KORNO MOT500-CO2-Y (infrared 1%) online carbon dioxide Detector 0-500ppm
CO2, range 0~500ppm, resolution 1ppm, Response time T90 ≤ 20s, Linearity ≤ +/- 1%, detection accuracy ≤ +/- 1%, explosion-proof mark CNEx16.0547, Protection level IP65
KORNO-
BOSEAN BH-90-NO Portable Gas Alarm Instrument 0~250ppm
$ 226.00 -
HONEYEAGLE HNAG1000-HCL Fixed Hydrogen Chloride Detector 0-50PPM
Login -
GUOYUGRA GY/VGD-200-NOX-G (0-20ppm) nitrogen oxide Detector
$ 270.00 -
Empaer APEG-D-EX Volkswagen Series Fixed Gas Detector
$ 234.00 -
HONEYEAGLE HNAG1000-ETO Fixed ethylene oxide Detector 0-100PPM
Login
Introduction
MOT500 online infrared carbon dioxide Detector is suitable for carbon dioxide concentration detection in various environments. It adopts imported NDIR infrared absorption gas sensor and microcontroller technology, with fast response speed, high measurement accuracy, good stability and repeatability, and the whole machine The performance is at the domestic (CN) professional level.
Features



KORNO MOT500-CO2-Y (IR 1%) Carbon dioxide Detector (infrared 1%)Specifications
| LIST | VALUE |
|---|---|
| Detect gas | CO2 |
| Range | 0~500ppm |
| resolution | 1ppm |
| Response time | T90≤20s |
| Linearity | ≤±1% |
| detection Accuracy | ≤±1% |
| Zero drift | ≤ +/- 1% (F. S/year) |
| recovery time | ≤20s |
| Repeatability | ≤±1% |
| expansion gas | Supports 1-6 Sensors (optional) |
| Explosion-proof sign | CNEx16.0547 |
| Protection level | IP65 |
| production license | Guangdong 00001052 (CMC metrology authentication) |
| Humidity | Optional accessories, temperature detection range: -25~ 60 ℃, Humidity detection range: 0~95% RH |
| Sampling method | Diffusion, flow, pump suction optional |
| Installation method | Wall-mounted, pipeline, circulation |
| Operating temperature | -30~50℃ |
| Environmental humidity | 0~95% RH non-condensing |
| Operating Pressure | 0~100Kpa |
| Power Supply | 24VDC(12~30VDC) |
| Dimension | 200*149*79mm |
| Weight | 1.5Kg |
| execution standard | GB3836.1-2010、GB3836.2-2010 |
| signal output | ① 4-20mA signal ② RS485 signal ③ Voltage signal |
| signal output | ④ Optional 4-20mA + Hart output ⑤ switching signal |
| receiving device | User computer, control alarm, PLC, DCS, mobile phone, tablet computer, etc. are optional |
| Alarm mode | On-site sound and light alarm, external alarm, remote Controller alarm, computer data collection software alarm, mobile app notification, SMS alarm optional |
| Shell material | Die casting aluminum + sand blasting oxidation/fluorocarbon paint, explosion-proof and anti-corrosion |
| optional range | 0~500, 2000, 5000, 10000, 50000ppm, 20%, 50%, 100% Vol (Accuracy ≤ +/- 1% F. S) |
KORNO MOT500-CO2-Y (IR 1%) Carbon dioxide Detector (infrared 1%) Packing list
host X1, calibration cover X1, manual X1, certificate X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJF 1523-2015
- ActiveJB/T 11937-2014
- ActiveGB/T 3394-2023
- ActiveGB/T 20936.3-2017
- ActiveGB 3836.4-2010
- AbolishGB 3836.1-2010
- ActiveGB 15322.1-2019


MOT500-CO2-Y (IR 1%)