      Home> STIP-scan> Bante> Bante Bante902-CN MultiparaMeter Water Quality Analyzer

      Bante902-CN Precision pH/conductivity /TDS/salinity/resistivity meter

      Simultaneously detect pH, conductivity, TDS, salinity, with China electrode, automatic temperature compensation, calibrated reminder, end point locking, support 500 sets of measurement data.

      Brand
      SKU: NB014826
      China Bante
      VS
      Information
      Genuinegoods
      • Bante Bante902-CN MultiparaMeter Water Quality AnalyzerOverview

      • Specifications
      • Comments
      • FAQs
      Bante902-CN
      MultiparaMeter Water Quality Analyzer
      • Bante902-CN Precision pH/conductivity /TDS/salinity/resistivity meter
      • Bante902-CN Precision pH/conductivity /TDS/salinity/resistivity meter Figure 1
      • Bante902-CN Precision pH/conductivity /TDS/salinity/resistivity meter Figure 2
      Simultaneously detect pH, conductivity, TDS, salinity, with China electrode, automatic temperature compensation, calibrated reminder, end point locking, support 500 sets of measurement data.

      Bante902 Precision pH/Conductivity/TDS/Salinity Meter

      Multi-parameter laboratory pH meter, including 6 measurement functions, built-in system menu can customize 12 functional parameters, the meter is suitable for measuring liquid pH, redox potential, conductivity, total dissolved solids, salinity and resistivity values .

      pH mode features:

      • Multi-parameter Water Quality Analyzer with large backlit LCD display.

      • 1 to 5 point key calibration, automatic identification of pH standard buffer.

      • Optional pH buffer standard (USA/NIST/DIN) or 2-point custom calibration.

      • Automatic electrode slope display, prompting the user whether to replace the pH electrode.

      ORP mode features:

      • 1-point offset calibration, allowing adjustment of displayed values to known standards.

      • Relative and absolute mV modes provide accurate ORP readings.

      laboratory pH meter

      laboratory pH meter

      Conductivity/TDS/salinity/resistivity mode features:

      • 1 to 5 point key calibration, automatic identification of conductivity standard solution.

      • Selectable cell constant (K=0.1/1/10), TDS conversion factor, normalized temperature (20 or 25°C), linear and pure water temperature compensation, seawater and practical salinity measurement modes.

      General features:

      • Automatic temperature compensation to ensure accurate measurement over the full range.

      • Automatic Calibration Reminder to remind users to calibrate the meter on a regular basis.

      • Automatic end point locking, retaining stable measurement values for easy viewing and recording.

      • Automatic electrode diagnosis, you can check the zero offset, electrode slope and conductivity K value.

      • The system menu can customize 12 functional parameters such as the number of calibration points, stability standard, data lock mode, and automatic shutdown.

      • One key reset (Reset) automatically restores the instrument to the factory default settings.

      • Expanded memory can store up to 500 sets of measurement data.

      • The built-in clock automatically marks the date and time of stored data to comply with GLP regulations.

      • USB communication interface to send stored data to PC.

      VS

      Bante Bante902-CN MultiparaMeter Water Quality AnalyzerSpecifications

      LIST VALUE
      Measurement range of pH -2.000~20.000pH
      Measurement Accuracy of pH ±0.002pH
      Measurement Accuracy of pH 0.1, 0.01, 0.001 pH, optional
      pH calibrating point 1 to 5 points
      pH calibrating solution USA, NIST, DIN, Custom
      pH temperature compensation range 0~100℃
      pH temperature compensation Manual/Automatic
      ORP Measurement range ±1999.9mV
      mV Measurement Accuracy ±0.2mV
      mV resolution 0.1/1 mV, optional
      mV calibrating point 1 point (for R.mV mode only)
      mV calibrated range ±200mV
      EC Measurement range 0~ 20mS/cm (max. 200mS/cm)
      EC Measurement Accuracy ±0.5%FS
      EC resolution 0.001, 0.01, 0.1, 1
      EC calibrating point 1 to 5 points
      Use calibrating fluid 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm
      EC temperature compensation range 0~100℃, 32~212°F
      EC temperature compensation Manual or automatic
      EC temperature compensation coefficient 0.0~10.0%/℃
      EC temperature compensation mode Linear or pure water
      Conductivity Detector cell constant K = 0.1, 1, 10, custom
      Standardized temperature 20 ℃, 25 ℃, optional
      TDS Measurement range 0~ 10ppt (max 200ppt)
      TDS Measurement Accuracy ±1%FS
      TDS conversion factor 0.1~ 1.0 (default 0.5)
      Measurement range of salinity 0~ 10ppt (maximum 80ppt)
      Measurement Accuracy of salinity ±1%FS
      Measurement mode of salinity Utility salinity (psu) or seawater salinity (ppt)
      Measurement range of resistivity 0~ 10MΩ (up to 20MΩ)
      Measurement Accuracy of resistivity ±1%FS
      Resistivity resolution 0.01, 0.1, 1
      Measurement range 0~105℃, 32~221℉
      Measurement Accuracy ±0.5℃
      Temperature Resolution 0.1℃
      Temperature calibrating point 1 point
      Temperature unit ° C, ° F, optional
      Data stability condition Fast or high-precision
      Calibrated reminder 1 to 31 days or closed
      shutdown mode Manual or automatic (10, 20, 30 minutes after no button operation)
      Data storage 500 sets
      Communication interface USB
      Connector BNC, 6-pin MINI Connector
      Display Customized LCD screen (130 * 110mm)
      Power Supply DC5V power adapter
      Dimension 210*188*60mm
      instrument Weight 1.5kg
      Optional Accessories P19 type pH electrode, P18 type pH electrode, P16 type pH electrode, P15 type pH electrode, P13 type pH electrode, P12 type pH electrode, P11 type pH electrode, P11-LiCl type pH electrode, P11 type pH electrode, P11-NA type pH electrode,
      Optional Accessories TP-10K temperature probe, pH standard buffer reagent (NIST standard), pH standard buffer reagent (USA standard), Conductivity Detector standard solution, CON-10 type Conductivity Detector electrode, CON-1 type Conductivity Detector electrode, CON-0.1 type Conductivity Detector electrode, P21 type pH electrode, P22 type pH electrode, 501 type ORP electrode, 502 type ORP electrode
      Packaging Dimensions 300*240*170mm
      Encasement Weight 1.7kg

      Bante Bante902-CN MultiparaMeter Water Quality Analyzer Packing list

      Host X1, Conductivity detector standard solution (84 µS/cm, 1413 µS/cm, 12.88mS/cm) X1, E201-BNC pH electrode X1, Con-1 Conductivity detector electrode X1, TP-10K temperature probe X1, DC5V power adapter X1, USB cable X1, Conductivity detector standard solution (84 µS/cm, 1413 µS/cm, 12.88mS/cm) X1, manual X1, certificate X1, warranty card X1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      The screen displays --- what is the reason?
      [A]
      There are two possible reasons: 1. The electrode Sensors are too drying, which can be solved by immersing in tap water for 10 minutes; 2. Measured value Excessive range: Check whether the Sensors are clean and not contaminated.
      [Q]
      Can the BANTE Bante902-CN resistivity meter meet the ASTMD 5682-95 standard?
      [A]
      Applicable, please consult the customer service of the mall for details about the ASTMD 5682-95 standard.
      Bante
      Bante902-CN Precision pH/conductivity /TDS/salinity/resistivity meter
      Service
      Focus on online sales of Lab Testing Instruments