JUNSHUN YA-D200-VOC Fixed VOC Gas Detector 0-2000PPM
JUNSHUN YA-D200-VOC Fixed VOC Gas Detector has a range of 0-2000PPM and can work continuously for a long time. YA-D200-VOC VOC Gas Detector meets GB 50493-2009 standard and adopts die-cast aluminum structure material.
Junshun-
KORNO MOT500-TVOC-Y Online TVOC Detector 0-500ppm
$ 1751.00 -
KORNO GT-903-TVOC-Y TVOC Detector, measuring range 0-10PPM
$ 507.00 -
KORNO MOT500-VOC-Y Fixed organic solvent volatile gas, alcohol Detector
$ 562.00 -
KORNO MOT500-TVOC-Y air mass /TVOC Detector 0-10PPM
$ 525.00 -
KORNO GT1000-VOC-Y Organic solvent volatile gas, alcohol Detector
$ 727.00
Product installation precautions
According to the standard: [GB 50493-2009;6.1 Installation of Detector (probe)]
1. The installation height of the combustible Gas Detector (probe) that is heavier than air should be 0.3~0.6m away from the floor (or floor). The Detector (Detector) for detecting toxic gases with a specific gravity greater than the air should be close to the leakage point, and its installation height should be 0.3~0.6m away from the floor (or floor), and the sensor part should be downward.
2. The installation height of the Detector (probe) for detecting combustible gas or toxic gas with a specific gravity less than air should be 0.5~2m higher than the release source, and the sensor part should be downward.
3. The Detector (probe) should be installed in a place without shock, vibration, strong electromagnetic field interference, and easy to maintain, and there should be no less than 0.5m of clearance and access channel between the place where the probe is installed and the surrounding pipelines or equipment.

Junshun YA-D200-VOC Stationary Toxic Gas DetectorSpecifications
| LIST | VALUE |
|---|---|
| Detect gas | VOC |
| Range | 0~2000ppm |
| Accuracy | <±3%F.S |
| minimum reading | 1ppm |
| Response time | ≤60s |
| Sensors Life | 24 months |
| Sensors principle | Optical inspection |
| Power Supply | 24V Power Supply |
| Sampling method | diffusion |
| Operating Mode | Long-term continuous work |
| Connecting cable | National standard signal line ≥ 3 * 1.0mm ² |
| Connectivity | M20 * 1.5 male thread |
| Structural Materials | die casting aluminum |
| Explosion-proof sign | Exd Ⅱ CT6 |
| Protection level | IP65 |
| Operating temperature | -40~70℃ |
| Operating humidity | 0~90%RH |
| Dimension | 180*140*75mm |
| Weight | 1.1kg |
| transmission distance | ≤1200m |
| Installation method | Fixing bracket, tube mount, wall mount |
| Output signal | 4-20mA current signal |
| Detector input | three-wire system |
Junshun YA-D200-VOC Stationary Toxic Gas Detector Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJG 1172-2007
- AbolishGB 3836.1-2010
- ActiveGB 15322.1-2019
- ActiveGB/T 23984-2009
- ActiveGB/T 23985-2009


YA-D200-VOC