DINGDING DX30B-CL2 Chlorine Gas Detector 0-20.0 ppm
DINGDING DX30B-CL2 Chlorine Gas Detector is a fixed chlorine gas concentration Detector with a detection range 0-20.0 ppm with an accuracy of < +/- 5%. The DX30B-CL2 uses an Electrochemical sensor and is connected via a G1/2 male thread explosion-proof hose.
DINGDING-
GUOYUGRA GY/VGD-200-O2-G (0-5% Vol) Industrial Grade, Oxygen Detector
$ 494.00 -
GUOYUGRA GY/VGD-200-PF5-G (0-10ppm) phosphorus pentafluoride Detector
$ 879.00 -
HUIRUIPU HRP-B1000-O2 Oxygen Gas Detector 0-30% VOL/0.1% VOL
$ 153.00 -
KORNO GT-903-CO2-Y (infrared 2%) pump suction carbon dioxide Detector 0-2000ppm
$ 489.00 -
GUOYUGRA GY/VGD-200-C2H6-G (0-5000ppm) ethane Detector (infrared)
$ 817.00
Features
The fixed chlorine detection transmitter (probe) adopts a professional imported sensor, which has stable performance, sensitivity and reliability, and good toxicity. It can be divided into display or non-display, explosion-proof or non-explosion-proof, diffusion or pumping. This transmitter is characterized by maximum flexibility, excellent performance and low installation costs. It is used in various toxic gas leakage places, such as: city gas, petroleum, chemical industry, steel, special industrial plants and other fields.

peculiarity
Professional microprocessor technology, good stability, strong interference ability
Three-wire 4-20mA analog output and 1 SPDT relay output
RS485 output to save transmission cables (optional)
High-low concentration light alarm, and the alarm concentration can be adjusted
Non-explosion-proof occasions can be selected high-power sound alarm
Explosion-proof 10-30V DC power supply
The response speed is fast and the measurement accuracy is high
Sensor: Electrochemical sensor is used for low maintenance costs
Detection gas: Hydrogen in the air (H2
DINGDING DX30B-CL2 Gas DetectorSpecifications
| LIST | VALUE |
|---|---|
| Detect gas | CL2 |
| Range | 0~20.0ppm |
| detection Accuracy | <± 5%F.S |
| resolution | 0.1ppm |
| Response time | ≤30s |
| Sensors Life | 24 months |
| Sensors principle | electrochemistry |
| Power Supply | Explosion-proof 10-30V DC Power Supply |
| Sampling method | diffusion |
| Operating Mode | Long-term continuous work |
| Output signal | 3-Wire 4-20mA analog output, RS485 output (optional) |
| Alarm mode | Sound, light. |
| transmission distance | ≥ 1000 meters |
| Connectivity | G1/2 male thread explosion-proof hose |
| structural material | die casting aluminum |
| Protection level | IP65 |
| Operating temperature | -20~50℃ |
| Environmental humidity | 0~90%RH |
| Low alarm point | 5ppm |
| High alarm point | 10ppm |
DINGDING DX30B-CL2 Gas Detector Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


DX30B-CL2