KORNO MOT500-NOX-Y Online Nitrogen Oxide Detector 0-100ppm
NOX, range 0~100ppm, resolution 0.01ppm, Response time T90 ≤ 20s, Linearity ≤ +/- 1%, detection accuracy ≤ +/- 3%, explosion-proof mark CNEx16.0547, Protection level IP65
KORNO-
HUIRUIPU HRP-T1000-CO Carbon Monoxide Gas Detector (with display and no light)
$ 156.00 -
Empaer AATL-O2 (sound and light alarm) Pathfinder series fixed oxygen Detector
$ 338.00 -
HUIRUIPU HRP-T1000-O2 Oxygen Gas Detector (no display with lamp)
$ 184.00 -
HONEYEAGLE HNAG1000-SO2 Online sulfur dioxide Detector 0-2000PPM
$ 591.00 -
Empaer AASD-SO2 Lightning Series Handheld Sulfur Dioxide Detector
$ 590.00
Introduction
MOT500 online nitrogen oxide Detector is suitable for continuous online detection of nitrogen oxide concentration in various industrial environments, flue gas tail gas and special environments. The instrument adopts imported electrochemical sensor and microcontroller technology, with stable signal, high precision, Good repeatability and other advantages, the explosion-proof wiring method is suitable for various dangerous places.
Features



KORNO MOT500-NOX-Y Nitrogen oxide DetectorSpecifications
| LIST | VALUE |
|---|---|
| Detect gas | NOX |
| Range | 0~100ppm |
| resolution | 0.01ppm |
| Response time | T90≤20s |
| Linearity | ≤±1% |
| detection Accuracy | ≤±3% |
| Zero drift | ≤ +/- 1% (F. S/year) |
| recovery time | ≤20s |
| Repeatability | ≤±1% |
| expansion gas | Supports 1-6 Sensors (optional) |
| Explosion-proof sign | CNEx16.0547 |
| Protection level | IP65 |
| production license | Guangdong 00001052 (CMC metrology authentication) |
| Humidity | Optional accessories, temperature detection range: -25~ 60 ℃, Humidity detection range: 0~95% RH |
| Sampling method | Diffusion, flow, pump suction optional |
| Installation method | Wall-mounted, pipeline, circulation |
| Operating temperature | -30~50℃ |
| Environmental humidity | 0~95% RH non-condensing |
| Operating Pressure | 0~100Kpa |
| Power Supply | 24VDC(12~30VDC) |
| Dimension | 200*149*79mm |
| Weight | 1.5Kg |
| execution standard | GB3836.1-2010、GB3836.2-2010 |
| signal output | ① 4-20mA signal ② RS485 signal ③ Voltage signal |
| signal output | ④ Optional 4-20mA + Hart output ⑤ switching signal |
| receiving device | User computer, control alarm, PLC, DCS, mobile phone, tablet computer, etc. are optional |
| Alarm mode | On-site sound and light alarm, external alarm, remote Controller alarm, computer data collection software alarm, mobile app notification, SMS alarm optional |
| Shell material | Die casting aluminum + sand blasting oxidation/fluorocarbon paint, explosion-proof and anti-corrosion |
| optional range | 0~100、1000、2000、5000ppm |
KORNO MOT500-NOX-Y Nitrogen oxide Detector Packing list
host X1, calibration cover X1, manual X1, certificate X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveHJ 872-2017
- ActiveJB/T 11621-2013
- ActiveGB/T 20936.3-2017
- ActiveGB 3836.4-2010
- AbolishGB 3836.1-2010
- ActiveGB 15322.1-2019


MOT500-NOX-Y