MODERNER QXD-15 single-channe Fineness gauge stainless steel material 0~15μm range
Single-channe, range 0~15μm, scale unit μm, stainless steel, applicable to GB/T 1724, GB/T 13217.3, ISO 1524, ASTM D1210, Graduation 0.75μm.
Moderner-
TQC VF2117 Fineness gauge drawdown blade for all models of TQC Grindometer
$ 498.00 -
QXP0-50S double-channel Fineness gauge YONGLIDA QXP Fineness gauge
$ 215.00 -
TQC VF2118 double-channel fineness grindometer 0-250 µm with calibrated certificate
$ 1247.00 -
CHINA QXD-15 double-channel Grindometer Zirconia Ceramic Material 0~15μm
$ 459.00 -
TQCsheen VF2143 single-channe Grindometer Range 0~1000μm
$ 2177.00
QXD-15 single groove Fineness of Grind Gauge is a small stainless steel single groove Fineness of Grind Gauge for MODERNER. QXD-15 single-slot Fineness of Grind Gauge is suitable for particle fineness detection in coatings, pigments, printing inks and other industries. It is a manual fineness detection.
Application
The Applications of QXD single-slot Fineness of Grind Gauge include paint, plastic, pigment, printing ink, paper, ceramics, medicine, food, etc.
real shot



operation method
1. Before using the QXD-15 single-slot Fineness of Grind Gauge, soak the plate and bottom with a suitable solvent, and dry it with cotton yarn.
2. Fully stir the sample that meets the product standard viscosity index with an ink-adjusting knife.
3. Drop a few drops of sample solution into the deepest part of the groove of the QXD single-groove Fineness of Grind Gauge .
4. Hold the scraper with the thumb, index finger and middle finger of both hands, and place it horizontally on the upper end of the stainless steel Grindometer, so that the scraper is perpendicular to the surface of the Grindometer, and pull the scraper from the deep part of the groove to the shallow part at an appropriate speed. The paint swatch fills the grooves without leaving excess paint on the panel.
5. After scraping, immediately pinch the QXD single-groove Fineness of Grind Gauge horizontally (within 5 seconds) and tilt it so that the line of sight is 15-20 degrees from the groove plane, and observe the particle uniformity in the groove with light. and the scale value at the exposed place, the reading value is the fineness of the measured object.
Maintenance
(1) Clean it immediately after use and apply vaseline to prevent the fineness gauge from rusting.
(2) Do not scratch the surface of the QXD-15 single-slot Fineness of Grind Gauge and the scraper.
(3) When measuring the fineness, the clear oil that meets the product standard should be adjusted first, and then measured with the QXD single-slot Fineness of Grind Gauge .
(4) Regularly (one year) check the knife edge and the straightness of the fineness gauge. If unevenness or wear of the fineness gauge is found, it needs to be calibrated by the national metrology and verification agency before it can be used.
Specification list

Series
| Specification | Range | Division value | Groove size | unit |
| small single slot | 0-15 | 0.75 | 12.7*140 | μm |
| 0-25 | 1.25 | Hegman/μm | ||
| 0-50 | 2.5 | |||
| 0-100 | 5 | |||
| 0-150 | 5 | μm | ||
| small double slot | 0-25 | 2.5 | Hegman/μm | |
| 0-50 | 2.5 | |||
| 0-100 | 5 | |||
| 0-150 | 5 | μm | ||
| wide slot | 0-25 | 1.25 | 25.4*127 | Hegman/μm |
| 0-50 | 2.5 | |||
| 0-100 | 5 | |||
| large wide groove | 0-25 | 2.5 | 50.8*127 | |
| 0-50 | 5 | |||
| 0-100 | 5 | |||
| Big double slot | 0-25 | 2.5 | 25.4*165 | Hegman/μm/NPIRI |
| 0-50 | 5 | |||
| 0-100 | 5 | |||
| Special double slot | 0-50 | 2 | μm | |
| 0-250 | 10 | μm |
Moderner QXD-15 (single-channe) Single-channe Fineness gaugeSpecifications
| LIST | VALUE |
|---|---|
| Scraper type | Single-channe |
| Number of grooves | 1 |
| range | 0 ~ 15µm |
| Scale unit | mm |
| Scraper material | stainless steel |
| Scraper size | 170*50*12mm |
| Groove size | 12.7*140mm |
| Scraper material | stainless steel |
| Scraper size | 70mm |
| Applicable standard | GB/T 1724、GB/T 13217.3、ISO 1524、ASTM D1210 |
| Graduation | 0.75µm |
Moderner QXD-15 (single-channe) Single-channe Fineness gauge Packing list
Scraper x1, scraper x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveSJ/T 10454-2020
- ActiveHG/T 5173-2017
- ActiveGB/T 42541-2023
- ActiveGB/T 21894-2008
- ActiveHG/T 5776-2020
- ActiveHG/T 5175-2017
- ActiveQB/T 5477-2020
- ActiveASTM D1210-05-2022
- ActiveJB/T 9385-2017
- ActiveASTM D1316-2020
- ActiveJJG 905-2010
- ActiveASTM D333-2021
- ActiveISO 1524-2020
- AbolishGB/T 13217.3-2008
- ReplacedQB/T 2025-1994
- ReplacedASTM D1210-1996
- ReplacedISO 1524-2000
- ActiveGB/T 17459-1998
- ActiveGB/T 5211.17-1988
- AbolishJJG 905-1996


QXD-15 (single-channe)