or automatic (10, 20, 30 minutes after no button operation)
      Data storage 500 sets
      Communication interface USB
      Connector BNC, 6-pin MINI Connector
      Display Customized LCD screen (130 * 110mm)
      Power Supply DC5V power adapter
      Dimensions 210*188*60mm
      Instrument Weight 1.5kg
      Optional Accessories P11 type pH electrode, P11-LiCl type pH electrode, P11-HA type pH electrode, P11-NA type pH electrode
      Optional Accessories P12 type pH electrode, P13 type pH electrode, P15 type pH electrode, P16 type P22 type pH electrode
      Optional Accessories 501 type ORP electrode, 502 type ORP electrode, DO100 type dissolved Oxygen electrode, CON-10 type Conductivity Detector electrode, CON-0.1 type Conductivity Detector electrode, CON-1 type Conductivity Detector electrode,
      Optional Accessories NO3-US nitrate ion electrode, Ca-US calcium ion selective electrode, F-US fluoride ion selective electrode, Na-US sodium ion selective electrode, CL-US chloride ion selective electrode, CL-US chloride ion selective electrode,
      Optional Accessories Pb-US lead ion selective electrode, I-US iodine ion selective electrode, Cu-US copper ion selective electrode, Cd-US cadmium ion selective electrode, Br-US bromine ion selective electrode, NH4-US ammonium ion selective electrode, Cn-US cyanide ion selective electrode,
      Optional Accessories NH3-US Ammonia Gas sensing electrode, S-US sulfur ion selective electrode, Ag-US silver ion selective electrode, K-US potassium ion selective electrode, S-US sulfur ion selective electrode,
      Optional Accessories TP-10K temperature probe, dissolved Oxygen electrode membrane cap, dissolved Oxygen electrode filling solution, Conductivity Detector standard solution, ion standard solution, ion strength adjuster, pH standard buffer reagent (USA standard), pH standard buffer reagent (NIST standard)
      Packaging Dimensions 300*240*170mm
      Encasement Weight 1.7kg

      Bante Bante900-CN Laboratory multiparaMeter Water Quality Meter Packing list

      Host X1, E201-BNC type pH electrode X1, Con-1 type Conductivity detector electrode X1, DO100 type dissolved Oxygen electrode (made in the United States) X1, TP-10K type temperature probe X1, pH standard buffer reagent (pH4.01/7.00/10.01) X1, Conductivity detector standard solution (84uS/cm, 1413uS/cm, 12.88mS/cm) X1, dissolved Oxygen electrode filling solution X1, dissolved Oxygen electrode film cap X1, USB cable X1, DC5V power adapter X1, manual X1, certificate X1, warranty card X1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      What does the screen display PURE mean?
      [A]
      It refers to the pure water compensation mode.
      [Q]
      Conductivity detector electrode how to clean stains?
      [A]
      Immerse the electrode Sensors in tap water for 10 minutes to remove oil or stains that may be attached to the Platinum Sensors.
      [Q]
      How to calibrate STIP-scan temperature?
      [A]
      Specific operations: 1. Ensure that the temperature probe is connected to the meter; 2. Press and hold the ℃ key for 3 seconds, the meter enters the temperature calibrate mode, and the screen displays the current temperature value; 3. Press up or down to set the temperature value; 4. Press the enter key to confirm, the calibrate is complete.
      [Q]
      The screen displays --- what is the reason?
      [A]
      There are two possible reasons: 1. The electrode Sensors are too drying, which can be solved by immersing in tap water for 10 minutes; 2. Measured value Excessive range: Check whether the Sensors are clean and not contaminated.
      Bante
      Bante900-CN laboratory multiparameter Water Quality Meter
      Service
      Focus on online sales of Lab Testing Instruments