      Home> STIP-scan> Bante> Bante Bante901-CN Precision pH/Conductivity Meter

      Bante901-CN Precision pH/Conductivity Meter Fish Pond STIP-scan

      With CHINA electrode, pH Measurement range -2.000~20.000pH, conductivity Measurement range 0~20mS/cm, Automatic temperature compensation, Automatic calibration reminder.

      Brand
      SKU: NB014824
      China Bante
      VS
      Information
      Genuinegoods
      • Bante Bante901-CN Precision pH/Conductivity MeterOverview

      • Specifications
      • Comments
      • FAQs
      Bante901-CN
      Precision pH/Conductivity Meter
      • Bante901-CN Precision pH/Conductivity Meter Fish Pond STIP-scan
      • Bante901-CN Precision pH/Conductivity Meter Fish Pond STIP-scan Figure 1
      With CHINA electrode, pH Measurement range -2.000~20.000pH, conductivity Measurement range 0~20mS/cm, Automatic temperature compensation, Automatic calibration reminder.

      Bante901 Precision pH/Conductivity Meter

      Multi-parameter laboratory pH meter, including 4 measurement functions, 12 functional parameters can be customized in the built-in system menu, the meter is suitable for measuring pH, mV, conductivity and total dissolved solids (TDS) value of liquids.

      pH mode features:

      • Multi-parameter Water Quality Analyzer with large backlit LCD display.

      • 1 to 5 point key calibration, automatic identification of pH standard buffer.

      • Optional pH buffer standard (USA/NIST/DIN) or 2-point custom calibration.

      • Automatic electrode slope display, prompting the user whether to replace the pH electrode.

      Conductivity/TDS mode features:

      • 1 to 5 point key calibration, automatic identification of conductivity standard solution.

      • Optional cell constant (K=0.1/1/10), TDS conversion factor, normalized temperature (20 or 25°C), linear and pure water temperature compensation modes.

      laboratory pH meter

      laboratory pH meter

      General features:

      • Automatic temperature compensation to ensure accurate measurement over the full range.

      • Automatic Calibration Reminder to remind users to calibrate the meter on a regular basis.

      • Automatic end point locking, retaining stable measurement values for easy viewing and recording.

      • Automatic electrode diagnosis, you can check the zero offset, electrode slope and conductivity K value.

      • The system menu can customize 12 functional parameters such as the number of calibration points, stability standard, data lock mode, and automatic shutdown.

      • One key reset (Reset) automatically restores the instrument to the factory default settings.

      • Expanded memory can store up to 500 sets of measurement data.

      • The built-in clock automatically marks the date and time of stored data to comply with GLP regulations.

      • USB communication interface to send stored data to PC.

      VS

      Bante Bante901-CN Precision pH/Conductivity MeterSpecifications

      LIST VALUE
      pH Measurement range -2.000~20.000pH
      pH measurement Accuracy ±0.002pH
      pH resolution 0.1, 0.01, 0.001pH, optional
      pH calibrating point 1 to 5 point
      pH calibrating solution USA, NIST, DIN, custom
      pH temperature compensation range 0~100°C, 32~212°F
      pH temperature compensation Manual/Automatic
      ORP Measurement range ±1999.9mV
      mV measurement Accuracy ±0.2mV
      mV resolution 0.1, 1mV, optional
      Conductivity Detector Measurement range 0~20mS/cm (最大 200mS/cm)
      电导率Accuracy ±0.5%FS
      Conductivity Detector resolution 0.001, 0.01, 0.1, 1
      Conductivity Detector calibrated point 1 to 5 point
      Conductivity Detector using calibrating fluid 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm
      Temperature compensation range 0~100℃, 32~212°F
      Temperature compensation method Manual or automatic
      temperature compensation coefficient 0.0~10.0%/°C
      Temperature compensation mode Linear or pure water
      Conductivity Detector cell constant K = 0.1, 1, 10, custom
      Standardized temperature 20 ℃, 25 ℃, optional
      TDS range 0 to 10ppt (up to 200ppt)
      TDSAccuracy ±1%FS
      TDS conversion factor 0.1~ 1.0 (default 0.5)
      Temperature Measurement range 0~105℃, 32~221℉
      Temperature measurement Accuracy ±0.5℃
      temperature resolution 0.1℃
      Temperature calibrating point 1 point
      Temperature unit ℃, ° F, optional
      Data stability condition Fast or high precision
      Calibrated reminder 1 to 31 days or closed
      shutdown mode Manual or automatic (10, 20, 30 minutes after no button operation)
      data storage 500 groups
      Communication interface USB
      Connector BNC, 6-pin MINI Connector
      Display Customized LCD (130 * 110mm)
      Power DC5V power adapter
      Dimensions 210*188*60mm
      Instrument Weight 1.5kg
      Optional accessories P11 type pH electrode, P11-LiCl type pH electrode, P11-HA type pH electrode, P11-NA type pH electrode,
      Optional accessories P12 type pH electrode, P13 type pH electrode, P15 type pH electrode, P16 type pH electrode, P18 type pH electrode, P19 type pH electrode, P21 type pH electrode, P22 type pH electrode,
      Optional accessories Type 501 ORP electrode, Type 502 ORP electrode, CON-0.1 electrode, Conductivity Detector standard solution, pH standard buffer reagent (USA standard), pH standard buffer reagent (NIST standard), TP-10K temperature probe
      Packaging Dimensions 300*240*170mm
      Encasement Weight 1.7kg

      Bante Bante901-CN Precision pH/Conductivity Meter Packing list

      Host X1, E201-BNC type pH electrode X1, Con-1 type Conductivity detector electrode X1, TP-10K type temperature probe X1, pH standard buffer reagent (pH4.01/7.00/10.01) X1, Conductivity detector standard solution (84uS/cm, 1413uS/cm, 12.88mS/cm) X1, USB cable X1, DC5V power adapter X1, manual X1, certificate X1, warranty card X1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      How to calibrate STIP-scan temperature?
      [A]
      Specific operations: 1. Ensure that the temperature probe is connected to the meter; 2. Press and hold the ℃ key for 3 seconds, the meter enters the temperature calibrate mode, and the screen displays the current temperature value; 3. Press up or down to set the temperature value; 4. Press the enter key to confirm, the calibrate is complete.
      [Q]
      The screen displays --- what is the reason?
      [A]
      There are two possible reasons: 1. The electrode Sensors are too drying, which can be solved by immersing in tap water for 10 minutes; 2. Measured value Excessive range: Check whether the Sensors are clean and not contaminated.
      [Q]
      Hello, I would like to ask what is the difference between these two (901-CN and 901-UK)?
      [A]
      Hello, the electrodes of these two models are different. -CN is equipped with a domestic (CN) electrode -UK is equipped with imported electrodes
      Bante