      Bante Bante900-UK Laboratory multiparameter Water Quality Meter

      Bante900-UK laboratory multiparameter Water Quality Meter

      Multiparameter laboratory TDS meter, built-in system menu, 15 function parameters optional, the meter is suitable for measurement of liquid pH, Oxidation-reduction potential, Ion concentration, conductivity, total dissolved solids (TDS), salinity, resistivity, dissolved oxygen concentration and saturation.

      Brand
      SKU: NB014823
      China Bante
      Stock
      Loading…
      Price
      $ 876.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • Bante Bante900-UK Laboratory multiparameter Water Quality MeterOverview

        • Specifications
        • Comments
        • FAQs
        Bante900-UK
        Laboratory multiparameter Water Quality Meter
        • Bante900-UK laboratory multiparameter Water Quality Meter
        Multiparameter laboratory TDS meter, built-in system menu, 15 function parameters optional, the meter is suitable for measurement of liquid pH, Oxidation-reduction potential, Ion concentration, conductivity, total dissolved solids (TDS), salinity, resistivity, dissolved oxygen concentration and saturation.

        Bante900 multi-parameter Water Quality Analyzer

        Multi-parameter laboratory TDS meter with built-in system menu, 15 functional parameters to choose from, the instrument is suitable for measuring pH, redox potential, ion concentration, conductivity, total dissolved solids (TDS), salinity, resistivity, dissolved oxygen concentration and saturation of liquids.

        pH Mode Features

        • Multi-parameter Water Quality Analyzer with large backlit LCD screen.

        • 1 to 5 point push-button calibration for automatic recognition of pH standard buffers.

        • Optional pH buffer standard (USA/NIST/DIN) or 2-point custom calibration.

        • Automatic electrode slope display to prompt the user whether to change the pH electrode.

        ORP mode features:

        • 1-point offset calibration that allows adjustment of the display value to a known standard.

        • Relative and absolute mV modes provide accurate ORP readings.

        Ion Mode Features

        • 2 to 5 pushbutton calibration, including 8 concentration calibration points.

        • Automatic identification of ion-selective electrodes without the need to specify the ion type.

        • Direct reading of ion concentration values to avoid tedious conversions and calculations.

        • Concentration units (ppm, mg/L, mol/L) are available to meet a variety of ion measurement needs.

        TDS meter

        TDS meter

        Conductivity/TDS/Salinity/Resistivity Mode Features

        • 1 to 5 point key calibration for automatic identification of conductivity standards.

        • Selectable cell constant (K=0.1/1/10), TDS conversion factor, normalized temperature (20 or 25°C), linear and pure water temperature compensation,

          Seawater and practical salinity measurement mode.

        Dissolved Oxygen Mode Features

        • 1 or 2 button calibration, using air saturated water or zero oxygen solution.

        • Salinity and atmospheric pressure compensation to improve the measurement accuracy of the instrument.

        General features:

        • Automatic temperature compensation for accurate measurements over the full scale.

        • Automatic calibration reminder to remind the user to calibrate the meter regularly.

        • Automatic endpoint locking, stable measured values are retained for easy browsing and recording.

        • Automatic electrode diagnostics with zero offset, electrode slope, range and conductivity K values.

        • The system menu can customize 15 functional parameters such as the number of calibration points, stability standard, data lock mode, automatic shutdown, etc.

        • One-key Reset automatically restores the meter to factory default settings.

        • Extended memory for up to 500 sets of measurement data.

        • Built-in clock automatically marks the date and time of stored data to comply with GLP specifications.

        • USB communication interface to send stored data to a personal computer.

        VS

        Bante Bante900-UK Laboratory multiparameter Water Quality MeterSpecifications

        LIST VALUE
        PH range -2.000~20.000pH
        Measurement Accuracy of pH ±0.002pH
        pH resolution 0.1, 0.01, 0.001 pH, optional
        pH calibrating point 1 to 5 point
        pH calibrating solution USA, NIST, DIN, Custom
        pH temperature compensation range 0~100℃
        pH temperature compensation Manual/Automatic
        ORP Measurement range ±1999.9mV
        mV Measurement Accuracy ±0.2mV
        mV resolution 0.1/1 mV, optional
        mV calibrated point 1 point (only for R.mV mode)
        mV calibrated range ±200mV
        Measurement range 0.001~ 19999ppm, mg/L, mol/L (please refer to the ionic electrode description for the actual range)
        Measurement Accuracy +/- 0.5% F. S (diion ), +/- 1% F. S (diion)
        Ion resolution 0.001, 0.01, 0.1, 1
        Ion calibrated point 2 to 5 point
        Ion calibrating fluid 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mol/L, mg/L
        Ion temperature compensation range 0~100℃, 32~212°F
        Ion temperature compensation Manual or automatic
        Conductivity range 0~20mS/cm (max. 200mS/cm)
        Measurement Accuracy of conductivity ±0.5%FS
        EC resolution 0.001, 0.01, 0.1, 1
        Conductivity calibrated point 1 to 5 point
        Conductivity calibrating fluid 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm
        EC Temperature Compensation Mode Manual or automatic
        EC Temperature Compensation Coefficient 0.0~10.0%/℃
        EC Temperature Compensation Mode mode Linear or pure water
        Conductivity Detector cell constant K = 0.1, 1, 10, custom
        Standardized temperature 20 ℃, 25 ℃, optional
        EC Temperature Compensation Range 0~100℃, 32~212°F
        TDS range 0~10ppt (max 200ppt)
        TDS Measurement Accuracy ±1%FS
        TDS conversion factor 0.1~ 1.0 (default 0.5)
        Salinity range 0~10ppt (maximum 80ppt)
        Measurement Accuracy of salinity ±1%FS
        Measurement mode of salinity Utility salinity (psu) or seawater salinity (ppt)
        Resistivity range 0~10MΩ (up to 20MΩ)
        Resistivity range ±1% F.S
        Resistivity resolution 0.01, 0.1, 1
        DO range 0.00~20.00mg/L
        DO Measurement Accuracy ±0.2mg/L
        DOS resolution 0.1, 0.01 mg/L, optional
        DO temperature compensation range 0~50℃
        DO temperature compensation automatic
        Pressure compensation range 60.0~112.5kPa, 450~850mmHg
        Salinity compensation range 0~50g/L
        DO% Measurement range 0.0~200.0%
        DO% Measurement Accuracy ±2.0%
        DO% resolution 0.1%
        Measurement range 0~105℃, 32~221℉
        Measurement Accuracy ±0.5℃
        Temperature Resolution 0.1℃
        Temperature calibrating point 1 point
        Temperature unit ℃, ° F, optional
        Data stability condition Fast or high-precision
        Calibrated reminder 1 to 31 days or closed
        shutdown mode Manual or automatic (10, 20, 30 minutes after no button operation)
        Data storage 500 sets
        Communication interface USB
        Connector BNC, 6-pin MINI Connector
        Display Customized LCD screen (130 * 110mm)
        Power Supply DC5V power adapter
        Dimension 210*188*60mm
        instrument Weight 1.5kg
        Optional Accessories P11 type pH electrode, P11-LiCl type pH electrode, P11-HA type pH electrode, P11-NA type pH electrode
        Optional Accessories P12 type pH electrode, P13 type pH electrode, P15 type pH electrode, P16 type P22 type pH electrode
        Optional Accessories Type 501 ORP electrode, Type 502 ORP electrode, DO100 dissolved Oxygen electrode, CON-10 type Conductivity Detector electrode, CON-0.1 type Conductivity Detector electrode, CON-1 type Conductivity Detector electrode,
        Optional Accessories NO3-US nitrate ion electrode, Ca-US calcium ion selective electrode, F-US fluoride ion selective electrode, Na-US sodium ion selective electrode, CL-US chloride ion selective electrode, CL-US chloride ion selective electrode,
        Optional Accessories Pb-US lead ion selective electrode, I-US iodine ion selective electrode, Cu-US copper ion selective electrode, Cd-US cadmium ion selective electrode, Br-US bromine ion selective electrode, NH4-US ammonium ion selective electrode, Cn-US cyanide ion selective electrode,
        Optional Accessories NH3-US Ammonia Gas sensing electrode, S-US sulfur ion selective electrode, Ag-US silver ion selective electrode, K-US potassium ion selective electrode, S-US sulfur ion selective electrode,
        Optional Accessories TP-10K temperature probe, dissolved Oxygen electrode membrane cap, dissolved Oxygen electrode filling solution, Conductivity Detector standard solution, ion standard solution, ion strength adjuster, pH standard buffer reagent (USA standard), pH standard buffer reagent (NIST standard)
        Packaging Dimensions 300*240*170mm
        Encasement Weight 1.7kg

        Bante Bante900-UK Laboratory multiparameter Water Quality Meter Packing list

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        How to choose the ion mode of water quality measurement instrument?
        [A]
        This ion-selective electrode automatically recognizes the ion type.
        [Q]
        How to configure pH standard buffer?
        [A]
        The steps of configuring the standard buffer solution include: 1. Take the pH7.00 standard buffer tank reagent and pour it into the volumetricflask; 2. Add 250ml of distillation water to the volumetricflask, and stir the solution until the reagent is completely dissolved.
        [Q]
        What electrode is connected to the REF behind the instrument?
        [A]
        This is used to connect the reference electrode.
        [Q]
        How to calibrate STIP-scan temperature?
        [A]
        Specific operations: 1. Ensure that the temperature probe is connected to the meter; 2. Press and hold the ℃ key for 3 seconds, the meter enters the temperature calibrate mode, and the screen displays the current temperature value; 3. Press up or down to set the temperature value; 4. Press the enter key to confirm, the calibrate is complete.
        [Q]
        What is the range of laboratory STIP-scan pH measurement?
        [A]
        Measurement range is -2.000~ 20.000 pH.
        Bante
        Bante900-UK laboratory multiparameter Water Quality Meter
        Service
        Focus on online sales of Lab Testing Instruments