      Home> STIP-scan> Bante> Bante Bante904-CN Precision pH/conductivity /TDS/salinity/resistivity Meter

      Bante904-CN Precision pH/conductivity /TDS/salinity/resistivity meter

      CHINA electrode, while detecting pH, conductivity, TDS, salinity, resistivity, automatic temperature compensation, calibrating reminder, end point locking, electrode diagnosis.

      Brand
      SKU: NB014830
      China Bante
      VS
      Genuinegoods
      • Bante Bante904-CN Precision pH/conductivity /TDS/salinity/resistivity MeterOverview

      • Specifications
      • Comments
      • FAQs
      Bante904-CN
      Precision pH/conductivity /TDS/salinity/resistivity Meter
      • Bante904-CN Precision pH/conductivity /TDS/salinity/resistivity meter
      • Bante904-CN Precision pH/conductivity /TDS/salinity/resistivity meter Figure 1
      CHINA electrode, while detecting pH, conductivity, TDS, salinity, resistivity, automatic temperature compensation, calibrating reminder, end point locking, electrode diagnosis.

      Bante904 precision conductivity/TDS/salinity/Dissolved Oxygen Meter

      Multi-parameter laboratory TDS meter, including 5 measurement functions, built-in system menu can customize 13 function parameters, the meter is suitable for measuring liquid conductivity, total dissolved solids (TDS), salinity, resistivity, dissolved oxygen concentration and saturation.

      Conductivity/TDS/salinity/resistivity mode features:

      • Multi-parameter Water Quality Analyzer with large backlit LCD display.

      • 1 to 5 point key calibration, automatic identification of conductivity standard solution.

      • Selectable cell constant (K=0.1/1/10), TDS conversion factor, normalized temperature (20 or 25°C), linear and pure water temperature compensation,

        Seawater and practical salinity measurement modes.

      Functional characteristics of dissolved oxygen mode:

      • 1 or 2 point pushbutton calibration using air saturated water or zero oxygen liquid.

      • Compensation for salinity and atmospheric pressure to improve the measurement accuracy of the instrument.

      TDS meter

      TDS meter

      General features:

      • Automatic temperature compensation to ensure accurate measurement over the full range.

      • Automatic Calibration Reminder to remind users to calibrate the meter on a regular basis.

      • Automatic end point locking, retaining stable measurement values for easy viewing and recording.

      • Automatic electrode diagnosis, you can check the electrode slope value (K).

      • The system menu can customize 13 functional parameters such as the number of calibration points, stability standard, data lock mode, and automatic shutdown.

      • One key reset (Reset) automatically restores the instrument to the factory default settings.

      • Expanded memory can store up to 500 sets of measurement data.

      • The built-in clock automatically marks the date and time of stored data to comply with GLP regulations.

      • USB communication interface to send stored data to PC.

      VS

      Bante Bante904-CN Precision pH/conductivity /TDS/salinity/resistivity MeterSpecifications

      LIST VALUE
      Conductivity range 0~20mS/cm (max. 200mS/cm)
      Measurement Accuracy of conductivity ±0.5%FS
      EC resolution 0.001, 0.01, 0.1, 1
      Conductivity calibrated point 1 to 5 point
      Use calibrating fluid 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm
      EC Temperature Compensation Range 0~100℃, 32~212°F
      EC Temperature Compensation Mode Manual or automatic
      EC Temperature Compensation Coefficient 0.0~10.0%/℃
      EC Temperature Compensation Mode mode Linear or pure water
      Conductivity Detector cell constant K = 0.1, 1, 10, custom
      Standardized temperature 20 ℃, 25 ℃, optional
      TDS range 0~10ppt (max 200ppt)
      TDS Measurement Accuracy ±1%FS
      TDS conversion factor 0.1~ 1.0 (default 0.5)
      Salinity range 0~10ppt (max 80ppt)
      Measurement Accuracy of salinity ±1%FS
      Measurement mode of salinity Utility salinity (psu) or seawater salinity (ppt)
      Resistivity range 0~10MΩ (up to 20MΩ)
      Measurement Accuracy of resistivity ±1%FS
      Resistivity resolution 0.01, 0.1, 1
      DO range 0.00~20.00mg/L(ppm)
      DO Measurement Accuracy ±0.2mg/L
      DOS resolution 0.1, 0.01 mg/L, optional
      Temperature compensation range 0~50℃, 32~122°F
      Temperature compensation method automatic
      Pressure compensation range 60.0~112.5kPa, 450~850mmHg
      Salinity compensation range 0~50g/L
      Measurement range 0~105℃, 32~221℉
      Measurement Accuracy ±0.5℃
      Temperature Resolution 0.1℃
      Temperature calibrating point 1 point
      Temperature unit ℃, ° F, optional
      Data stability condition Fast or high-precision
      Calibrated reminder 1 to 31 days or closed
      shutdown mode Manual or automatic (10, 20, 30 minutes after no button operation)
      Data storage 500 sets
      Communication interface USB
      Connector 6-Pin MINI Connector
      Display Customized LCD screen (130 * 110mm)
      Power Supply DC5V power adapter
      Dimension 210*188*60mm
      instrument Weight 1.5kg
      Optional Accessories TP-10K temperature probe, dissolved Oxygen electrode film cap, dissolved Oxygen electrode filling solution, Conductivity Detector standard solution, CON-0.1 type Conductivity Detector electrode, CON-1 type Conductivity Detector electrode, CON-10 type Conductivity Detector electrode, DO100 type dissolved Oxygen electrode
      Packaging Dimensions 300*240*170mm
      Encasement Weight 1.7kg

      Bante Bante904-CN Precision pH/conductivity /TDS/salinity/resistivity Meter Packing list

      Host X1, Con-1 type Conductivity detector electrode X1, DO100 type dissolved Oxygen electrode (made in the United States) X1, TP-10K type temperature probe X1, Conductivity detector standard solution (84uS/cm, 1413uS/cm, 12.88mS/cm) X1, dissolved Oxygen electrode filling solution X1, dissolved Oxygen electrode film cap X1, USB cable X1, DC5V power adapter X1, manual X1, certificate X1, warranty card X1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Can the BANTE Bante904-CN resistivity meter meet the ASTMD 5682-95 standard?
      [A]
      Applicable, please consult the customer service of the mall for details about the ASTMD 5682-95 standard.
      Bante
      Bante904-CN Precision pH/conductivity /TDS/salinity/resistivity meter
      Service
      Focus on online sales of Lab Testing Instruments