KORNO MOT500-NO-Y In-line nitric oxide Detector, pump suction type 50ppm
Pump type, NO, range 0~50ppm, resolution 0.01ppm, Response time T90 ≤ 20s, Linearity ≤ +/- 1%, detection accuracy ≤ +/- 3%
KORNO-
GUOYUGRA GY/VGD-200-CS2-G (0-50ppm) carbon disulfide Detector
$ 568.00 -
GUOYUGRA GY/VGD-200-H2-G (0-100ppm) Hydrogen Detector
$ 257.00 -
HUIRUIPU HRP-T1000-NH3 Ammonia Gas Detector (no display with light)
$ 215.00 -
HONEYEAGLE HNAG1000-H2 Fixed Hydrogen Detector 0-50000PPM
$ 607.00 -
HONEYEAGLE HNAG1000-HBR Fixed Hydrogen Bromide Detector 0-400PPM
Login
Introduction
MOT500 online nitric oxide Detector is suitable for continuous online detection of nitric oxide concentration in various industrial environments and special environments. The instrument uses imported electrochemical sensors and microcontroller technology, with stable signals, high precision, and good repeatability. Advantages, the explosion-proof wiring method is suitable for various dangerous places.
Features



KORNO MOT500-NO-Y Nitric oxide DetectorSpecifications
| LIST | VALUE |
|---|---|
| Detect gas | Nitric oxide NO |
| Range | 0~50ppm |
| resolution | 0.01ppm |
| Response time | T90≤20s |
| Linearity | ≤±1% |
| detection Accuracy | ≤±3% |
| Zero drift | ≤ +/- 1% (F. S/year) |
| recovery time | ≤20s |
| Repeatability | ≤±1% |
| expansion gas | Supports 1-6 Sensors (optional) |
| Explosion-proof sign | CNEx16.0547 |
| Protection level | IP65 |
| production license | Guangdong 00001052 (CMC metrology authentication) |
| Humidity | Optional accessories, temperature detection range: -25~ 60 ℃, Humidity detection range: 0~95% RH |
| Sampling method | Diffusion, flow, pump suction optional |
| Installation method | Wall-mounted, pipeline, circulation |
| Operating temperature | -30~50℃ |
| Environmental humidity | 0~95% RH non-condensing |
| Operating Pressure | 0~100Kpa |
| Power Supply | 24VDC(12~30VDC) |
| Dimension | 200*149*79mm |
| Weight | 1.5Kg |
| execution standard | GB3836.1-2010、GB3836.2-2010 |
| signal output | ① 4-20mA signal ② RS485 signal ③ Voltage signal |
| signal output | ④ Optional 4-20mA + Hart output ⑤ switching signal |
| receiving device | User computer, control alarm, PLC, DCS, mobile phone, tablet computer, etc. are optional |
| Alarm mode | On-site sound and light alarm, external alarm, remote Controller alarm, computer data collection software alarm, mobile app notification, SMS alarm optional |
| Shell material | Die casting aluminum + sand blasting oxidation/fluorocarbon paint, explosion-proof and anti-corrosion |
| optional range | 0~50、100、250、500、1000、2000ppm |
KORNO MOT500-NO-Y Nitric oxide Detector Packing list
host X1, calibration cover X1, manual X1, certificate X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveHJ 872-2017
- ActiveJB/T 11621-2013
- ActiveGB/T 20936.3-2017
- ActiveGB 3836.4-2010
- AbolishGB 3836.1-2010
- ActiveGB 15322.1-2019


MOT500-NO-Y