JINGHUA 722 visible spectrophotometer high performance grating, low stray light, wide sample chamber
Adopt high-performance 1200L/mm grating and C-T monochromator structure, stray light ≤ 0.1% T, Stability +/- 0.001A/H, wide sample chamber can be adapted to 100mm sample holder to meet various needs.
jinghua-
JINGHUA 756CRT UV-Visible Spectrophotometer Light spectrum
$ 4423.00 -
JINGHUA 7600S Dual beam of light UV-Visible Spectrophotometer Wavelength Accuracy +/- 0.3nm
$ 5045.00 -
JINGHUA 756 UV-Visible Spectrophotometer 2nm Light spectrum Bandwidth 190-1100nm Wavelength range
$ 1781.00 -
YueFeng 754 Ultraviolet-visible Spectrophotometer 195~ 1000nm Bandwidth 4.0nm
$ 786.00 -
YUEFENG FP6426 Flame photometer K/Ba
$ 1439.00

Features
High-performance 1200L/mm optical lens, CT-type monochromator structure, equipped with imported tungsten lamp and high-sensitivity photoelectric converter, ensure that the instrument has high resolution, high luminosity linearity, and low stray light. Improved test accuracy and stability.
The large sample room allows you to choose sample racks up to 100mm, which can meet the needs of different industries.
With T, A, C, F and other functions.
jinghua 722 Visible spectrophotoMeterSpecifications
| LIST | VALUE |
|---|---|
| Light spectrum bandwidth | 4nm |
| Wavelength range | 330~1000nm |
| Wavelength Accuracy | ±2nm |
| Wavelength Repeatability | 1nm |
| stray light | ≤0.1%T |
| Stability | ±0.001A/H |
| Interface | RS-232 interface |
| printout | optional |
| analysis software | optional |
| Transmittance Accuracy | ≤0.5%T |
| Transmittance Repeatability | 0.2%T |
| Transmittance range | 0~200%T |
| Absorption range | -0.301~3A |
| Display range of concentration | 0~99999 |
jinghua 722 Visible spectrophotoMeter Packing list
host X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- How to install Jinghua Spectrophotometer correctly?
- The specific operation method of Jinghua Spectrophotometer
- Application of Spectrophotometer in Spectral Reflectance
- Structure principle and optical system principle of Spectrophotometer
- How does a Spectrophotometer measure the color of beer?
- ActiveGB/Z 38062-2019
- IncomingGB/T 27594-2025
- ActiveJC/T 1040-2020
- ActiveJY/T 0570-2020
- ActiveGB/T 7744-2023
- ActiveGB/T 15503-1995
- AbolishGB/T 10656-2008
- ActiveGB/T 34323-2017
- ActiveGB/T 11220.1-1989
- AbolishHJ/T 201-2005
- ActiveGB/T 6369-2008
- ActiveGB/T 27594-2011
- AbolishGB/T 1628.2-2000
- ActiveGB/T 1721-2008
- ActiveGB/T 26810-2011
- AbolishGB/T 11175-2002
- ISO 6271-2-2004
- ISO 4630-2-2004
- ISO 3856-5-1984
- ISO 3856-2-1984


722