JENCO 3631 (set) pH oxidation reduction control/transmitter
JENCO 3631 pH oxidation reduction control/transmitter Measurement range is -0.00~14.00pH, Measurement accuracy is +/- 0.01pH +/- 1 word and resolution is 0.01pH, JENCO3631 is a laboratory pH oxidation reduction control/transmitter with automatic temperature compensation function.
JENCO-
Online pH meter QIWEI PH-110 0~14pH
$ 148.00 -
LEICI 218 reference electrode silver/silver chloride single salt bridge
$ 88.00 -
LEICI E-201-P planar pH composite electrode
$ 102.00 -
LEICI PHB-5 Portable pH Meter PH/mV/Temperature 0.01 Class
$ 419.00 -
FANGZHOU FZ-221 PH electrode low ion and tack sample testing
$ 285.00
Features
Standard 1/8 DIN waterproof body design correction value power-off memory function.
pH or ORP values can be measured.
4~20mA reversible, with isolated current output, the output range can be set by the user.
2 sets of pH relay control, control point/hysteresis width can be set by the user.
It has the function of automatic temperature compensation.

| Optional | ||
| pH electrode | IP-600-1 | In the field of wastewater treatment with high turbidity, it can be used in a long-term environment of 80 degrees |
| IP-600-10 | In the field of ordinary carved water treatment, there is no temperature compensation | |
| IP-600-9PT | In the field of ordinary carved water treatment, automatic temperature compensation | |
| IP-600-3C | Pure water, ultrapure water measurement | |
| ORP electrodes | IR-500-8 | In the field of general wastewater, -2000mV~2000mV |
| IR-500-9 | In the field of general wastewater, -1000mV~1000mV | |
| Mounting bracket | 009A | 1 meter pool mounting bracket |
| Sealed box | 011-200-00 | Dial-mounted |
| 012-200-00 | Wall-mounted | |
JENCO 3631 (set) pH oxidation control/transmitterSpecifications
| LIST | VALUE |
|---|---|
| PH range | -0.00~14.00pH |
| PH Measurement Accuracy | ±0.01pH |
| Resolution | 0.01pH |
| Power Supply | 110或230VAC,50/60Hz |
| Dimensions | 1/4DIN standard body, 96 * 46 * 119mm |
| Measurement range mV | -1999~1999mV |
| mV resolution | 1mV |
| Measurement Accuracy of mV | ±0.5%F.S |
| Current output range | 4~ 20M isolated current output |
| Insulation Voltage/maximum load | 500VDC/550Ω |
| Relay Control Output/Maximum Load | System ON/OFF control/2.5A/230VAC |
| opening size | 92*46mm |
| Shop Accessories | pH electrode, ORP electrode, mounting bracket, sealing box |
JENCO 3631 (set) pH oxidation control/transmitter Packing list
Host X1, IP-600-9TH (5 meters) X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Ren's JENCO 3671 pH/ORP Controller Instruction Manual
- Ren's JENCO 3621 Microcomputer pH/ORP Controller Instruction Manual
- Ren's JENCO 3331 Microcomputer Conductivity Detector/resistivity transmitter manual
- Ren's JENCO MODEL 3321 Microcomputer Conductivity Detector/resistivity controller Instructions for use
- Ren's JENCOMODEL 3250M Microcomputer Processing Conductivity Detector/TDS/salinity/temperature Portable measuring instrument Operation manual
- JENCO MODEL 3173 Microcomputer Processing Conductivity Detector Benchtop measuring instrument Instruction manual
- Ren's JENCO 3107 Microcomputer Desktop Conductivity Detector Instruction Manual
- Ren's JENCO ORP 628N Microcomputer Type ORP & Temperature Test Pen Instructions for Use
- Ren's JENCO3010M laboratory conductivity meter instruction manual
- Ren's JENCO692 pH Transmitter Instructions for Use
- ActiveJJF 919-2023
- ActiveISO 19396-2-2017
- ActiveISO 19396-1-2017
- ActiveGB/T 21894-2008
- ActiveGB/T 20623-2006
- ActiveGB/T 6368-2008
- ActiveGB/T 1545-2008
- ActiveGB 8325-1987
- ActiveGB/T 13531.1-2008
- ActiveGB/T 11165-2005
- ActiveJB/T 6858-1993
- ActiveHG/T 4164-2010
- ActiveQB/T 4103-2010
- ActiveGB/T 2750-2011
- ActiveGB/T 27756-2011
- ActiveGB/T 7790-2008


3631 (set)