Bante TB100 portable Turbidity Meter
High performance portable Turbidity Meter, 2 to 5 point calibrated, optional 4 Measurement units, instrument with single and continuous Measurement mode, suitable for process control and outdoor applications.
Bante-
Yuefeng SGZ-20B Portable Turbidity Meter 0~20NTU/0.01
$ 207.00 -
LEICI WZB-172 Turbidity Meter 850nm/500NTU
$ 700.00 -
LEICI WZT-701 Online turbidity monitor
$ 2681.00 -
HANNA HI88713 Microcomputer multi-range Turbidimeter (ISO standard)
$ 3124.00 -
Qiwei WGZ-200AS Microcomputer Turbidity Meter 0~1000NTU
$ 187.00
TB100 Portable Turbidimeter
High-performance portable Turbidimeter, 2 to 5-point calibration, 4 measurement units can be selected, the meter has single and continuous measurement modes, suitable for process control and outdoor applications.
Features
• Easy-to-use portable turbidimeter with standard carrying case.
• For 2 to 5 point calibration, use formazin standard solution.
• Optional 4 turbidity units, including NTU (Scattering Turbidity Units), FNU (Formazin Scattering Units), EBC (European Brewers
Association unit) and ASBC (American Brewers Association unit).
• Single measurement mode automatically determines stable readings.
• Continuous measurement mode can be used for indexing or pairing cuvettes.

Portable Turbidimeter
• Automatic power off, effectively saving battery power consumption.
• Built-in system menu, which can customize 7 functional parameters such as the number of calibration points, date and time, and display resolution.
• One-button reset, automatically restore the instrument to factory default settings.
• Expanded memory can store up to 100 sets of measurement data.
• USB communication interface to send stored data to PC.
• Multi-mode power supply scheme (power adapter, computer USB port) ensures the smooth application of the instrument.
Bante TB100 Portable Turbidity MeterSpecifications
| LIST | VALUE |
|---|---|
| Measurement method | ISO 7027 nephelometric method (90°) |
| Measuring range | 0 ~ 1100 NTU / FNU, 0 ~ 275EBC, 0 ~ 9999 ASBC |
| resolution | 0.01 (0~100 NTU), 0.1 (100~999 NTU), 1 (999~1100 NTU) |
| Accuracy | ±2% (0~500 NTU), ±3% (501~1100 NTU) |
| Default calibrated point | 0.02, 10.00, 200, 500, 1000 NTU |
| Light source/wavelength | Infrared Light Emitting Diodes |
| Receiving element | Silicon photoelectric receiver |
| stray light | < 0.02 NTU |
| Colorimetric bottle | 60 (H) × 25 (D) mm |
| shutdown mode | Manual or automatic (15 minutes after no button operation) |
| Data storage | 100 groups |
| Communication interface | USB |
| Operating temperature | 0~60°C |
| Power | 9V laminated battery 1 |
| Dimensions | 180*85*70mm |
| Instrument net Weight | 300g |
| Optional accessories | Suitable for TB series turbidity meter |
| Packaging Dimensions | 280 (L) × 230 (W) × 80 (H) mm |
| Encasement Weight | 1.5kg |
Bante TB100 Portable Turbidity Meter Packing list
host X1, sample bottle X1, standard liquid 0.02, 200, 500, 1000 NTUX1, flannel-free X1, 9V laminated battery X1, carrying case X1, manual X1, certificate X1, warranty card X1.
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.