      Home> Coating Thickness Gauge> Defelsko> Defelsko FHXS Xtreme™ Thickness Gauge probe
      Defelsko FHXS Xtreme™ Thickness Gauge probe

      Defelsko FHXS Xtreme ™ probe for high temperature or rough coating

      FHXs Xtreme probes with aluminum oxide abrasion-resistant contact surfaces and braided cables for hot or rough surfaces. Hot surface temperatures up to 250 ℃ (500 ° F). Compatible with PosiTector hosts with serial numbers greater than 700000 and the new Positector SmartLink.

      Brand
      SKU: NB015157
      United States Defelsko
      VS
      Information
      Genuinegoods
      • Defelsko FHXS Xtreme™ Thickness Gauge probeOverview

      • Specifications
      • Comments
      • FAQs
      FHXS Xtreme™
      Thickness Gauge probe
      • Defelsko FHXS Xtreme ™ probe for high temperature or rough coating
      FHXs Xtreme probes with aluminum oxide abrasion-resistant contact surfaces and braided cables for hot or rough surfaces. Hot surface temperatures up to 250 ℃ (500 ° F). Compatible with PosiTector hosts with serial numbers greater than 700000 and the new Positector SmartLink.


      Full range of probe details

      The Defelsko PosiTector 6000 Coating Thickness Gauge has a detachable built-in probe diagram Detachable built-in probe

      F,N,FN,FT


      Suitable for one-handed operation




      Detachable built-in probeProbe modelF、N、FNFT
      Defelsko PosiTector 6000 Coating Thickness Gauge Detachable Internal Probe Dimensional Drawingrange0~60 mils0~250mils
      0~1500μm0~6mm/0~6000μm
      precision

      + (0.05 mils + 1%)  0~2 mils

      + (0.1 mils  +  1%)  > 2 mils

      + (0.5 mils + 1%)  0~100 mils

      + (0.5 mil + 3%) > 100 mils

      + (1 um + 1%)  0~50 um

      + (2 um + 1%)  > 50 um

      + (0.01 mm + 1%) 0~2.5 mm

      + (0.01 mm + 3%) > 2.5 mm

      Accuracy is calculated by adding a fixed value to the percentage of readings


      Defelsko PosiTector 6000 Series Coating Thickness Gauge Split Conventional Transducer

      Split conventional probes

      FS,NS,FNS,NAS,FTS


      These constant-pressure, stainless steel probes are hermetically sealed and completely waterproof – ideal for underwater measurements.



      RegularProbe modelFS、NS、FNSNASFTS
      Dimension drawing of the Defelsko PosiTector 6000 Series Coating Thickness Gauge Split Conventional Transducerrange0~60 mils0~25 mils0~250 mils
      0~1500 um0~625 um0~6 mm/0~6000 μm
      precision

      + (0.05 mils + 1%)  0~2 mils

      + (0.1 mils  +  1%)  > 2 mils

      + (0.02 mils + 1%)  0~4 mils

      + (0.1 mils + 3%)  > 4 mils

      + (0.5 mils + 1%)  0~100 mils

      + (0.5 mil + 3%) > 100 mils

      + (1 um + 1%)  0~50 um

       + (2 um + 1%)  > 50 um

      + (.5 um + 1%)  0~100 um

       + (2 um + 3%)  > 100 um 

       + (0.01 mm + 1%) 0~2.5 mm

      + (0.01 mm + 3%) > 2.5 mm

      Accuracy is calculated by adding a fixed value to the percentage of readings


      Defelsko PosiTector 6000 Series Coating Thickness Gauge FXS Xtreme Probe

      FXS Xtreme™


      Uniquely designed for applications with rough surfaces. The measuring surface of the FXS Xtreme™ probe is a zirconia toughened alumina wear surface, which is ideal for measuring rough steel surfaces.

      Increases the measurement speed to 50 readings per minute, making it suitable for fast measurement of large, rough surfaces. The scan mode increases the rate of measurement to more than 100 readings per minute. (Only PosiTector Premium models have a scan mode)

      Compatible with PosiTector mainframes with serial numbers greater than 700,000 and the new Positector SmartLink.



      FXS Xtreme™
      Defelsko PosiTector 6000 Series Coating Thickness Gauge FXS Xtreme Probe Dimensional Drawingrange0~1500 um
      0~60 mils
      precision

      + (0.05 mils + 1%)  0~2 mils

      + (0.1 mils  +  1%)  > 2 mils

      + (1 um + 1%)  0~50 um

      + (2 um + 1%)  > 50 um

      Accuracy is calculated by adding a fixed value to the percentage of readings


      Defelsko PosiTector 6000 Series Coating Thickness Gauge Split 90℃onventional Transducer

      Split 90° conventional probe

      FRS,NRS,FNRS

      Right-angle probes are suitable for measuring low headroom areas.

      These constant-pressure, stainless steel probes are hermetically sealed and completely waterproof – ideal for underwater measurements



      90° conventional typeProbe modelFRS、NRS、FNRS
      Defelsko PosiTector 6000 Series Coating Thickness Gauge Split 90℃onventional Transducer Dimension Drawingrange0~60 mils
      0~1500 um
      precision

      + (0.05 mils + 1%)  0~2 mils

      + (0.1 mils  +  1%)  > 2 mils

      + (1 um + 1%)  0~50 um

      + (2 um + 1%)  > 50 um

      Accuracy is calculated by adding a fixed value to the percentage of readings


      Defelsko PosiTector 6000 Series Coating Thickness Gauge FNDS Probes

      FNDS

      The PosiTector 6000 FNDS probe simultaneously measures the thickness of paint and zinc layers in a composite coating system in a single readout.

      Composite coating systems use a combination of two corrosion protection systems – typically painted or powder coated on galvanized steel (thermal, electrical, or zinc-sprayed metal). resultantCorrosion protection due toanySeparate protection system.

      In composite mode, the positector 6000 FNDS is usedmagnetic induction(ferrous) and eddy current (non-ferrous) principles that simultaneously calculate and display individual coating and zinc layer thicknesses. The magnetic induction principle is used to measure the total thickness of the lacquer/zinc layer on a ferrous substrate, while the eddy current Thickness Gauge principle is used to measure the thickness of the paint layer on a non-ferrous zinc layer. The zinc layer thickness is calculated by subtracting the thickness of the paint layer from the total lacquer/zinc layer thickness. The schematic diagram is as follows,

      The PosiTector 6000 FNDS probe measures the decomposition intent of lacquer-zinc composite coatings

      When not available, the gauge is like a traditional ferrous/non-ferrous dual-function gauge (similar topositector 6000 FNS probe). It is suitable for measuring the thickness of non-magnetic coatings on steel and non-conductive coatings on non-ferrous metal substrates.

      Positicctor Advanced (serial number 730000+) and color LCD are compatible with the Positicctor standard gage. A simple Thickness Gauge update is required.

      FNDS
      Defelsko PosiTector 6000 Series Coating Thickness Gauge FNDS Probe Dimensional Drawingrange0~60 mils/0~1500 um
      Composite coatingMinimum zinc layer thickness0.5 mil (13 um)
      Paint layer accuracyMils

      + (0.05 mils + 1%)  0~2 mils

      + (0.1 mils  +  1%)  > 2 mils

      μm

      + (1 um + 1%)  0~50 um

       + (2 um + 1%)  > 50 um

      Zinc layer accuracyMils

      + (0.1 mils + 1%)  0.5~2 mils

      + (0.2 mils  +  1%)  > 2 mils

      μm

      + (2 um + 1%)  13~50 um

       + (4 um + 1%)  > 50 um

      Accuracy is calculated by adding a fixed value to the percentage of readings


      Diagram of the Defelsko PosiTector 6000 Coating Thickness Gauge Split 0° ProbeSplit 0° probe

      F0S,N0S

      With a minimal measuring tip and very good thin-film measurement accuracy, this probe is suitable for measuring small parts, hard-to-reach areas or near edges.

      The straight F0S and N0S miniature probes have a quick-release adapter that allows them to be targeted at a constant pressure on small, flat or curved parts. This adapter is designed on a spring, if you don't need a sleeve, simply unplug it from the probe.

      0° miniature probeProbe modelF0SN0S
      Dimension drawing of the Defelsko PosiTector 6000 Coating Thickness Gauge Split 0° Proberange0~45 mils0~25 mils
      0~1150 um0~625 um
      precision

      + (0.02 mils + 1%)  0~4 mils

      + (0.1 mils + 3%)  > 4 mils

      + (0.5 um + 1%)  0~100 um

      + (2 um + 3%)  > 100 um 

      Accuracy is calculated by adding a fixed value to the percentage of readings


      Diagram of the Defelsko PosiTector 6000 Coating Thickness Gauge Split 0° Probe

      Split 45° miniature probe

      F45S,N45S

      With a minimal measuring tip and very good thin-film measurement accuracy, this probe is suitable for measuring small parts, hard-to-reach areas or near edges.



      45° miniature probeProbe modelF45SN45S
      Dimension drawing of the Defelsko PosiTector 6000 Coating Thickness Gauge Split 45° Proberange0~45 mils0~25 mils
      0~1150 um0~625 um
      precision

      + (0.02 mils + 1%)  0~4 mils

      + (0.1 mils + 3%)  > 4 mils

      + (0.5 um + 1%)  0~100 um

      + (2 um + 3%)  > 100 um 

      Accuracy is calculated by adding a fixed value to the percentage of readings


      Diagram of the Defelsko PosiTector 6000 Coating Thickness Gauge Split 90° Micro Probe

      Split 90° miniature probe

      F90S,N90S

      Right-angle probes are suitable for measuring low headroom areas.

      With a minimal measuring tip and very good thin-film measurement accuracy, this probe is suitable for measuring small parts, hard-to-reach areas or near edges.



      90° miniature probeProbe modelF90SN90S
      Dimension drawing of the Defelsko PosiTector 6000 Coating Thickness Gauge Split 90° Miniature Proberange0~45 mils0~25 mils
      0~1150 um0~625 um
      precision

      + (0.02 mils + 1%)  0~4 mils

      + (0.1 mils + 3%)  > 4 mils

      + (0.5 um + 1%)  0~100 um

      + (2 um + 3%)  > 100 um 

      Accuracy is calculated by adding a fixed value to the percentage of readings


      Defelsko PosiTector 6000 Coating Thickness Gauge Large Range Probe

      Wide-range probes

      FT,FTS,FNTS,FKS,NKS


      Suitable for thick coatings such as epoxy resin, rubber, cement, intumescent fire retardant coatings, etc.



      Large-scale typeProbe modelFT,FTS,FNTSFKS,NKS
      Defelsko PosiTector 6000 Coating Thickness Gauge FT Probe, USADefelsko PosiTector 6000 Coating Thickness Gauge FTS Probe Size DrawingDefelsko PosiTector 6000 Coating Thickness Gauge FNTS, FKS, NKS Transducer Size Drawingrange0~250 mils0~500 mils

      0~6 mm/0~6000 μm0~13 mm/0~500 mils
      precision

      + (0.5 mils + 1%)  0~100 mils

      + (0.5 mil + 3%) > 100 mils

      + (1 mils + 3%) 

      + (0.02 mm + 3%) 

      + (0.01 mm + 1%) 0~2.5 mm

      + (0.01 mm + 3%) > 2.5 mm

      FTFTSFNTS,FKS,NKSAccuracy is calculated by adding a fixed value to the percentage of readings


      Defelsko PosiTector 6000 Coating Thickness Gauge FHXS Xtreme ProbeFHXS Xtreme

      Measure non-conductive coatings on steel substrates


      The FHXs Xtreme probe comes with alumina, abrasion-resistant contact surfaces and braided cables for use on hot or rough surfaces. Hot surface temperatures can be as high as 250°C (500°F).

      Compatible with PosiTector mainframes with serial numbers greater than 700,000 and the new Positector SmartLink.



      FHXS Xtreme
      Defelsko PosiTector 6000 Coating Thickness Gauge FHXS Xtreme probe size drawingrange0~400 mils
      0~10000 um
      precision

      + (0.1 mils + 3%) 

      + (2 um + 3%)

      Accuracy is calculated by adding a fixed value to the percentage of readings


      Defelsko PosiTector 6000 Coating Thickness Gauge FLS probe diagram

      FLS

      Suitable for measuring intumescent varnish and other thick protective coatings on steel.

      ● Measure thickness up to 38mm (1.5 inches)

      ● Braided stainless steel cable - torsion-resistant, abrasion-resistant, shear-resistant

      ● Includes hard case and 19 mm (750 mil) spacer

      Compatible with PosiTector mainframes with serial numbers greater than 700,000 and the new Positector SmartLink.



      FLS
      Defelsko PosiTector 6000 Coating Thickness Gauge FLS Probe Size Drawingrange0~38 mm
      0~1.5inch
      precision+ (0.01 in. + 3%)
      + (0.2 mm + 3%)
      Minimum surface area3.25 x 3.25 inches (83 x 83 mm)
      Minimum substrate thickness0.1inch(2.5 mm)
      Accuracy is calculated by adding a fixed value to the percentage of readings


      Defelsko PosiTector 6000 Coating Thickness Gauge FNGS Probe Size Drawing

      FNGS

      Suitable for measuring very thick coatings on all metals. It is particularly suitable for measuring hull coatings and thick intumescent coatings.

      ● Measure thicknesses up to 63.5 mm (2.5 inches)

      ● Measure the thickness of non-conductive coatings on magnetic and non-magnetic metal substrates.

      ● Braided stainless steel cable - torsion-resistant, abrasion-resistant, shear-resistant

      ● Long-lasting, low-wear probe contact for easy scanning of large areas.

      ● Includes a handle for easy one-handed operation

      ● Includes a set of traceable coating thickness standards

      ● Instruction cards are included

      Compatible with PosiTector mainframes with serial numbers greater than 700,000 and the new Positector SmartLink.

      FLS

      Defelsko PosiTector 6000 Coating Thickness Gauge FNGS Probe Size Drawing

      Probe weight: 0.8kg

      range0~63.5 mm
      0~2.5inch
      precision+ (0.01" + 3%)
      + (0.2 mm + 3%)
      Minimum surface area10 x 10 inches (254x254 mm)
      Minimum substrate thickness0.2inch(2.5 mm)
      Accuracy is calculated by adding a fixed value to the percentage of readings

      Probe Purchase Chart

      F – Ironsubstrate(Steel & Cast Iron)

      N - NonIronmetalsubstrate(Aluminum, copper, titanium, etc.)

      FN – All metal substrates – automatic identification of substrates

      Probe modelsubstrateProbe typeMeasuring range
      FIronMovable built-in0~60 mils (0~1500 um)
      FSIronConventional cables0~60 mils (0~1500 um)
      FXS Xtreme™Ironroutinecable0~60 mils (0~1500 um)
      FRSIron90° conventional cable0~60 mils (0~1500 um)
      F0SIron0° miniature probe0~45 mils (0~1150 um)
      F45SIron45° miniature probe0~45 mils (0~1150 um)
      F90SIron90° miniature probe0~45 mils (0~1150 um)
      FTIronMovable built-in0~250 mils (0~6 mm)
      FTSIronA wide range of cables0~250 mils (0~6 mm)
      FKSIronA wide range of cables0~500 mils (0~13 mm)
      FHXS Xtreme™IronA wide range of cables0~400 mils (0~10000 um)
      FLSIronA wide range of cables0~1.5 inches (0~38 mm)
      NnotIronMovable built-in0~60 mils (0~1500 um)
      NSnotIronConventional cables0~60 mils (0~1500 um)
      NRSnotIron90° conventional cable0~60 mils (0~1500 um)
      NASnotIronConventional cables0~25 mils (0~625 um)
      N0SnotIron0° miniature probe0~25 mils (0~625 um)
      N45SnotIron45° miniature probe0~25 mils (0~625 um)
      N90SnotIron90° miniature probe0~25 mils (0~625 um)
      NKSnotIronA wide range of cables0~500 mils (0~13 mm)
      FNIron/notIronMovable built-in0~60 mils (0~1500 um)
      FNSIron/notIronConventional cables0~60 mils (0~1500 um)
      FNRSIron/notIron90° conventional cable0~60 mils (0~1500 um)
      FNDS (duplex)Iron/notIronConventional cables0~60 mils (0~1500 um)
      FNTSIron/notIronA wide range of cables0~250 mils (0~6 mm)
      FNGSIron/notIronA wide range of cables0~2.5 inches (0~63.5 mm)


      VS

      Defelsko FHXS Xtreme™ Thickness Gauge probeSpecifications

      LIST VALUE
      Measurement principle Magnetic Induction
      Measurement range 0~10000μm
      margin of error ±3%
      Resolution 0.1μm
      probe 6000 FHXS Cabled Probe
      Probe size Φ21mm
      Calibrated Certificate Yes.
      compatible model PosiTector

      Defelsko FHXS Xtreme™ Thickness Gauge probe Packing list

      Probe x1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Can the PosiTector 6000 measure coatings on hot surfaces?
      [A]
      The PosiTector 6000 FXS and FHXS Xtreme probes are ideal for measurement of Coating thickness on hot and/or rough surfaces (up to 250 ° C, 500 ° F). All PosiTector 6000 Coating thickness probes are capable of measurement on hot surfaces. Standard probe models can operate in environments up to 50 ° C (120 ° F). However, thickness measurements can be made at higher temperatures if the probe is lifted off the surface and chilled down immediately after reading. Just make sure the probe is kept below 50 ° C (120 ° F) and at a sufficient temperature for unprotected hand operation.
      +Defelsko FHXS Xtreme™ Thickness Gauge probe Big data
        +Defelsko FHXS Xtreme™ Thickness Gauge probeSimilar products
        +Defelsko FHXS Xtreme™ Thickness Gauge probeKnowledge
        +Defelsko FHXS Xtreme™ Thickness Gauge probeStandard
        +Navigation
        Defelsko
        Defelsko FHXS Xtreme ™ probe for high temperature or rough coating
        Service
        Focus on online sales of Lab Testing Instruments