Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Coating Thickness Gauge> Defelsko> Defelsko PRBN45S-D Thickness Gauge probe
      Defelsko PRBN45S-D Thickness Gauge probe

      Defelsko N45S split 45 ° micro probe, thin coating

      The Defelsko N45S split 45 ° micro probe has the smallest measurement tip and excellent thin film Measurement accuracy. This probe is suitable for measurement of small parts, hard-to-reach areas or near edges. PRBN45S-D split 45 ° micro probe 625μm range.

      Brand
      SKU: NB015164
      United States Defelsko
      Stock
      Loading…
      Price
      $ 1017.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • Defelsko PRBN45S-D Thickness Gauge probeOverview

        • Specifications
        • Comments
        • FAQs
        PRBN45S-D
        Thickness Gauge probe


        Full range of probe details

        The Defelsko PosiTector 6000 Coating Thickness Gauge has a detachable built-in probe diagram Detachable built-in probe

        F,N,FN,FT


        Suitable for one-handed operation




        Detachable built-in probeProbe modelF、N、FNFT
        Defelsko PosiTector 6000 Coating Thickness Gauge Detachable Internal Probe Dimensional Drawingrange0~60 mils0~250mils
        0~1500μm0~6mm/0~6000μm
        precision

        + (0.05 mils + 1%)  0~2 mils

        + (0.1 mils  +  1%)  > 2 mils

        + (0.5 mils + 1%)  0~100 mils

        + (0.5 mil + 3%) > 100 mils

        + (1 um + 1%)  0~50 um

        + (2 um + 1%)  > 50 um

        + (0.01 mm + 1%) 0~2.5 mm

        + (0.01 mm + 3%) > 2.5 mm

        Accuracy is calculated by adding a fixed value to the percentage of readings


        Defelsko PosiTector 6000 Series Coating Thickness Gauge Split Conventional Transducer

        Split conventional probes

        FS,NS,FNS,NAS,FTS


        These constant-pressure, stainless steel probes are hermetically sealed and completely waterproof – ideal for underwater measurements.



        RegularProbe modelFS、NS、FNSNASFTS
        Dimension drawing of the Defelsko PosiTector 6000 Series Coating Thickness Gauge Split Conventional Transducerrange0~60 mils0~25 mils0~250 mils
        0~1500 um0~625 um0~6 mm/0~6000 μm
        precision

        + (0.05 mils + 1%)  0~2 mils

        + (0.1 mils  +  1%)  > 2 mils

        + (0.02 mils + 1%)  0~4 mils

        + (0.1 mils + 3%)  > 4 mils

        + (0.5 mils + 1%)  0~100 mils

        + (0.5 mil + 3%) > 100 mils

        + (1 um + 1%)  0~50 um

         + (2 um + 1%)  > 50 um

        + (.5 um + 1%)  0~100 um

         + (2 um + 3%)  > 100 um 

         + (0.01 mm + 1%) 0~2.5 mm

        + (0.01 mm + 3%) > 2.5 mm

        Accuracy is calculated by adding a fixed value to the percentage of readings


        Defelsko PosiTector 6000 Series Coating Thickness Gauge FXS Xtreme Probe

        FXS Xtreme™


        Uniquely designed for applications with rough surfaces. The measuring surface of the FXS Xtreme™ probe is a zirconia toughened alumina wear surface, which is ideal for measuring rough steel surfaces.

        Increases the measurement speed to 50 readings per minute, making it suitable for fast measurement of large, rough surfaces. The scan mode increases the rate of measurement to more than 100 readings per minute. (Only PosiTector Premium models have a scan mode)

        Compatible with PosiTector mainframes with serial numbers greater than 700,000 and the new Positector SmartLink.



        FXS Xtreme™
        Defelsko PosiTector 6000 Series Coating Thickness Gauge FXS Xtreme Probe Dimensional Drawingrange0~1500 um
        0~60 mils
        precision

        + (0.05 mils + 1%)  0~2 mils

        + (0.1 mils  +  1%)  > 2 mils

        + (1 um + 1%)  0~50 um

        + (2 um + 1%)  > 50 um

        Accuracy is calculated by adding a fixed value to the percentage of readings


        Defelsko PosiTector 6000 Series Coating Thickness Gauge Split 90℃onventional Transducer

        Split 90° conventional probe

        FRS,NRS,FNRS

        Right-angle probes are suitable for measuring low headroom areas.

        These constant-pressure, stainless steel probes are hermetically sealed and completely waterproof – ideal for underwater measurements



        90° conventional typeProbe modelFRS、NRS、FNRS
        Defelsko PosiTector 6000 Series Coating Thickness Gauge Split 90℃onventional Transducer Dimension Drawingrange0~60 mils
        0~1500 um
        precision

        + (0.05 mils + 1%)  0~2 mils

        + (0.1 mils  +  1%)  > 2 mils

        + (1 um + 1%)  0~50 um

        + (2 um + 1%)  > 50 um

        Accuracy is calculated by adding a fixed value to the percentage of readings


        Defelsko PosiTector 6000 Series Coating Thickness Gauge FNDS Probes

        FNDS

        The PosiTector 6000 FNDS probe simultaneously measures the thickness of paint and zinc layers in a composite coating system in a single readout.

        Composite coating systems use a combination of two corrosion protection systems – typically painted or powder coated on galvanized steel (thermal, electrical, or zinc-sprayed metal). resultantCorrosion protection due toanySeparate protection system.

        In composite mode, the positector 6000 FNDS is usedmagnetic induction(ferrous) and eddy current (non-ferrous) principles that simultaneously calculate and display individual coating and zinc layer thicknesses. The magnetic induction principle is used to measure the total thickness of the lacquer/zinc layer on a ferrous substrate, while the eddy current Thickness Gauge principle is used to measure the thickness of the paint layer on a non-ferrous zinc layer. The zinc layer thickness is calculated by subtracting the thickness of the paint layer from the total lacquer/zinc layer thickness. The schematic diagram is as follows,

        The PosiTector 6000 FNDS probe measures the decomposition intent of lacquer-zinc composite coatings

        When not available, the gauge is like a traditional ferrous/non-ferrous dual-function gauge (similar topositector 6000 FNS probe). It is suitable for measuring the thickness of non-magnetic coatings on steel and non-conductive coatings on non-ferrous metal substrates.

        Positicctor Advanced (serial number 730000+) and color LCD are compatible with the Positicctor standard gage. A simple Thickness Gauge update is required.

        FNDS
        Defelsko PosiTector 6000 Series Coating Thickness Gauge FNDS Probe Dimensional Drawingrange0~60 mils/0~1500 um
        Composite coatingMinimum zinc layer thickness0.5 mil (13 um)
        Paint layer accuracyMils

        + (0.05 mils + 1%)  0~2 mils

        + (0.1 mils  +  1%)  > 2 mils

        μm

        + (1 um + 1%)  0~50 um

         + (2 um + 1%)  > 50 um

        Zinc layer accuracyMils

        + (0.1 mils + 1%)  0.5~2 mils

        + (0.2 mils  +  1%)  > 2 mils

        μm

        + (2 um + 1%)  13~50 um

         + (4 um + 1%)  > 50 um

        Accuracy is calculated by adding a fixed value to the percentage of readings


        Diagram of the Defelsko PosiTector 6000 Coating Thickness Gauge Split 0° ProbeSplit 0° probe

        F0S,N0S

        With a minimal measuring tip and very good thin-film measurement accuracy, this probe is suitable for measuring small parts, hard-to-reach areas or near edges.

        The straight F0S and N0S miniature probes have a quick-release adapter that allows them to be targeted at a constant pressure on small, flat or curved parts. This adapter is designed on a spring, if you don't need a sleeve, simply unplug it from the probe.

        0° miniature probeProbe modelF0SN0S
        Dimension drawing of the Defelsko PosiTector 6000 Coating Thickness Gauge Split 0° Proberange0~45 mils0~25 mils
        0~1150 um0~625 um
        precision

        + (0.02 mils + 1%)  0~4 mils

        + (0.1 mils + 3%)  > 4 mils

        + (0.5 um + 1%)  0~100 um

        + (2 um + 3%)  > 100 um 

        Accuracy is calculated by adding a fixed value to the percentage of readings


        Diagram of the Defelsko PosiTector 6000 Coating Thickness Gauge Split 0° Probe

        Split 45° miniature probe

        F45S,N45S

        With a minimal measuring tip and very good thin-film measurement accuracy, this probe is suitable for measuring small parts, hard-to-reach areas or near edges.



        45° miniature probeProbe modelF45SN45S
        Dimension drawing of the Defelsko PosiTector 6000 Coating Thickness Gauge Split 45° Proberange0~45 mils0~25 mils
        0~1150 um0~625 um
        precision

        + (0.02 mils + 1%)  0~4 mils

        + (0.1 mils + 3%)  > 4 mils

        + (0.5 um + 1%)  0~100 um

        + (2 um + 3%)  > 100 um 

        Accuracy is calculated by adding a fixed value to the percentage of readings


        Diagram of the Defelsko PosiTector 6000 Coating Thickness Gauge Split 90° Micro Probe

        Split 90° miniature probe

        F90S,N90S

        Right-angle probes are suitable for measuring low headroom areas.

        With a minimal measuring tip and very good thin-film measurement accuracy, this probe is suitable for measuring small parts, hard-to-reach areas or near edges.



        90° miniature probeProbe modelF90SN90S
        Dimension drawing of the Defelsko PosiTector 6000 Coating Thickness Gauge Split 90° Miniature Proberange0~45 mils0~25 mils
        0~1150 um0~625 um
        precision

        + (0.02 mils + 1%)  0~4 mils

        + (0.1 mils + 3%)  > 4 mils

        + (0.5 um + 1%)  0~100 um

        + (2 um + 3%)  > 100 um 

        Accuracy is calculated by adding a fixed value to the percentage of readings


        Defelsko PosiTector 6000 Coating Thickness Gauge Large Range Probe

        Wide-range probes

        FT,FTS,FNTS,FKS,NKS


        Suitable for thick coatings such as epoxy resin, rubber, cement, intumescent fire retardant coatings, etc.



        Large-scale typeProbe modelFT,FTS,FNTSFKS,NKS
        Defelsko PosiTector 6000 Coating Thickness Gauge FT Probe, USADefelsko PosiTector 6000 Coating Thickness Gauge FTS Probe Size DrawingDefelsko PosiTector 6000 Coating Thickness Gauge FNTS, FKS, NKS Transducer Size Drawingrange0~250 mils0~500 mils

        0~6 mm/0~6000 μm0~13 mm/0~500 mils
        precision

        + (0.5 mils + 1%)  0~100 mils

        + (0.5 mil + 3%) > 100 mils

        + (1 mils + 3%) 

        + (0.02 mm + 3%) 

        + (0.01 mm + 1%) 0~2.5 mm

        + (0.01 mm + 3%) > 2.5 mm

        FTFTSFNTS,FKS,NKSAccuracy is calculated by adding a fixed value to the percentage of readings


        Defelsko PosiTector 6000 Coating Thickness Gauge FHXS Xtreme ProbeFHXS Xtreme

        Measure non-conductive coatings on steel substrates


        The FHXs Xtreme probe comes with alumina, abrasion-resistant contact surfaces and braided cables for use on hot or rough surfaces. Hot surface temperatures can be as high as 250°C (500°F).

        Compatible with PosiTector mainframes with serial numbers greater than 700,000 and the new Positector SmartLink.



        FHXS Xtreme
        Defelsko PosiTector 6000 Coating Thickness Gauge FHXS Xtreme probe size drawingrange0~400 mils
        0~10000 um
        precision

        + (0.1 mils + 3%) 

        + (2 um + 3%)

        Accuracy is calculated by adding a fixed value to the percentage of readings


        Defelsko PosiTector 6000 Coating Thickness Gauge FLS probe diagram

        FLS

        Suitable for measuring intumescent varnish and other thick protective coatings on steel.

        ● Measure thickness up to 38mm (1.5 inches)

        ● Braided stainless steel cable - torsion-resistant, abrasion-resistant, shear-resistant

        ● Includes hard case and 19 mm (750 mil) spacer

        Compatible with PosiTector mainframes with serial numbers greater than 700,000 and the new Positector SmartLink.



        FLS
        Defelsko PosiTector 6000 Coating Thickness Gauge FLS Probe Size Drawingrange0~38 mm
        0~1.5inch
        precision+ (0.01 in. + 3%)
        + (0.2 mm + 3%)
        Minimum surface area3.25 x 3.25 inches (83 x 83 mm)
        Minimum substrate thickness0.1inch(2.5 mm)
        Accuracy is calculated by adding a fixed value to the percentage of readings


        Defelsko PosiTector 6000 Coating Thickness Gauge FNGS Probe Size Drawing

        FNGS

        Suitable for measuring very thick coatings on all metals. It is particularly suitable for measuring hull coatings and thick intumescent coatings.

        ● Measure thicknesses up to 63.5 mm (2.5 inches)

        ● Measure the thickness of non-conductive coatings on magnetic and non-magnetic metal substrates.

        ● Braided stainless steel cable - torsion-resistant, abrasion-resistant, shear-resistant

        ● Long-lasting, low-wear probe contact for easy scanning of large areas.

        ● Includes a handle for easy one-handed operation

        ● Includes a set of traceable coating thickness standards

        ● Instruction cards are included

        Compatible with PosiTector mainframes with serial numbers greater than 700,000 and the new Positector SmartLink.

        FLS

        Defelsko PosiTector 6000 Coating Thickness Gauge FNGS Probe Size Drawing

        Probe weight: 0.8kg

        range0~63.5 mm
        0~2.5inch
        precision+ (0.01" + 3%)
        + (0.2 mm + 3%)
        Minimum surface area10 x 10 inches (254x254 mm)
        Minimum substrate thickness0.2inch(2.5 mm)
        Accuracy is calculated by adding a fixed value to the percentage of readings

        Probe Purchase Chart

        F – Ironsubstrate(Steel & Cast Iron)

        N - NonIronmetalsubstrate(Aluminum, copper, titanium, etc.)

        FN – All metal substrates – automatic identification of substrates

        Probe modelsubstrateProbe typeMeasuring range
        FIronMovable built-in0~60 mils (0~1500 um)
        FSIronConventional cables0~60 mils (0~1500 um)
        FXS Xtreme™Ironroutinecable0~60 mils (0~1500 um)
        FRSIron90° conventional cable0~60 mils (0~1500 um)
        F0SIron0° miniature probe0~45 mils (0~1150 um)
        F45SIron45° miniature probe0~45 mils (0~1150 um)
        F90SIron90° miniature probe0~45 mils (0~1150 um)
        FTIronMovable built-in0~250 mils (0~6 mm)
        FTSIronA wide range of cables0~250 mils (0~6 mm)
        FKSIronA wide range of cables0~500 mils (0~13 mm)
        FHXS Xtreme™IronA wide range of cables0~400 mils (0~10000 um)
        FLSIronA wide range of cables0~1.5 inches (0~38 mm)
        NnotIronMovable built-in0~60 mils (0~1500 um)
        NSnotIronConventional cables0~60 mils (0~1500 um)
        NRSnotIron90° conventional cable0~60 mils (0~1500 um)
        NASnotIronConventional cables0~25 mils (0~625 um)
        N0SnotIron0° miniature probe0~25 mils (0~625 um)
        N45SnotIron45° miniature probe0~25 mils (0~625 um)
        N90SnotIron90° miniature probe0~25 mils (0~625 um)
        NKSnotIronA wide range of cables0~500 mils (0~13 mm)
        FNIron/notIronMovable built-in0~60 mils (0~1500 um)
        FNSIron/notIronConventional cables0~60 mils (0~1500 um)
        FNRSIron/notIron90° conventional cable0~60 mils (0~1500 um)
        FNDS (duplex)Iron/notIronConventional cables0~60 mils (0~1500 um)
        FNTSIron/notIronA wide range of cables0~250 mils (0~6 mm)
        FNGSIron/notIronA wide range of cables0~2.5 inches (0~63.5 mm)


        VS

        Defelsko PRBN45S-D Thickness Gauge probeSpecifications

        LIST VALUE
        Measurement principle Eddy Current
        Measurement range 0~625μm
        margin of error ±1%
        Resolution 0.1μm
        probe 6000 N45S Cabled Probe
        Probe size Φ5mm
        Calibrated Certificate Yes.
        compatible model PosiTector

        Defelsko PRBN45S-D Thickness Gauge probe Packing list

        Probe x1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        For small products such as screws and nuts, 1-2 MM with a small probe contact surface is required. Is this suitable?
        [A]
        Too small to measure
        Defelsko
        Defelsko N45S split 45 ° micro probe, thin coating
        Service