BH-60-CH2O Fixed CH2O Gas Detector 0~10ppm
BOSEAN BH-60-CH2O fixed CH2O Gas Detector is used in metallurgy, petroleum, chemical industry, municipal and other industries to detect formaldehyde concentration values. The BH-60-CH2O measuring range is 0~10ppm. The industrial-grade Sensors and explosion-proof structure design make the BH-60 -CH2OCH2O Gas Detector has good safety and test accuracy.
Bosean-
HUIRUIPU HRP-T1000-NH3 Ammonia Gas Detector (with display and no light)
$ 215.00 -
BH-60-H2S Fixed Gas Detector 0~100ppm
$ 170.00 -
KORNO MOT500-NH3-Y Online Ammonia Gas Detector 0-50ppm
$ 507.00 -
Empaer AATL-CH4 (Sound and Light Alarm) Pathfinder Series Fixed Methane Detector
$ 290.00 -
GUOYUGRA GY/VGD-200-HCN-G (0-10ppm) hydrogen cyanide Detector
$ 270.00
Introduction
BH-60 fixed Gas Detector is a new type of Gas Detector developed and produced based on the company's many years of experience in gas detection. It is used to detect the concentration of flammable gases or other toxic and harmful gases in the air. When the concentration reaches or exceeds the preset alarm value The controller will send out an audible and visual alarm to remind you to take safety measures in time to prevent explosion and poisoning accidents, thereby ensuring the safety of life and property.
This product has the advantages of stable signal, high precision, quick response, long life, short polarization time, etc. It adopts industrial-grade sensor, and the instrument shell adopts explosion-proof and explosion-proof structure design. The 4-20mA standard signal or directly enters the DOS system, which can be widely used. In metallurgy, petroleum, chemical industry, municipal and other industries, it is at the professional level of similar products in CHINA.
The shell adopts a die-cast aluminum shell with a flameproof structure design. The groove design of the upper cover can lock the shell. The front of the sensor is designed as a downward structure to ensure good contact between the sensor and the gas. The cable inlet adopts an explosion-proof waterproof connector.






Gas parameter table
| Measured gas | Measuring range | Optional range | resolution | alarm point |
| Combustible gas EX | 0-100%lel | 0-100%vol (infrared) | 1%lel/1%vol | Low: 20 High: 50 |
| Oxygen O2 | 0-30%vol | 0-30%vol | 0.1%vol | Low: 19.5% High: 23.5%vol |
| Hydrogen sulfide H2S | 0-100ppm | 0-50/200/1000ppm | 1ppm | Low: 10 High: 20 ppm |
| carbon monoxide CO | 0-1000ppm | 0-500/2000/5000ppm | 1ppm | Low: 50 High: 150 ppm |
| carbon dioxide CO2 | 0-5000ppm | 0-1%/5%/10%vol (infrared) | 1ppm/0.1%vol | Low: 1000 High: 2000 ppm |
| NO | 0-250ppm | 0-500/1000ppm | 1ppm | Low: 50 High: 150 ppm |
| Nitrogen dioxide NO2 | 0-20ppm | 0-50/1000ppm | 0.1ppm | Low: 5 High: 10 ppm |
| Sulfur dioxide SO2 | 0-20ppm | 0-50/1000ppm | 0.1/1ppm | Low: 5 High: 10 ppm |
| Chlorine CL2 | 0-20ppm | 0-100/1000ppm | 0.1ppm | Low: 5 High: 10 ppm |
| Hydrogen H2 | 0-1000ppm | 0-500/2000/5000ppm | 1ppm | Low: 50 High: 150 ppm |
| Ammonia NH3 | 0-100ppm | 0-50/500/1000ppm | 0.1/1ppm | Low: 20 High: 50 ppm |
| Phosphine PH3 | 0-20ppm | 0-20/1000ppm | 0.1ppm | Low: 5 High: 10 ppm |
| Hydrogen chloride HCL | 0-20ppm | 0-20/500/1000ppm | 0.1ppm | Low: 5 High: 10 ppm |
| Chlorine dioxide CLO2 | 0-50ppm | 0-10/100ppm | 0.1ppm | Low: 5 High: 10 ppm |
| Hydrogen cyanide HCN | 0-50ppm | 0-100ppm | 0.1/0.01ppm | Low: 10 High: 20 ppm |
| Ethylene oxide C2H4O | 0-100ppm | 0-100ppm | 1/0.1ppm | Low: 20 High: 50 ppm |
| ozone | 0-10ppm | 0-20/100ppm | 0.1ppm | Low: 2 High: 5 ppm |
| Formaldehyde CH2O | 0-20ppm | 0-50/100ppm | 1/0.1ppm | Low: 5 High: 10 ppm |
| Hydrogen fluoride HF | 0-100ppm | 0-1/10/50/100ppm | 0.01/0.1ppm | Low: 2 High: 5 ppm |
| Xylene/Toluene | 0-20ppm | 0-1/10/50/100ppm | 0.01/0.1ppm | Low: 5 High: 10 ppm |
Bosean BH-60-CH2O Stationary Gas DetectorSpecifications
| LIST | VALUE |
|---|---|
| Range | 0~10ppm |
| resolution | 1ppm |
| Alarm point | 5ppm |
| Power Supply | DC 24V +/- 15% |
| error of indication | ±3%FS |
| System power | Maximum power consumption 3W |
| Ambient Operating Temperature | -10~40℃ |
| Dimensions | 193*140*93mm |
| Explosion-proof sign | CNEx16.0449 |
| Explosion-proof sign | Exd ⅡC T6 Gb |
| response time | <30s |
| signal output | 3-Wire 4~ 20mA or 4-wire RS485 |
| Installation method | wall mounted |
| Shell material | die casting aluminum |
| Ambient Operating Humidity | 0~95% RH non-condensing |
Bosean BH-60-CH2O Stationary Gas Detector Packing list
Complete-built unit X1, Encasement box X1, Charger X1, Calibration cover X1, Manual X1, Certificate X1, Warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveHJ 872-2017
- ActiveJB/T 11621-2013
- ActiveLY/T 1981-2011
- ActiveJB/T 12934-2016
- ActiveGB/T 20936.3-2017
- AbolishGB 3836.1-2010
- ActiveGB 15322.1-2019


BH-60-CH2O
BH-60-CH2O (with display + alarm)