KORNO MOT500-HCL-Y Online Hydrogen Chloride Detector 0-10ppm
HCL, range 0~10ppm, resolution 0.01ppm, Response time T90 ≤ 20s, Linearity ≤ +/- 1%, detection accuracy ≤ +/- 3%, explosion-proof mark CNEx16.0547, Protection level IP65
KORNO-
Empaer AATL-SO2 (4G) Pathfinder Series Stationary Sulfur Dioxide Detector
$ 722.00 -
KORNO GT-903-Y4 (CO, H2S, O2, EX) standard four-in-one Gas Detector
$ 452.00 -
GUOYUGRA GY/VGD-200-C2H6O-G (0-5% Vol) Ethanol Detector (Infrared)
$ 941.00 -
GUOYUGRA GY/VGD-200-C2H2-G (0-10ppm) acetylene Detector
$ 481.00 -
KORNO MOT500-CO2-Y (infrared 1%) online carbon dioxide Detector 0-500ppm
$ 1019.00
Introduction
MOT500 online hydrogen chloride Detector is suitable for continuous online detection of hydrogen chloride concentration in various industrial environments and special environments. The instrument adopts imported electrochemical sensors and microcontroller technology, which has the advantages of stable signal, high precision and good repeatability. Explosion-proof wiring The method is applicable to various dangerous places.
Features



KORNO MOT500-HCL-Y Hydrogen chloride DetectorSpecifications
| LIST | VALUE |
|---|---|
| Detect gas | Hydrogen chloride HCL |
| Range | 0~10ppm |
| resolution | 0.01ppm |
| Response time | T90≤20s |
| Linearity | ≤±1% |
| detection Accuracy | ≤±3% |
| Zero drift | ≤ +/- 1% (F. S/year) |
| recovery time | ≤20s |
| Repeatability | ≤±1% |
| expansion gas | Supports 1-6 Sensors (optional) |
| Explosion-proof sign | CNEx16.0547 |
| Protection level | IP65 |
| production license | Guangdong 00001052 (CMC metrology authentication) |
| Humidity | Optional accessories, temperature detection range: -25~ 60 ℃, Humidity detection range: 0~95% RH |
| Sampling method | Diffusion, flow, pump suction optional |
| Installation method | Wall-mounted, pipeline, circulation |
| Operating temperature | -30~50℃ |
| Environmental humidity | 0~95% RH non-condensing |
| Operating Pressure | 0~100Kpa |
| Power Supply | 24VDC(12~30VDC) |
| Dimension | 200*149*79mm |
| Weight | 1.5Kg |
| execution standard | GB3836.1-2010、GB3836.2-2010 |
| signal output | ① 4-20mA signal ② RS485 signal ③ Voltage signal |
| signal output | ④ Optional 4-20mA + Hart output ⑤ switching signal |
| receiving device | User computer, control alarm, PLC, DCS, mobile phone, tablet computer, etc. are optional |
| Alarm mode | On-site sound and light alarm, external alarm, remote Controller alarm, computer data collection software alarm, mobile app notification, SMS alarm optional |
| Shell material | Die casting aluminum + sand blasting oxidation/fluorocarbon paint, explosion-proof and anti-corrosion |
| optional range | 0~10、20、100、200ppm |
KORNO MOT500-HCL-Y Hydrogen chloride Detector Packing list
host X1, calibration cover X1, manual X1, certificate X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveHJ 872-2017
- ActiveJB/T 11621-2013
- ActiveGB/T 20936.3-2017
- ActiveGB 3836.4-2010
- AbolishGB 3836.1-2010
- ActiveGB 15322.1-2019


MOT500-HCL-Y






