      Home> Viscosity Cup> Moderner> Moderner CNDB-2 Zahn Viscosity Cup
      Moderner CNDB-2 Zahn Viscosity Cup

      MODERNER CNDB-2 Zahn Viscosity Cup (zahn cup) 2.7mm Zahn cup

      Viscosity range 20~230cSt, outflow time 20~80s, flow hole diameter 2.7mm, capacity 45ml, cup body material stainless steel, filter material stainless steel, handle material stainless steel, applicable standard ASTM D4212-93.

      Brand
      SKU: NB015113
      China Moderner
      Stock
      Loading…
      Price
      Please contact customer service
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • Moderner CNDB-2 Zahn Viscosity CupOverview

        • Specifications
        • Comments
        • FAQs
        CNDB-2
        Zahn Viscosity Cup
        • MODERNER CNDB-2 Zahn Viscosity Cup (zahn cup) 2.7mm Zahn cup
        Viscosity range 20~230cSt, outflow time 20~80s, flow hole diameter 2.7mm, capacity 45ml, cup body material stainless steel, filter material stainless steel, handle material stainless steel, applicable standard ASTM D4212-93.

        use

        Zahn Viscosity Cups are used to test the viscosity of Newtonian or near-Newtonian fluids. CNDB type Chai's Viscosity Cup is manufactured according to ASTM D4212-93 standard.

        Model Selection

        model

        Measuring range

        Recommended outflow time

        Aperture

        CNDB-1

        5-6035-802.0mm

        CNDB-2

        20-23020-802.7mm

        CNDB-3

        150-85020-803.8mm

        CNDB-4

        220-110020-804.3mm

        CNDB-5

        460-184020-805.3mm
        Unit: cSt, s, mm
        Other parameters
        volume

        45± 2ml


        zahn portable Viscosity Cup

        Use and maintenance

        1. Clean the cup body with a suitable solvent before and after use.

        2. Choose an appropriate cup number, and try to make the outflow time meet the recommended outflow time in the above table.

        3. Immerse the cup body in the container for 1 to 5 minutes to make the cup reach thermal equilibrium, then pull the cup vertically out of the raw material, and the action needs to be fast and steady. When the top edge of the cup leaves the liquid surface, keep the cup body vertical when the liquid flows, and the distance between the bottom of the cup and the liquid surface of the container should not exceed 150mm. Stop timing when the first breakpoint occurs, and the number of seconds of outflow time at this time indicates a certain viscosity value. The difference between the two measured values should be less than 5% of the average value.

        4. Convert the outflow time into kinematic viscosity according to the following formula: (sample temperature is 25°C±0.5°C when measuring)

            ν = k(t - c)

            In the formula: ν—kinematic viscosity, cSt

                   t — outflow time, s

                   k, c — corresponding constants (see table below)

        cup number

        1

        2

        3

        4

        5

        k

        1.1

        3.5

        11.7

        14.8

        twenty three

        c

        29

        14

        7.5

        5

        0

        VS

        Moderner CNDB-2 Zahn Viscosity CupSpecifications

        LIST VALUE
        Viscosity range 20~230cSt
        outflow time 20~80s
        flow hole diameter 2.7mm
        Capacity 45ml
        Cup body material stainless steel
        Filter material stainless steel
        Handle material stainless steel
        Applicable standard ASTM D4212-93
        Weight 0.5kg
        Packaging Dimensions Φ58×380mm

        Moderner CNDB-2 Zahn Viscosity Cup Packing list

        Viscosity cup × 1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        Which is the No. 2 cup of Shanghai environment engineering?
        [A]
        There are two kinds of modern No. 2 viscosity cups, including Zahn Cup and Ford viscosity cup.
        [Q]
        What range of viscosity is the CNDB-2 viscosity cup suitable for measurement?
        [A]
        The CNDB-2 Zahn viscosity cup is suitable for the measurement of viscosity in the range of 20-230 cSt, with a recommended outflow time of 20-80 seconds and a flow hole diameter of 2.7mm.
        [Q]
        What is the main purpose of this Zahn viscosity cup?
        [A]
        Zahn viscosity cup (Zahn cup) is used to test the viscosity of Newtonian or near-Newtonian fluids. This model is manufactured according to ASTM D4212-93 standard.
        [Q]
        How to convert the outflow time of CNDB Zahn viscosity cup to kinematic viscosity?
        [A]
        The kinematic viscosity (cSt) can be converted by the following formula: < unk > = k (t - c), where < unk > is the kinematic viscosity, t is the outflow time, and k and c are constants corresponding to the cup number (see table provided).
        [Q]
        The main use of CNDB Zahn viscosity cup?
        [A]
        CNDB Zahn viscosity cup is mainly used to test the viscosity of Newtonian or approximate Newtonian fluids.