XINRUI SD90715 Ammonia nitrogen analyzer, single parameter ion analyzer 0~10mg/L
XINRUI SD90715 Ammonia nitrogen analyzer The measurement range of the single-parameter ion analyzer is 0~10mg/L, and the minimum indication is 0.001mg/L. SD90715 ammonia nitrogen analyzer is a single-parameter ion analyzer using the principle of photoelectric Colorimetric detection.
XinRui-
JINGQI WD8209 Zinc Tester
$ 481.00 -
TONGAO TR 6900NH Benchtop Ammonia Nitrogen STIP-scan
$ 1439.00 -
QIWEI NS-1T desktop urea Detector measurement range 0-10mg/L
$ 298.00 -
JINGQI COD-5B Practical COD Speed Tester
$ 1316.00 -
HANNA HI7091L Oxidation-reduction potential calibrating solution (ORP) reduction pretreatment solution
$ 130.00
Overview of uses
Xinrui SD90715 Ammonia Nitrogen Analyzer The single-parameter ion analyzer uses the principle of photoelectric colorimetric detection instead of traditional visual colorimetry. Human error is eliminated and it has a high measurement resolution. When ions in the water react with a specific reagent, the water sample will rapidly change color. The water sample is then placed into the photoelectric custoire of the instrument, and the instrument compares the shades of the color to obtain the concentration value of the corresponding ion. It can be widely used in waterworks, industrial and mining enterprises, domestic (CN) or industrial water inspection departments, in order to control the ion concentration in the water to meet the specified water quality standards. This instrument conforms to the determination method of the national standard of GBT 5750-2006 Standard Test Method for Drinking Water.

Features
Microcomputer, touch keyboard, LCD display with backlight, new microprocessing technology and high-reliability integrated circuits.
It has the functions of data nonlinear processing and data smoothing, fast automatic multi-point correction, and self-diagnosis information prompt
It has a custom curve calibration function, and pre-stores high-precision full mathematical simulation working curves to ensure the accuracy of measurement data
Reliable positioning structure and special high-intensity and long-life light source, no maintenance, to ensure that the instrument can work stably for a long time
Integrating a number of independent design patent achievements, professional technology, stable work, and direct reading concentration value
XinRui SD90715 Ammonia nitrogen analyzerSpecifications
| LIST | VALUE |
|---|---|
| Measurement parameters | ammonia nitrogen |
| Measurement range | 0~10mg/L |
| Resolution | 0.001mg/L |
| Error of indication | ±5%FS |
| Repeatability | 2% |
| Power Supply | AC 220V/ 50Hz/5W |
XinRui SD90715 Ammonia nitrogen analyzer Packing list
host X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


SD90715