DINGDING DX30A-CO Gas Detector with display + sound and light alarm 0-1000ppm
DINGDING CO Gas Detector DX30A-CO can be used to detect CO leakage sites, is a fixed CO Gas Detector, DX30A-CO CO Gas Detector Measurement range is 0-1000ppm, using diffusion Sampling method.
DINGDING-
GUOYUGRA GY/VGD-200-Ex-G (0-100% LEL) High Temperature Combustible Gas Detector
$ 369.00 -
Empaer AATL-SO2 (sound and light alarm) Pathfinder series fixed sulfur dioxide Detector
$ 633.00 -
Empaer AASD-O2 Lightning Series Handheld Oxygen Detector
$ 295.00 -
HONEYEAGLE HNAG1000-NO2 Fixed Nitrogen Dioxide Detector 0-2000PPM
$ 582.00 -
HONEYEAGLE HNAG1000-HBR Fixed Hydrogen Bromide Detector 0-100PPM
Login
Introduction
DX30B-CO Wall Mounted Carbon Monoxide Detection Alarm (Non-explosion-proof Type, On-site Concentration Display, Sound and Light Alarm) Product Description DX300-CO Carbon Monoxide Detection Alarm can be applied to detect carbon monoxide leakage places, using imported electrochemical sensors, which has the advantages of stable signal and high accuracy.

peculiarity
- Professional microprocessor technology
-0-1000ppm range specification, users can according to the actual requirements.
- Credible, stable.
-220V AC POWER SUPPLY
- On-site concentration display, sound and light alarm
-Fast response speed and high measurement accuracy
- Very good performance and low installation costs
- Low maintenance costs
-Output signal The user can according to the actual requirements.
DINGDING DX30A-CO (with display + sound and light alarm) Gas DetectorSpecifications
| LIST | VALUE |
|---|---|
| Detect gas | CO |
| Range | 0~1000ppm |
| detection Accuracy | <±3%F.S |
| resolution | 1ppm |
| Response time | ≤25s |
| Sensors Life | 24 months |
| Sensors principle | electrochemistry |
| Power Supply | 220V AC Power Supply |
| Sampling method | diffusion |
| Operating Mode | Long-term continuous work |
| Output signal | Standard three-wire 4-20mA analog signal output; two-wire output, relay output or RS485 output (optional) |
| Cable Specifications | Model RVVP3 × 1.0mm2 |
| transmission distance | ≥ 1000 meters |
| Connectivity | G1/2 male thread hose |
| Dimension | 183*143*107mm |
| Weight | ≤1.5kg |
| Operating temperature | -20~50℃ |
| Environmental humidity | 0~90%RH |
| Low alarm point | 50ppm |
| High alarm point | 100ppm |
DINGDING DX30A-CO (with display + sound and light alarm) Gas Detector Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Types of carbon monoxide Detectors and their differences
- Gas Detectors don't underestimate the importance of LEL correlation factors
- Where is a good place to place a carbon monoxide Detector?


DX30A-CO (with display + sound and light alarm)