Elcometer456 magnetic Induction Thickness Gauge A456CFBS + 90 Degree Miniature Probe
Elcometer 456 magnetic Induction Thickness Gauge A456CFBS with 90 degree miniature probe, Coating thickness detection 0~500μm, Elcometer 456 magnetic Induction Thickness Gauge can be equipped with a variety of probes, using LCD LCD screen with swirl/spin function.
Elcometer-
CHINA CTG-802-1500FV cylindrical coating Thickness Gauge, split iron-based large V type, suitable for surface measurement
$ 226.00 -
List Magnetik Pocket TOP-CHECK FE Pocket platings Thickness Gauge
$ 1159.00 -
JINGKELIAN QDX paint film multi-purpose Detector
$ 335.00 -
Germany EPK FN1.6/90 Thickness Gauge probe 90 ° thickness measurement range 0~1600um
$ 2623.00 -
KAIRDA F10 Large Range Probe NDT530 Coating Thickness Gauge optional probe
$ 312.00
Elcometer456 Thickness Gauge is divided into 3 types: B (basic type), S (standard type), T (advanced type). In addition, it is also divided into integral and split Thickness Gauges.
The split Thickness Gauge provides a variety of probes (probes need to be purchased separately), making measurement more maneuverable.
This Elcometer 456 A456CFBS split magnetic Thickness Gauge is a basic split magnetic coating Thickness Gauge, equipped with T456CFM3---A probe, and the thickness measurement range is 0~1500μm.
![]() | ![]() | ![]() | ![]() |
Features
Easy to use
Large buttons are easy to operate even when wearing gloves
Multilingual menu settings
High contrast color LCD with auto-rotation function
High-low limit indicator signs
Factory calibrated and ready to use right out of the box
Readings are accurate
Measurement accuracy ±1~3%
Can be used in accordance with many national and international standards
Thermal stability measurement
Improves resolution readings for thin coatings
Accurate measurement on smooth, rough, thin and curved surfaces
Reliable measurement
High repeatability and reproducibility
2-year console warranty
Full set of traceable inspection certificates provided
Data sets are equipped with date and time stamp functions
solid
Sealed, durable and impact resistant
Dustproof and waterproof, protection level equivalent to IP64
The display is highly resistant to scratches and solvents
Instrument and probe construction are durable
Suitable for use in harsh environments
efficient
Fast reading: 70+/min, using ultrasound/scanning probe: 140+/min
Multiple calibration memory
alphabetic array identifier
User selectable calibration method
Compatible with ElcoMaster® and ElcoMaster® Mobile App
Powerful
Various probes can be used interchangeably
USB interface
Bluetooth® data output to iPhone* or Android⢠device (available in standard and advanced models)
Capable of measuring coatings up to 31mm thick on metal substrates
Complying with formal quality system certifications such as ISO 9001 requires instruments to properly control, record and calibrate data. Users require that instrument measurement data should be traceable to various national standards. A wide range of nominal and certified diaphragms are available, along with zero plates, to ensure the accuracy of these instruments.
![]() | ![]() |
|
| Large screen display, easy to read, both metric and imperial units | The screen displays up to 8 statistics, and the statistical content is user selectable. | On-screen trend graph shows the last 20 measured values |
|
| ![]() |
| Playback of individual batch readings as numbers or graphs (Advanced) | A variety of probes (need to be purchased separately) are available for a wide range of applications | 2.4" color display allows users to see data more clearly from all angles |
ElcoMaster data management software features
ElcoMaster® helps you review your data and generate professional reports quickly and easily. Built-in wizards guide you every step of the way, from connecting instruments to generating reports.
1. Use the ElcoMaster® software wizard to connect (Bluetooth or USB) to the Elcometer Thickness Gauge to download data quickly and easily.
2. ElcoMaster® can download the measurement results of all inspections from any Elcometer instrument.
3. Data can be stored into a simple file tree by project and detection type . The data is clearly displayed in the table
4. Using ElcoMaster®'s built-in report design, readings can be quickly displayed on images or drawings.
5. Readings from different Elcometer instruments can be printed on the same report - and quickly inserted into standard reports.
6. Suitable for cloud computing.
Elcometer A456CFBS+T456CFM3R90A Coating Thickness GaugeSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | Magnetic Induction |
| Measurement range | 0~500μm |
| margin of error | ±1~3%/±2.5μm |
| Resolution | 0.1μm|1μm |
| Minimum measurement surface | 4mm |
| Minimum radius of curvature | Depending on the probe selected |
| probe | Split |
| Calibrated Certificate | Yes. |
| Calibrated mode | Factory calibrated, two point calibrated, zero point calibrated, single point calibrated |
| Unit display | μm/mils |
| statistical function | Number of readings, average value, standard deviation, minimum limit, maximum limit, coefficient of variation |
| Interface | USB |
| Data storage | Last 5 Measured values |
| Power Supply | 2 AA batteries, rechargeable batteries can also be used |
| Standards | AS 2331.1.4, AS 3894.3-B, AS/NZS 1580.108.1, ASTM B 499, ASTM D 7091, ASTM E 376, ASTM G 12,BS 5599,EN 13523-1, IMO MSC.215(82), IMO MSC.244 (83) |
| Display screen | 2.4 " (6 cm) QVGA color TFT display, 320x240 pixels |
| Operating temperature | 80℃ |
| Operating temperature | -10~50℃ |
| Battery life | With 1 reading per second, it can work continuously for up to 24h |
| Protection level | IP64 |
| supporting software | ElcoMaster ® Software |
| Machine Weight | 161G (including battery) |
| Machine size | 141*73*37mm |
Elcometer A456CFBS+T456CFM3R90A Coating Thickness Gauge Packing list
Thickness gauge host * 1, thickness gauge probe * 1, calibration shim * 6, zero plate * 1, protective cover * 1, lanyard * 1, factory certificate * 2, operation manual * 1, battery * 2
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ELCOMETER 123 Surface Roughness Tester Operation Method
- Elcometer 456 A456CFNFBI1 Coating Thickness Gauge Beauty Appreciation
- Comparison of two concrete Coating Thickness Gauges
- Eletroplating Nickel Thickness Gauge Selection Case on Steel
- British elcometer Coating Thickness Gauge classification
- What is the accuracy of Elcometer Coating Thickness Gauge?
- One article takes you to know glossiness, reflectance and fog shadow
- Elcometer 506 Adhesion Tester Features
- Elcometer 456 Coating Thickness Gauge
- Elcometer 355 Coating Thickness Gauge Iron and non-iron based probe selection table
- ActiveHG/T 3240-2007
- ActiveQJ 990.3A-2011
- ReplacedNF EN ISO 2808-2007
- ActiveGB/T 42541-2023
- ActiveGB/T 13912-2020
- ActiveGB/T 7991.5-2014
- ActiveJJG 818-2018
- ActiveGB/T 1727-2021
- ActiveHG/T 20720-2020
- ActiveSY/T 0315-2013
- ActiveISO 2178-2016
- ActiveASTM B499-2021
- ActiveISO 19840-2012
- ActiveGB/T 1740-2007
- ASTM E376-2019
- ActiveISO 2808-2019
- AbolishJJG 889-1995
- ActiveGB/T 4956-2003
- ISO 6158-1984
- ISO 2361-1982