MODERNER CNDB-4 Zahn Viscosity Cup (zahn cup) 4.3mm portable Zahn cup
Viscosity range 220~1100cSt, outflow time 20~80s, flow hole diameter 4.3mm, capacity 45ml, cup body material stainless steel, filter material stainless steel, handle material stainless steel, applicable standard ASTM D4212-93.
Moderner-
TRUIT TR 1002/5 Ford Viscosity Cup outflow aperture φ5.20mm
$ 125.00 -
British Sheen Ref. 417/6 Viscosity Cup aperture 6mm
$ 187.00 -
YONGLIDA FORD-3 Ford Viscosity Cup fluid second measuring cup
$ 161.00 -
Japan TOYO TOYO 2 #inks Viscosity Cup Coating Viscosity Cup Zahn Zahn Cup
$ 183.00 -
YONGLIDA FORD-1 Ford Viscosity Cup Paints Flow Cup
$ 161.00
use
Zahn Viscosity Cups are used to test the viscosity of Newtonian or near-Newtonian fluids. CNDB type Chai's Viscosity Cup is manufactured according to ASTM D4212-93 standard.
Model Selection
model | Measuring range | Recommended outflow time | Aperture |
CNDB-1 | 5-60 | 35-80 | 2.0mm |
CNDB-2 | 20-230 | 20-80 | 2.7mm |
CNDB-3 | 150-850 | 20-80 | 3.8mm |
CNDB-4 | 220-1100 | 20-80 | 4.3mm |
CNDB-5 | 460-1840 | 20-80 | 5.3mm |
| Unit: cSt, s, mm | |||
| Other parameters | |||
| volume | 45± 2ml | ||

Use and maintenance
1. Clean the cup body with a suitable solvent before and after use.
2. Choose an appropriate cup number, and try to make the outflow time meet the recommended outflow time in the above table.
3. Immerse the cup body in the container for 1 to 5 minutes to make the cup reach thermal equilibrium, then pull the cup vertically out of the raw material, and the action needs to be fast and steady. When the top edge of the cup leaves the liquid surface, keep the cup body vertical when the liquid flows, and the distance between the bottom of the cup and the liquid surface of the container should not exceed 150mm. Stop timing when the first breakpoint occurs, and the number of seconds of outflow time at this time indicates a certain viscosity value. The difference between the two measured values should be less than 5% of the average value.
4. Convert the outflow time into kinematic viscosity according to the following formula: (sample temperature is 25°C±0.5°C when measuring)
ν = k(t - c)
In the formula: ν—kinematic viscosity, cSt
t — outflow time, s
k, c — corresponding constants (see table below)
cup number | 1 | 2 | 3 | 4 | 5 |
k | 1.1 | 3.5 | 11.7 | 14.8 | twenty three |
c | 29 | 14 | 7.5 | 5 | 0 |
Moderner CNDB-4 Zahn Viscosity CupSpecifications
| LIST | VALUE |
|---|---|
| Viscosity range | 220~1100cSt |
| outflow time | 20~80s |
| Flow hole diameter | 4.3mm |
| Capacity | 45ml |
| Cup body material | stainless steel |
| Filter material | stainless steel |
| Handle material | stainless steel |
| Applicable standard | ASTM D4212-93 |
Moderner CNDB-4 Zahn Viscosity Cup Packing list
Viscosity cup × 1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Method for Determination of Coating Viscosity by Zain Cup
- Method for Determination of Coating Viscosity by Zein Viscosity Cup
- Active
- ReplacedASTM
- ActiveGB/T 13217.4-2020
- ActiveASTM D1084-2021
- ActiveJJG 743-2018
- ActiveASTM D4212-2016
- ReplacedJJG 743-1991
- AbolishGB/T 13217.4-2008


CNDB-4
CNDB-2
CNDB-1
CNDB-3
CNDB-5






