JINGKELIAN QMB minimum film forming temperature (MFFT) Tester, stainless steel profiled temperature layer
Operating temperature range of layer plate -7~ 70 ℃, temperature measurement point 13 points, layer interval 20mm, test Coating tank 6, inspection table shows 16 points, of which 1~ 13 points for the working layer temperature, 14 points for the instrument Environmental temperature, 15, 16 points for the chilled down water inlet and outlet temperature, standard GB9267-88.
JingKeLian-
TQC VF9600 MFFT10 minimum film forming temperature (MFFT) Tester -10~80 ℃
$ 39193.00 -
JINGKELIAN QMB-II minimum film forming temperature (MFFT) Tester GB9267 standard
$ 2779.00 -
TQC VF9700 MFFT20 minimum film forming temperature (MFFT) Tester -30~ + 250 ℃
$ 60310.00 -
JINGKELIAN QMB minimum film forming temperature (MFFT) Tester, stainless steel profiled temperature layer
$ 2835.00 -
PUSHEN MFFT minimum film forming temperature (MFFT) Tester
$ 3568.00
Overview of QMB Minimum Film Formation Temperature Meter
JinKeLian QMB minimum film-forming temperature measuring instrument is designed according to the national standard GB9267-88. It adopts platinum resistance imported from Germany as the temperature sensor, and adopts the LU-906M intelligent temperature regulator combined with fuzzy control theory and PID control to ensure the display The error is less than 0.5%±1 word. The remarkable feature of the QMB Minimum Film Forming Temperature Meter is the use of a stainless steel special-shaped temperature gradient plate with a temperature adjustment range of -7°C to 70°C.
Advantages of QMB Minimum Film Forming Temperature Meter
1. Desktop energy saving
2. The temperature sensor adopts platinum resistance imported from Germany, and the LU-906M intelligent temperature regulator combined with fuzzy control theory and PID control, and the display error is less than 0.5%±1 character.
3. The temperature gradient plate is a stainless steel special-shaped temperature gradient plate. The main components are the temperature control system (intelligent temperature regulator, high-precision temperature sensor, switching power supply, semiconductor refrigeration device), inspection system, drying device and corresponding electrical control circuit.
4. Professional semiconductor refrigeration and high-power regulated switching power supply reduce the noise of the refrigeration system.
5. The measuring instrument is equipped with a water cut-off
6. The cooling water temperature is displayed (at the 15th and 16th points of the inspection table), and the water flow is minimized (manually) according to different setting conditions.
7. There are obvious subdivision scales on the front and back of the workbench, which is convenient for accurate judgment of MFT .
Display of QMB Minimum Film Forming Temperature Meter

JingKeLian QMB Minimum film forming temperature (MFFT) TesterSpecifications
| LIST | VALUE |
|---|---|
| Layer operation temperature range | -7~70℃ |
| Temperature measurement point | 13 point |
| Layer spacing | 20mm |
| Test Coating Tank | 6 strips, length 240mm, width 22mm (national standard 20~25mm), depth 0.25mm (national standard 0.20~ 0.30mm) |
| Inspection form display | 16 point, of which 1 to 13 point is the working layer temperature, 14 point is the instrument environment temperature, 15 and 16 point are the inlet and outlet temperature of the chilled down water |
| standard | GB9267-88 |
JingKeLian QMB Minimum film forming temperature (MFFT) Tester Packing list
Film formation temperature tester x1, plexiglass cover x1, drying agent box x2, power cord x1, catheter x2, Spreader doctor blade x1, fuse x8, manual x1, certificate x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveHG/T 4448-2012
- ActiveGB/T 20623-2006
- ActiveGB/T 9267-2008
- AbolishGB/T 11175-2002
- ISO 2115-1996
- AbolishGB/T 9267-1988


QMB
QMB-II