The panel is equipped with dual SPDT high-low relays for pH/ORP controller/transmitter, which can be manually set and calibrated by potentiometer. 4-20mA current output, externally selectable pH or ORP. Big red LED display, BNC connector, antenna lead lug, axial flow square. This instrument requires a Pt-100 ATC or analog resistor for temperature. The power supply used is 115/230 AC.

Features
Isolated 4-20mA output
Double closed relay
Large LCD display
Automatic temperature compensation
115VAC/230VAC operation
1/4 DIN housing
Low-strength solid-state design
Adjustable control of the output current span of the front panel
The front panel selects and switches between acid and alkali liquids
The front panel high-low relay format selection switch
JENCO 3676 pH oxidation controllerSpecifications
| LIST | VALUE |
|---|---|
| PH range | -0.00~14.00pH |
| pH resolution | 0.01pH |
| pH Accuracy | +/- 0.01pH +/- 1 word |
| Measurement range mV | -1999~1999mV |
| mV resolution | 1mV |
| ORP Accuracy | ±0.5%F.S. |
| Current output range | 4~ 20M isolated current output |
| Insulation Voltage/maximum load | System ON/OFF control/2.5A/230VAC |
| Power Supply | 110或230VAC,50/60Hz |
| opening size | 92x92mm |
| Dimensions | 1/4DIN standard body, 96x96x119mm |
| Shop Accessories | pH electrode, ORP electrode, mounting bracket, sealing box |
| Display | LED display |
JENCO 3676 pH oxidation controller Packing list
host X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Ren's JENCO 3671 pH/ORP Controller Instruction Manual
- Ren's JENCO 3621 Microcomputer pH/ORP Controller Instruction Manual
- Ren's JENCO 3331 Microcomputer Conductivity Detector/resistivity transmitter manual
- Ren's JENCO MODEL 3321 Microcomputer Conductivity Detector/resistivity controller Instructions for use
- Ren's JENCOMODEL 3250M Microcomputer Processing Conductivity Detector/TDS/salinity/temperature Portable measuring instrument Operation manual
- JENCO MODEL 3173 Microcomputer Processing Conductivity Detector Benchtop measuring instrument Instruction manual
- Ren's JENCO 3107 Microcomputer Desktop Conductivity Detector Instruction Manual
- Ren's JENCO ORP 628N Microcomputer Type ORP & Temperature Test Pen Instructions for Use
- Ren's JENCO3010M laboratory conductivity meter instruction manual
- Ren's JENCO692 pH Transmitter Instructions for Use


3676