Junshun YA-D200-Freon (display + sound and light) Stationary Toxic Gas Detector DATASHEET
| Brand |
Junshun |
Model |
YA-D200-Freon (display + sound and light) |
| From |
|
Name |
Stationary Toxic Gas Detector |
Specifications
| Detect gas |
Freon |
| Sensors principle |
electrochemistry |
| Sampling method |
diffusion |
| Display |
LED digital tube, OLED LCD screen |
| Alarm mode |
Sound, light. |
| Range |
0~1ppm |
| detection Accuracy |
<±3%F.S |
| resolution |
0.1ppm |
| Response time |
≤40s |
| service life |
2 years (depending on the environment) |
| Repeatability |
≤±2% |
| Power Supply |
DC24V |
| power consumption |
<2.5W |
| Operating temperature |
-40~70℃ |
| Environmental humidity |
0~95%RH |
| Explosion-proof sign |
ExdⅡCT6 |
| Protection level |
IP65 |
| Dimension |
140*190*95mm |
| Weight |
1.3Kg |
| Output signal |
Standard: 4-20mA Optional: RS485, switch amount |
| transmission distance |
1200M three-wire system, four-wire system |
| Connectivity |
Standard: M20 * 1.5 internal thread, optional adapter |
| Shell material |
die casting aluminum |
| Installation method |
Fixing bracket, tube mount, wall mount |
| Adaptation System |
Gas alarm Controller; PLC/DCS/RTU Control system; Fire engine |
| security certification |
CMC |
| execution standard |
GB15322.1-2003;GB12358-2006 GB3836.1-2010;GB3836.2-2010 JJG695-2003 |
Packing list
machine X1, manual X1, certificate X1, warranty card X1
After-sales instructions
[Note] For after-sales services outside the Chinese mainland, if the instrument requires repair, the shipping and possible associated taxes shall be borne by the sender. Generation address of the manual: http://en.nbchao.com/p/16352/Specification.html , which is only used by users who purchase commodities from the NBCHAO.