HYLOLOGY HYL-105 Angle of repose Tester
The funnel outlet diameter of the HYLOLOGY HYL-105 angle of repose Tester is 5mm, the protractor is 10cm, the distance between the bottom of the outflow port and the disk surface of the HYL-105 angle of repose Tester is 80mm +/- 2mm, and the diameter of the material plate is 0019 80mm.
hylology-
XIONGFA XF-4324 Powder Angle of repose meter Injection limited bottom surface method Angle of repose Tester
$ 517.00 -
HYLOLOGY HYL-1001 Powder comprehensive characteristic Tester, multi-functional powder physical characteristic Tester
$ 5325.00 -
XIONGFA XF-11986 Powder Carr Angle of Repose Tester, Surfactant Powder Particle flowability Tester
$ 534.00
Introduction
The dust angle of repose (or angle of repose) refers to the acute angle between the dust accumulation slope and the bottom horizontal plane.
ããHYL-105 injection limited bottom method angle of repose Tester is based on the national standard GB/T 16913.5-1997 (this standard adopts ISO 4324:1997 Powdered and granular surfactants - powders and granules - determination of angle of repose ) stipulated design and production. The applicable measurement object of this device is dust. The dust angle of repose is determined by injecting a limited bottom surface method. The main technical difference from ISO 4324:1997 is that the height of dust accumulated on the limited bottom surface is not measured and a protractor is used to directly measure the dust angle of repose.

principle
Dust sufficient to overflow the material pan is injected into the horizontal material pan from the funnel mouth; measure the acute angle between the dust accumulation slope and the bottom horizontal plane, which is the dust angle of repose.
Instrument structure (the entire set of equipment is made of 304 stainless steel)
(1) Funnel (outlet diameter 5mm),
ããthe funnel taper is 60º±0.5º;
(2) Protractor
ãã: Protractor 10cm;
(3) Chassis:
ããThe distance between the bottom of the outflow outlet and the plate surface is 80mm±2mm, and the diameter of the material plate is Φ80mm.
(4) Repeatability Error â¤1%.
hylology HYL-105 Angle of repose MeterSpecifications
| LIST | VALUE |
|---|---|
| principle | Sufficient overflow of dust into the tray from the hopper mouth to the horizontal tray; measurement of dust accumulation slope and the bottom of the horizontal plane between the acute angle, that is, the dust resting angle. |
| Funnel outlet diameter | 5mm |
| Funnel taper | 60º±0.5º |
| protractor | 10cm |
| chassis | The distance between the bottom of the outflow port and the plate surface is 80mm +/- 2mm, and the diameter of the material plate is φ 80mm. |
| Repeatability Error | ≤1% |
hylology HYL-105 Angle of repose Meter Packing list
machine X1, clogging rod X1, overflow funnel X1, sample table X1, sample spoon X1, brush X1, warranty card X1, manual X1, certificate X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


HYL-105



