JENCO 3010M portable conductivity conductivity range 0.00uS~ 400.0mS
0~400mS/0.01µS, salinity display 0~80ppt, TDS (with 2 ring electrodes)
JENCO-
DDKSIC DJS-0.01VT Low Range Conductivity Detector electrode for pure water, ultrapure water distillation water, etc
$ 188.00 -
LEICI DDSJ-319L Conductivity Meter Pure water/linear/non-compensation 3 kinds of temperature compensation methods
$ 1380.00 -
HANNA HI98308 Ultra low range conductivity EC Tester
$ 203.00 -
FANGZHOU FZ-704W Conductivity Detector electrode (platinum black) 200µs/cm-200mS/cm
$ 133.00 -
LEICI DDS-11A Digital Display Conductivity Meter
$ 253.00
Features
The 3010M measures conductivity, salinity, and temperature.
Automatic temperature compensation.
Microcomputer design, correction value power-off memory function.
50 sets of measurement data memory function.
Low battery warning function,
It has an automatic shutdown function.
IP65 waterproof body design.
CMC, ROHS, CE certification.

| Optional | |
| 109A | K=0.1 glass two-wire conductivity electrode (pure water, ultrapure water measurement) |
| 107A | K=10.0 glass (outer tube plastic) two-wire conductivity electrode (high conductivity medium water measurement) |
JENCO 3010M Portable conductivitySpecifications
| LIST | VALUE |
|---|---|
| Measurement range | 0.00μS/cm~400.0mS/cm |
| Measurement error | ±0.5% F.S. |
| Resolution | 0.01uS~0.1mS |
| Temperature compensation range | -10.0~90.0℃ |
| Data storage | 50 sets |
| Power Supply | 9V battery |
| Operating temperature | 0~50℃ |
| Operating humidity | ≤90℅RH |
| Dimensions | 186*70*37mm |
| Weight | 260G (without battery) |
| Salinity range | 0.0~70.0ppt |
| Salinity resolution | 0.1ppt |
| Measurement Accuracy of salinity | ±0.2%F.S. |
| Measurement range | -10.0~90.0℃ |
| Display resolution | 0.1℃ |
| Temperature Accuracy | +/- 0.2 ℃ or 0.4% F.S. whichever is greater |
| Electrode constant specification | K=0.1/1.0/10.0 |
| reference temperature | 15.0~25.0 ℃ adjustable, the default value is 25.0 ℃ |
| temperature coefficient | 0.00~4.00% adjustable, the default value is 1.91% |
| TDS conversion factor | 0.30~1.00 (default 0.65) |
| calibration data store | Yes. |
| Sound feedback | All keys |
| shutdown mode | Automatic shutdown |
| Shop Accessories | K = 0.1 Glass two-wire Conductivity Detector electrode (pure water, ultrapure water measurement), K = 10.0 Glass (outer tube plastic) two-wire Conductivity Detector electrode (high conductivity medium water measurement) |
JENCO 3010M Portable conductivity Packing list
Host X1, 106A electrode X1, suitcase X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Ren's JENCO3010M laboratory conductivity meter instruction manual
- Ren's JENCO 3671 pH/ORP Controller Instruction Manual
- Ren's JENCO 3621 Microcomputer pH/ORP Controller Instruction Manual
- Ren's JENCO 3331 Microcomputer Conductivity Detector/resistivity transmitter manual
- Ren's JENCO MODEL 3321 Microcomputer Conductivity Detector/resistivity controller Instructions for use
- Ren's JENCOMODEL 3250M Microcomputer Processing Conductivity Detector/TDS/salinity/temperature Portable measuring instrument Operation manual
- JENCO MODEL 3173 Microcomputer Processing Conductivity Detector Benchtop measuring instrument Instruction manual
- Ren's JENCO 3107 Microcomputer Desktop Conductivity Detector Instruction Manual
- Ren's JENCO ORP 628N Microcomputer Type ORP & Temperature Test Pen Instructions for Use
- Ren's JENCO3010M laboratory conductivity meter instruction manual
- ActiveJJG 2059-2014
- ActiveJB/T 9366-2017
- ActiveSL 78-1994
- ActiveGB/T 12582-1990
- ActiveGB/T 13580.3-1992
- ActiveGB/T 18932.15-2003
- ActiveGB/T 11007-2008
- ActiveGB/T 23977-2009
- ActiveGB/T 20245.3-2013
- ActiveGB/T 41079.2-2022
- ActiveGB/T 6908-2018
- ActiveGB/T 7977-2007
- ActiveGB/T 32697-2016
- ActiveGB/T 33328-2016
- ActiveISO 21318-2007
- ActiveISO 9944-1990
- ActiveISO 8502-9-2020
- ActiveGB/T 27503-2011
- ActiveGB/T 27502-2011
- ActiveJB/T 9366-1999


3010M