Defelsko F0S split 0 ° probe 1150 μm/+/- 1% for small parts, edge coating measurements
Defelsko F0S split 0 ° probe, Defelsko smallest measurement tip and good film Measurement accuracy, this probe is suitable for measurement of small parts, hard-to-reach areas or near the edge.
Defelsko-
LEEB leeb252 Coating Thickness Gauge magnetic Induction/eddy Current dual-use automatic identification substrate
Login -
TQC SP1111 Destructiveness Thickness Gauge Blade 1 Blade 20~2000μm Range
$ 271.00 -
LANDTEK CM8825Fn platings Thickness Measurement Instrument Dual function coating Thickness Measurement Instrument
$ 386.00 -
HT2916 Ultrasonic Coating thickness gauge Simultaneous measurement of multi-layer thickness, Non-metallic/metallic coating thickness
$ 1090.00 -
LANDTEK CM8825N Handheld Thickness Gauge Integrated Handheld Thickness Gauge
$ 309.00
Full range of probe details
Detachable built-in probe
F,N,FN,FT
Suitable for one-handed operation
| Detachable built-in probe | Probe model | F、N、FN | FT | ||
![]() | range | 0~60 mils | 0~250mils | ||
| 0~1500μm | 0~6mm/0~6000μm | ||||
| precision | + (0.05 mils + 1%) 0~2 mils + (0.1 mils + 1%) > 2 mils | + (0.5 mils + 1%) 0~100 mils + (0.5 mil + 3%) > 100 mils | |||
+ (1 um + 1%) 0~50 um + (2 um + 1%) > 50 um | + (0.01 mm + 1%) 0~2.5 mm + (0.01 mm + 3%) > 2.5 mm | ||||
| Accuracy is calculated by adding a fixed value to the percentage of readings | |||||

Split conventional probes
FS,NS,FNS,NAS,FTS
These constant-pressure, stainless steel probes are hermetically sealed and completely waterproof – ideal for underwater measurements.
| Regular | Probe model | FS、NS、FNS | NAS | FTS |
![]() | range | 0~60 mils | 0~25 mils | 0~250 mils |
| 0~1500 um | 0~625 um | 0~6 mm/0~6000 μm | ||
| precision | + (0.05 mils + 1%) 0~2 mils + (0.1 mils + 1%) > 2 mils | + (0.02 mils + 1%) 0~4 mils + (0.1 mils + 3%) > 4 mils | + (0.5 mils + 1%) 0~100 mils + (0.5 mil + 3%) > 100 mils | |
+ (1 um + 1%) 0~50 um + (2 um + 1%) > 50 um | + (.5 um + 1%) 0~100 um + (2 um + 3%) > 100 um | + (0.01 mm + 1%) 0~2.5 mm + (0.01 mm + 3%) > 2.5 mm | ||
| Accuracy is calculated by adding a fixed value to the percentage of readings | ||||

FXS Xtreme™
Uniquely designed for applications with rough surfaces. The measuring surface of the FXS Xtreme™ probe is a zirconia toughened alumina wear surface, which is ideal for measuring rough steel surfaces.
Increases the measurement speed to 50 readings per minute, making it suitable for fast measurement of large, rough surfaces. The scan mode increases the rate of measurement to more than 100 readings per minute. (Only PosiTector Premium models have a scan mode)
Compatible with PosiTector mainframes with serial numbers greater than 700,000 and the new Positector SmartLink.
| FXS Xtreme™ | ||
![]() | range | 0~1500 um |
| 0~60 mils | ||
| precision | + (0.05 mils + 1%) 0~2 mils + (0.1 mils + 1%) > 2 mils | |
+ (1 um + 1%) 0~50 um + (2 um + 1%) > 50 um | ||
| Accuracy is calculated by adding a fixed value to the percentage of readings | ||

Split 90° conventional probe
FRS,NRS,FNRS
Right-angle probes are suitable for measuring low headroom areas.
These constant-pressure, stainless steel probes are hermetically sealed and completely waterproof – ideal for underwater measurements
| 90° conventional type | Probe model | FRS、NRS、FNRS |
![]() | range | 0~60 mils |
| 0~1500 um | ||
| precision | + (0.05 mils + 1%) 0~2 mils + (0.1 mils + 1%) > 2 mils | |
+ (1 um + 1%) 0~50 um + (2 um + 1%) > 50 um | ||
| Accuracy is calculated by adding a fixed value to the percentage of readings | ||

FNDS
The PosiTector 6000 FNDS probe simultaneously measures the thickness of paint and zinc layers in a composite coating system in a single readout.
Composite coating systems use a combination of two corrosion protection systems – typically painted or powder coated on galvanized steel (thermal, electrical, or zinc-sprayed metal). resultantCorrosion protection due toanySeparate protection system.
In composite mode, the positector 6000 FNDS is usedmagnetic induction(ferrous) and eddy current (non-ferrous) principles that simultaneously calculate and display individual coating and zinc layer thicknesses. The magnetic induction principle is used to measure the total thickness of the lacquer/zinc layer on a ferrous substrate, while the eddy current Thickness Gauge principle is used to measure the thickness of the paint layer on a non-ferrous zinc layer. The zinc layer thickness is calculated by subtracting the thickness of the paint layer from the total lacquer/zinc layer thickness. The schematic diagram is as follows,

When not available, the gauge is like a traditional ferrous/non-ferrous dual-function gauge (similar topositector 6000 FNS probe). It is suitable for measuring the thickness of non-magnetic coatings on steel and non-conductive coatings on non-ferrous metal substrates.
Positicctor Advanced (serial number 730000+) and color LCD are compatible with the Positicctor standard gage. A simple Thickness Gauge update is required.
| FNDS | ||||
![]() | range | 0~60 mils/0~1500 um | ||
| Composite coating | Minimum zinc layer thickness | 0.5 mil (13 um) | ||
| Paint layer accuracy | Mils | + (0.05 mils + 1%) 0~2 mils + (0.1 mils + 1%) > 2 mils | ||
| μm | + (1 um + 1%) 0~50 um + (2 um + 1%) > 50 um | |||
| Zinc layer accuracy | Mils | + (0.1 mils + 1%) 0.5~2 mils + (0.2 mils + 1%) > 2 mils | ||
| μm | + (2 um + 1%) 13~50 um + (4 um + 1%) > 50 um | |||
| Accuracy is calculated by adding a fixed value to the percentage of readings | ||||
Split 0° probe
F0S,N0S
With a minimal measuring tip and very good thin-film measurement accuracy, this probe is suitable for measuring small parts, hard-to-reach areas or near edges.
The straight F0S and N0S miniature probes have a quick-release adapter that allows them to be targeted at a constant pressure on small, flat or curved parts. This adapter is designed on a spring, if you don't need a sleeve, simply unplug it from the probe.
| 0° miniature probe | Probe model | F0S | N0S |
![]() | range | 0~45 mils | 0~25 mils |
| 0~1150 um | 0~625 um | ||
| precision | + (0.02 mils + 1%) 0~4 mils + (0.1 mils + 3%) > 4 mils | ||
+ (0.5 um + 1%) 0~100 um + (2 um + 3%) > 100 um | |||
| Accuracy is calculated by adding a fixed value to the percentage of readings | |||

Split 45° miniature probe
F45S,N45S
With a minimal measuring tip and very good thin-film measurement accuracy, this probe is suitable for measuring small parts, hard-to-reach areas or near edges.
| 45° miniature probe | Probe model | F45S | N45S |
![]() | range | 0~45 mils | 0~25 mils |
| 0~1150 um | 0~625 um | ||
| precision | + (0.02 mils + 1%) 0~4 mils + (0.1 mils + 3%) > 4 mils | ||
+ (0.5 um + 1%) 0~100 um + (2 um + 3%) > 100 um | |||
| Accuracy is calculated by adding a fixed value to the percentage of readings | |||

Split 90° miniature probe
F90S,N90S
Right-angle probes are suitable for measuring low headroom areas.
With a minimal measuring tip and very good thin-film measurement accuracy, this probe is suitable for measuring small parts, hard-to-reach areas or near edges.
| 90° miniature probe | Probe model | F90S | N90S |
![]() | range | 0~45 mils | 0~25 mils |
| 0~1150 um | 0~625 um | ||
| precision | + (0.02 mils + 1%) 0~4 mils + (0.1 mils + 3%) > 4 mils | ||
+ (0.5 um + 1%) 0~100 um + (2 um + 3%) > 100 um | |||
| Accuracy is calculated by adding a fixed value to the percentage of readings | |||

Wide-range probes
FT,FTS,FNTS,FKS,NKS
Suitable for thick coatings such as epoxy resin, rubber, cement, intumescent fire retardant coatings, etc.
| Large-scale type | Probe model | FT,FTS,FNTS | FKS,NKS | ||
![]() | ![]() | ![]() | range | 0~250 mils | 0~500 mils |
| 0~6 mm/0~6000 μm | 0~13 mm/0~500 mils | ||||
| precision | + (0.5 mils + 1%) 0~100 mils + (0.5 mil + 3%) > 100 mils | + (1 mils + 3%) + (0.02 mm + 3%) | |||
+ (0.01 mm + 1%) 0~2.5 mm + (0.01 mm + 3%) > 2.5 mm | |||||
| FT | FTS | FNTS,FKS,NKS | Accuracy is calculated by adding a fixed value to the percentage of readings | ||
FHXS Xtreme
Measure non-conductive coatings on steel substrates
The FHXs Xtreme probe comes with alumina, abrasion-resistant contact surfaces and braided cables for use on hot or rough surfaces. Hot surface temperatures can be as high as 250°C (500°F).
Compatible with PosiTector mainframes with serial numbers greater than 700,000 and the new Positector SmartLink.
| FHXS Xtreme | ||
![]() | range | 0~400 mils |
| 0~10000 um | ||
| precision | + (0.1 mils + 3%) | |
+ (2 um + 3%) | ||
| Accuracy is calculated by adding a fixed value to the percentage of readings | ||

FLS
Suitable for measuring intumescent varnish and other thick protective coatings on steel.
● Measure thickness up to 38mm (1.5 inches)
● Braided stainless steel cable - torsion-resistant, abrasion-resistant, shear-resistant
● Includes hard case and 19 mm (750 mil) spacer
Compatible with PosiTector mainframes with serial numbers greater than 700,000 and the new Positector SmartLink.
| FLS | ||
![]() | range | 0~38 mm |
| 0~1.5inch | ||
| precision | + (0.01 in. + 3%) | |
| + (0.2 mm + 3%) | ||
| Minimum surface area | 3.25 x 3.25 inches (83 x 83 mm) | |
| Minimum substrate thickness | 0.1inch(2.5 mm) | |
| Accuracy is calculated by adding a fixed value to the percentage of readings | ||

FNGS
Suitable for measuring very thick coatings on all metals. It is particularly suitable for measuring hull coatings and thick intumescent coatings.
● Measure thicknesses up to 63.5 mm (2.5 inches)
● Measure the thickness of non-conductive coatings on magnetic and non-magnetic metal substrates.
● Braided stainless steel cable - torsion-resistant, abrasion-resistant, shear-resistant
● Long-lasting, low-wear probe contact for easy scanning of large areas.
● Includes a handle for easy one-handed operation
● Includes a set of traceable coating thickness standards
● Instruction cards are included
Compatible with PosiTector mainframes with serial numbers greater than 700,000 and the new Positector SmartLink.
| FLS | ||
Probe weight: 0.8kg | range | 0~63.5 mm |
| 0~2.5inch | ||
| precision | + (0.01" + 3%) | |
| + (0.2 mm + 3%) | ||
| Minimum surface area | 10 x 10 inches (254x254 mm) | |
| Minimum substrate thickness | 0.2inch(2.5 mm) | |
| Accuracy is calculated by adding a fixed value to the percentage of readings | ||
Probe Purchase Chart
F – Ironsubstrate(Steel & Cast Iron)
N - NonIronmetalsubstrate(Aluminum, copper, titanium, etc.)
FN – All metal substrates – automatic identification of substrates
| Probe model | substrate | Probe type | Measuring range |
| F | Iron | Movable built-in | 0~60 mils (0~1500 um) |
| FS | Iron | Conventional cables | 0~60 mils (0~1500 um) |
| FXS Xtreme™ | Iron | routinecable | 0~60 mils (0~1500 um) |
| FRS | Iron | 90° conventional cable | 0~60 mils (0~1500 um) |
| F0S | Iron | 0° miniature probe | 0~45 mils (0~1150 um) |
| F45S | Iron | 45° miniature probe | 0~45 mils (0~1150 um) |
| F90S | Iron | 90° miniature probe | 0~45 mils (0~1150 um) |
| FT | Iron | Movable built-in | 0~250 mils (0~6 mm) |
| FTS | Iron | A wide range of cables | 0~250 mils (0~6 mm) |
| FKS | Iron | A wide range of cables | 0~500 mils (0~13 mm) |
| FHXS Xtreme™ | Iron | A wide range of cables | 0~400 mils (0~10000 um) |
| FLS | Iron | A wide range of cables | 0~1.5 inches (0~38 mm) |
| N | notIron | Movable built-in | 0~60 mils (0~1500 um) |
| NS | notIron | Conventional cables | 0~60 mils (0~1500 um) |
| NRS | notIron | 90° conventional cable | 0~60 mils (0~1500 um) |
| NAS | notIron | Conventional cables | 0~25 mils (0~625 um) |
| N0S | notIron | 0° miniature probe | 0~25 mils (0~625 um) |
| N45S | notIron | 45° miniature probe | 0~25 mils (0~625 um) |
| N90S | notIron | 90° miniature probe | 0~25 mils (0~625 um) |
| NKS | notIron | A wide range of cables | 0~500 mils (0~13 mm) |
| FN | Iron/notIron | Movable built-in | 0~60 mils (0~1500 um) |
| FNS | Iron/notIron | Conventional cables | 0~60 mils (0~1500 um) |
| FNRS | Iron/notIron | 90° conventional cable | 0~60 mils (0~1500 um) |
| FNDS (duplex) | Iron/notIron | Conventional cables | 0~60 mils (0~1500 um) |
| FNTS | Iron/notIron | A wide range of cables | 0~250 mils (0~6 mm) |
| FNGS | Iron/notIron | A wide range of cables | 0~2.5 inches (0~63.5 mm) |
Defelsko PRBF0S-D Thickness Gauge probeSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | Magnetic Induction |
| Measurement range | 0~1150μm |
| margin of error | ±1% |
| Resolution | 0.1μm |
| probe | 6000 F0S Cabled Probe |
| Probe size | Φ5mm |
| Calibrated Certificate | Yes. |
| compatible model | PosiTector |
Defelsko PRBF0S-D Thickness Gauge probe Packing list
Probe x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- New: Defelsko PosiTest CH cross-cut adhesion Tester
- Application scheme of coating thickness test on wood board [with test video]
- Curved plastic coating thickness test application scheme [with test video]
- PosiTector200C ultrasonic coating Thickness Gauge on concrete coating thickness measurement application
- Defelsko PosiTector 200 Ultrasonic coating Thickness Gauge Chinese version Instructions for use [2023 new version]
- Appearance evolution of Defelsko coating Thickness Gauge to see the progress of industrial testing instruments
- Defelsko PosiTector 6000 coating Thickness Gauge Chinese version Instructions for use [2023 new version]
- Calibration Terms - Coating Thickness Gages
- Application of Defelsko PosiTest OTL furnace temperature Recorder in curing index testing
- Measure gloss with a PosiTector GLS gloss meter
- ActiveHG/T 3240-2007
- ActiveQJ 990.3A-2011
- ActiveGB/T 7991.5-2014
- ActiveJJG 818-2018
- ActiveGB/T 1727-2021
- ActiveHG/T 20720-2020
- ActiveSY/T 0315-2013
- ActiveISO 2178-2016
- ActiveASTM B499-2021
- ActiveISO 19840-2012
- ASTM E376-2019
- ActiveISO 2808-2019
- AbolishJJG 889-1995
- ActiveGB/T 4956-2003
- ISO 6158-1984
- ISO 2361-1982
- ActiveGB/T 6463-2005
- AbolishGB/T 4956-1985
- AbolishASTM G12-07-2013
- ActiveJB/T 7217-2008


PRBF0S-D