Overview of uses
SD9012B beer Colorimeter uses the principle of photoelectric colorimetry. The Hartong standard solution was used for calibration, and "EBC" was used as the unit of color measurement. Used for colorimetric measurement of beer and wort.

Features
Microcomputer system configuration, touch keyboard, standard serial RS232 communication interface, can be equipped with printers
LCD backlit LCD display for clear display of date, time, measured value and unit of measurement.
The calibration standard value can be set arbitrarily programmable, and the multi-point correction can be quickly and arbitrarily selected, and the 1-7 point automatic correction can be quickly and arbitrarily selected.
The built-in clock memory storage system can store measurement and calibration data in real time, and can store and recall the last 20 sets of measurement data for a long time.
It is equipped with a turbidity compensation system, which can effectively avoid the interference caused by suspended particles in the sample, and can correctly reflect the concept of chromaticity
Self-diagnosis information prompts, direct reading of EBC chromaticity values, 100,000 hours of long-life high-intensity light source, maintenance-free long-term use.
XinRui SD9012B Beer Turbidity MeterSpecifications
| LIST | VALUE |
|---|---|
| Display mode | digital explicit |
| Resolution | 0.01EBC |
| Measurement range | 0~30 EBC |
| Error of indication | 2~ 5 EBC ≤ +/- 0.25 EBC, 5~ 10 EBC ≤ +/- 0.5 EBC, 10~30 EBC ≤ +/- 1 EB C |
| Repeatability | ±1%F.S |
| Zero drift | ≤±0.05 EBC |
XinRui SD9012B Beer Turbidity Meter Packing list
host X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Why is silicone oil important in turbidity meter measurements?
- How to measure the turbidity of a liquid?
- 10 Tips for Using Turbidity Meters Correctly and Keeping Accurate Measurements
- ActiveJJF 1700-2018
- ActiveJJF 1571-2016
- ActiveHJ 1075-2019
- ActiveHJ 1075-2019
- ActiveGB/T 18570-2009
- ISO 15715-2003


SD9012B