KORNO MOT500-TVOC-Y Online TVOC Detector 0-500ppm
$ 1751.00 -
KORNO GT1000-VOC-Y Organic solvent volatile gas, alcohol Detector
$ 727.00 -
KORNO GT903-TVOC-Y TVOC Detector, range 0-2ppm
$ 2463.00 -
KORNO MOT500-VOC-Y Fixed organic solvent volatile gas, alcohol Detector
$ 562.00 -
KORNO MOT500-TVOC-Y air mass /TVOC Detector 0-10PPM
$ 525.00
Equipped with "typhoon" technology, it is designed for extreme weather and condensation environments!
Falco is a new generation of stationary VOC Detectors that utilize patented photoionization (PID) technology to continuously detect a wide range of volatile organic compounds (VOCs).
This fixed VOC Detector features revolutionary "typhoon" technology that protects the PID sensor from condensation and moisture, thus providing greater reliability in extreme weather conditions. Moreover, the PID sensor uses patented fence electrode technology to protect the instrument from contamination by virtually eliminating the effects of moisture vapor in the air.
This Falco VOC Detector delivers professional performance, reliability, accuracy, and results you can count on to ensure that workers and plants receive the utmost protection on an ongoing basis. The equipment is designed to be resistant to moisture and contamination, which minimizes drift and downtime, saving you time and money.
Falco provides the highest level of safety to avoid reading errors with other PID technologies in its class. The coloured LED status display is visible from up to 20 metres away in sunlight, ensuring that you receive hazard warnings clearly.
Falco external intrinsically safe sensors allow for quick and easy maintenance without the need for a thermal work permit. The Falco has dual certifications to accept maintenance and calibration in hazardous environments without a power outage.
The Falco Stationary VOC Detector has an intuitive user interface that makes it easy to operate. It is equipped with five magnetic switches with LED confirmation lights, a high-contrast OLED screen, and a graphical interface, ensuring that installation and maintenance can be made quick and easy.
All models are uniformly equipped with RS485 (Modbus®), 4-20 mA, and relay outputs. The relay outputs can be configured for high-low alarms, fault conditions, or test cycle synchronization.
The Falco stationary VOC Detector is extremely flexible and is available in both suction and diffusion models with a total of four measuring ranges. The diffuse version is extremely low maintenance and requires no pump maintenance.

Features
Good performance
A VOC Detector designed for extreme weather
'Typhoon technology prevents condensation from forming inside the PID
Professional sensor performance minimizes drift and downtime
Extremely high level of security
Prevents reading errors from other PID technologies in its class
The color status display can be seen from up to 20 meters away in sunlight
Equipped with a long-life bulb that lasts for two years
Vandal-proof certification
Extreme flexibility
There are two models: pump suction type and diffusion type
For hard-to-access locations, pump-and-suction instruments are the perfect choice
The diffusion type reduces maintenance costs
Four detection ranges are available
Different response factors can be selected according to different VOCs
Ion Science FALCO VOC DetectorSpecifications
| LIST | VALUE |
|---|---|
| Detection principle | Photoionization with 10.6 eV bulbs |
| Detection range and Sensitivity | 10.0 ppm* 0.001 ppm 50.0 ppm* 0.01 ppm 1000 ppm* 0.1 ppm 3000 ppm* 1 ppm |
| Detection time (T90) | < 30 seconds (diffusion type) |
| user interface | Display: OLED high contrast ratio White text on black background: 128 (W) x 64 (H) pixels Screen size: 35 mm (W) x 17.5 mm (H) Five magnetic switches with LED confirmation lights (i.e. up, down, left, right and confirmation). A magnetic actuator is provided. |
| status indicator | Bright and Visible Status Indicator: Red, Yellow and Green Colors |
| certification | II 2G Ex d ib IIC T4 Gb ISO9001:2008 |
| Environment specification | No pump: -40 ℃ to 60 ℃ (-40 ° F to 140 ° F) With pump: -40 ℃ to 60 ℃ (-40 ° F to 140 ° F) 0-100% Relative Humidity and condensed moisture |
| mechanical interface | Two cable access points with 3/4 NPT threads (left and right) Two 3/4 NPT in M20 stainless steel (supplied) |
| Dimension | No pump: 200 (height) * 190 (width) * 125 (depth) mm With pump: 290 (height) * 190 (width) * 125 (depth) mm |
| Installation point | 2 MB |
| Input Power | Operating Voltage: 12 to 40 Vdc, Maximum Power: 7 Watts |
| output | 4 to 20 mA (active and passive) RS485 supports Modbus ® protocol, relays and 2 SPST switches (60 Vdc 2A) - configurable |
Ion Science FALCO VOC Detector Packing list