      Home> VOC Detector> KORNO> KORNO MOT500-VOC-Y Organic solvent volatile gas, alcohol Detector

      KORNO MOT500-VOC-Y Fixed organic solvent volatile gas, alcohol Detector

      VOC, range 0~100ppm, resolution 0.1ppm, Response time ≤ 20s (T90), Linearity ≤ +/- 1%, accuracy ≤ +/- 3% (depending on the specific Sensors)

      Brand
      SKU: NB016089
      China KORNO
      Stock
      Loading…
      Price
      $ 562.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • KORNO MOT500-VOC-Y Organic solvent volatile gas, alcohol DetectorOverview

        • Specifications
        • Comments
        • FAQs
        MOT500-VOC-Y
        Organic solvent volatile gas, alcohol Detector
        • KORNO MOT500-VOC-Y Fixed organic solvent volatile gas, alcohol Detector
        • KORNO MOT500-VOC-Y Fixed organic solvent volatile gas, alcohol Detector Figure 1
        • KORNO MOT500-VOC-Y Fixed organic solvent volatile gas, alcohol Detector Figure 2
        VOC, range 0~100ppm, resolution 0.1ppm, Response time ≤ 20s (T90), Linearity ≤ +/- 1%, accuracy ≤ +/- 3% (depending on the specific Sensors)

        Introduction

        MOT500 online volatile organic Gas Detector is suitable for continuous online detection of volatile organic gas concentration in various environments. The instrument adopts imported PID photoion sensor and microcontroller technology, which has the advantages of stable signal, high precision and good repeatability. , Explosion-proof wiring is suitable for various dangerous places.

        Features

        KORNO MOT500-VOC-Y organic solvent volatile gas and alcohol Detector 1

        KORNO MOT500-VOC-Y organic solvent volatile gas and alcohol Detector 2

        KORNO MOT500-VOC-Y organic solvent volatile gas and alcohol Detector 3

        VS

        KORNO MOT500-VOC-Y Organic solvent volatile gas, alcohol DetectorSpecifications

        LIST VALUE
        Detect gas VOC
        range 0~100ppm
        resolution 0.1ppm
        Response time ≤20s(T90)
        Linearity ≤±1%
        Accuracy ≤ +/- 3% (depending on the Sensors)
        Zero drift ≤ +/- 1% (F. S/year)
        recovery time ≤ 20 seconds
        Repeatability ≤±1%
        gas expansion Supports 1-6 Sensors (optional)
        Explosion-proof sign CNEx16.0547
        Protection level IP65
        production license Guangdong 00001052 (CMC metrology authentication)
        Humidity measurement Optional accessories, temperature detection range: -25~ 60 ℃, Humidity detection range: 0~95% RH
        Sampling method Diffusion, flow, pump suction optional
        Installation method Wall-mounted, pipeline type (thread size: M40X1.5mm), circulation type
        signal output ① 4-20mA signal: standard 16-bit Accuracy 4-20mA output chip, transmission distance 1Km, ② RS485 signal: using standard MODBUS RTU protocol, transmission distance 2Km, ③ Voltage signal: 0-5V, 0-10V output, can be set by yourself
        signal output ④ Optional 4-20mA + Hart output, ⑤ Switching signal: standard 2 sets of relays, optional third set of relays, passive touchpoint, Capacity 220VAC 3A/24VDC 3A
        transmission method ① Cable transmission: 3-core, 4-core cable, long-distance transmission (1-2 kilometers), ② TCP/IP transmission: support TCP/IP protocol, use optical fiber and network cable, long-distance real-time transmission through intranet and extranet (optional)
        transmission method ③ GPRS transmission: built-in GPRS module, real-time remote data transmission, no distance limit (optional), ④ wireless transmission: support 433Mhz, radio transmission mode, transmission distance 2-10Km, depending on different Power (optional)
        receiving device User computer, control alarm, PLC, DCS, mobile phone, tablet computer, etc. are optional
        Alarm mode On-site sound and light alarm, external alarm, remote Controller alarm, computer data collection software alarm, mobile app notification, SMS alarm optional
        Alarm settings ① Standard configuration two-level alarm, optional three-level alarm ② Gas Sensors can set two alarm modes of conventional high and low alarm and interval control, which can control the concentration range of gas ③ Temperature sensor can set the control range ④ Humidity Sensors can set the control range
        Shell material Die casting aluminum + sand blasting oxidation/fluorocarbon paint, explosion-proof and anti-corrosion
        optional range 0-100、500、1000、5000ppm
        Operating temperature -30~50℃
        Relative Humidity ≤ 95% RH, non-condensing
        Working pressure 0 ~ 100Kpa
        Power Supply 24VDC(12~30VDC)
        Dimension 200*149*79mm
        Net Weight 1.5Kg
        execution standard GB3836.1-2010 "Explosive environments - Part 1: Equipment - General requirements", GB3836.2-2010 "Explosive environments - Part 2: Equipment protected by flameproof enclosures" d "

        KORNO MOT500-VOC-Y Organic solvent volatile gas, alcohol Detector Packing list

        host X1, calibration cover X1, manual X1, certificate X1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        I want to do a test about the GB/T23984 standard. Is this organic solvent volatile gas alcohol detector okay?
        [A]
        Sure
        KORNO
        KORNO MOT500-VOC-Y Fixed organic solvent volatile gas, alcohol Detector
        Service
        Focus on online sales of Lab Testing Instruments