KORNO MOT500-O2-Y oxygen Detector, range 0-30% Vol
O2, range 0~30% vol, resolution 0.01% vol, Response time T90 ≤ 20s, Linearity ≤ +/- 1%, detection accuracy ≤ +/- 3%, explosion-proof mark CNEx16.0547, Protection level IP65
KORNO-
SMART SENSOR smart sensor AS8800L Combustible Gas Detector reaction time ≤ 1 second
$ 88.00 -
GUOYUGRA GY/VGD-200-CHCL3-G (0-50ppm) Trichloromethane Detector
$ 518.00 -
GUOYUGRA GY/VGD-200-C3H8-G (0-5000ppm) Propane Detector (Infrared)
$ 817.00 -
BH-60-HCN (with display + alarm) Fixed HCN Gas Detector 0~10ppm
$ 257.00 -
KORNO GT-903-H2S-Y Pump suction hydrogen sulfide Detector 0-50ppm
$ 270.00
Introduction
MOT500 online hydrogen sulfide Detector is suitable for hydrogen sulfide gas concentration detection in various environments. It adopts imported electrochemical gas sensor and microcontroller technology, with fast response speed, high measurement accuracy, good stability and repeatability, and the whole machine The performance is at the domestic (CN) professional level.
Features



KORNO MOT500-O2-Y Oxygen DetectorSpecifications
| LIST | VALUE |
|---|---|
| Detect gas | Oxygen O2 |
| Range | 0~30%vol |
| resolution | 0.01%vol |
| Response time | T90≤20s |
| Linearity | ≤±1% |
| detection Accuracy | ≤±3% |
| Zero drift | ≤ +/- 1% (F. S/year) |
| recovery time | ≤20s |
| Repeatability | ≤±1% |
| expansion gas | Supports 1-6 Sensors (optional) |
| Explosion-proof sign | CNEx16.0547 |
| Protection level | IP65 |
| production license | Guangdong 00001052 (CMC metrology authentication) |
| Humidity | Optional accessories, temperature detection range: -25~ 60 ℃, Humidity detection range: 0~95% RH |
| Sampling method | Diffusion, flow, pump suction optional |
| Installation method | Wall-mounted, pipeline, circulation |
| Operating temperature | -30~50℃ |
| Environmental humidity | 0~95% RH non-condensing |
| Operating Pressure | 0~100Kpa |
| Power Supply | 200*149*79mm(L×W×H) |
| Dimension | 180*85*55mm |
| Weight | 1.5Kg |
| execution standard | GB3836.1-2010、GB3836.2-2010 |
| signal output | ① 4-20mA signal ② RS485 signal ③ Voltage signal |
| signal output | ④ Optional 4-20mA + Hart output ⑤ switching signal |
| receiving device | User computer, control alarm, PLC, DCS, mobile phone, tablet computer, etc. are optional |
| Alarm mode | On-site sound and light alarm, external alarm, remote Controller alarm, computer data collection software alarm, mobile app notification, SMS alarm optional |
| Shell material | Die casting aluminum + sand blasting oxidation/fluorocarbon paint, explosion-proof and anti-corrosion |
| optional range | 0~1000、5000、10000、30000ppm、5%、30%、100%.Vol |
| Sensors Life | 2-3 years |
KORNO MOT500-O2-Y Oxygen Detector Packing list
host X1, calibration cover X1, manual X1, certificate X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveHJ 872-2017
- ActiveSN/T 5162-2019
- ActiveJB/T 11621-2013
- ActiveGB/T 20936.3-2017
- ActiveGB/T 20936.2-2017
- ActiveGB 3836.4-2010
- AbolishGB 3836.1-2010
- ActiveGB 15322.1-2019


MOT500-O2-Y