Germany Knix QNix4500P/5 paints Thickness Gauge magnetic Induction/eddy Current thickness measurement 5/3mm
The German Nix QNix4500P/5 paints Thickness Gauge has magnetic Induction and eddy Current two cladding thickness measurement modes, the measurement of paint thickness is 0~5mm and 0~3mm, QNix4500P/5 is split strip type, QNix4500 paints Thickness Gauge with ruby probe, can automatically identify the substrate.
Qnix-
List Magnetik Pocket TOP-CHECK FE Pocket platings Thickness Gauge
$ 1159.00 -
Qnix 5500 Coating Thickness Gauge
$ 790.00 -
German EPK N02 eddy current Thickness Gauge probe, thickness measurement range 0~200um
$ 1569.00 -
German PHYNIX Surfix SX-N0.5A Split Micro Probe Coating Thickness Gauge
$ 2062.00 -
Germany EPK MiniTest 735 FN1.5 dual-use Film Thickness Gauge thickness 0~1500μm/0~700μm
$ 2636.00
QNix@4500 coating Thickness Gauge is widely used in the field of coatings and automotive coatings, QNix@4500 is a magnetic induction and eddy current dual-purpose coating Thickness Gauge, this model is a standard version of the integrated probe, can not only be used to measure magnetic substrates such as steel, but also can be used to measure aluminum, copper, stainless steel and other non-magnetic metal surface coatings, oxide film, phosphate film and other coatings. These two models are simple to operate, easy to carry, and have high precision, which are loved by the majority of users.

Benefits:
1. Simple and fast measurement
2. No calibration is required
3. Automatic power on/off
4. Large range FE: 0-5000um NFE: 0-3000um
5. Dual-purpose probe, cost-effective
6. Hall sensor makes the measurement more stable
7. The sound is synchronized during measurement
8. Ruby wear-resistant head, long life
9. Backlight LED display, the reading is clearer
10、Automatic recognition of the measurement substrate
11. Split probe to meet different measurement environments
Product Applications
Type F:
Measure the thickness of non-magnetic coating layers on ferromagnetic metal substrates such as steel and iron, such as: paints, powders, various anti-corrosion coatings, plastics, rubber, synthetic materials, phosphating layers, chromium, zinc, lead, tin, cadmium, etc.;
Type N:
Measure the thickness of all non-conductive layers on non-ferromagnetic metal substrates such as copper, aluminum, stainless steel, etc., such as: paints, powders, various anti-corrosion coatings, plastics, rubber, synthetic materials, phosphate layers, oxide layers, etc.;
The full range of QNIX Thickness Gauges from Nix, Germany
| Model | 4200/4200P | 4500/4500P | 1200 | 1500 | 7500 | 8500 |
| Matrix | Fe | Fe/NFe | Fe | Fe/NFe | Fe、NFe、Fe/NFe | Fe/NFe |
| Probe form | One, separate | One | One, separate | Wired/wireless split | ||
| Measuring range | 0-3000μm 0-5000um | Fe:0-3000μm 0-5000um NFe:0-3000μm | 0-2000μm | 0-5000μm | 0-2000μm 0-5000μm (Optional) | |
| Measurement accuracy | 0-50μm:≤±1μm;50-1000μm:≤±1.5%;1000-2000μm:≤±2%;2000-5000μm:≤±3% | |||||
| Display accuracy | 0.1μm | 0-99μm: 0.1μm, 100μm-999um: 1um, 0.01mm above 999um | 0.1um/0.01um(Optional) | |||
| Operating temperature | -10 - +60℃ | |||||
| Temperature compensation | 0-50℃ | |||||
| Storage | - | Model 1500M | Model 7500M | Model 8500M | ||
| 3900 measurements, 999 data sets | 9999 readings, 100 data sets | |||||
| Statistical functions | - | Mean, Large, Small, Standard Deviation | ||||
| Overrun alarm | - | Upper and lower limits | ||||
| Small substrates | 10mm×10mm | |||||
| Small curvature | Convex and concave radius: 3mm/25mm | Convex radius: 5mm, concave radius: 25mm | ||||
| Thin matrix | Fe:0.2mm,NFe:0.05mm | |||||
| Electricity | 2 No. 5 batteries | 1 9V alkaline battery | 2 No. 5 batteries | |||
| Weight | 110g | 130g | 150g | 130g | ||
| Size | 110×60×27mm | 166×64×34mm | 110×60×24mm | 124mm×67mm×33mm | ||
Qnix QNix4500P5 Coating Thickness GaugeSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | Magnetic Induction + eddy Current |
| Measurement range | Fe:0~5000μm;NFe:0~3000μm |
| margin of error | ±3% |
| resolution | 0.1μm|1μm |
| Minimum measurement surface | Φ25mm |
| Minimum radius of curvature | Convex 5mm; Concave 25mm |
| thinnest substrate | 0.2mm(F);0.05mm(N) |
| probe | Split probe |
| Probe material | ruby |
| Unit display | μm/mils |
| Power Supply | 2 × 1.5V AA battery |
| Standards | DIN EN ISO 2808, ISO 2178, ASTM B 499, ASTM D 7091,SO 2360 |
| system language | German, English |
| Display screen | LCD screen |
| Operating temperature | -10~60℃ |
| Weight | 105g |
| Dimension | 100*60*27mm |
Qnix QNix4500P5 Coating Thickness Gauge Packing list
Host X1, probe X1, user manual X1, plastic outer box X1, Calibration plate X1, 1.5V battery X2, test certificate X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Principle and application analysis of wood paints Thickness Gauge
- Handheld coating Thickness Gauge several important application fields
- Application of Coating Thickness Gauge on Galvanized Steel Sheet
- Why Use Coating Thickness Gauges in Powder Coatings?
- How does the QNix Coating Thickness Gauge maintain accuracy?
- Analysis of Thickness Measurement Method for Coating Thickness Measurement
- Application of QNix Coating Thickness Gauge in coating Film thickness measurement
- Which Coating Thickness Gauge is Right for You?
- How is the surface profile of precast concrete measured?
- Film coating thickness measurement in industrial painting and cissing coating
- ActiveGB/T 44757-2024
- ActiveJJG 818-2018
- ActiveGB/T 1727-2021
- ActiveHG/T 20720-2020
- ActiveHG/T 5367.1-2018
- ActiveASTM B244-2021
- ActiveISO 2360-2017
- ActiveISO 2178-2016
- ActiveASTM D7091-2022
- ActiveASTM B499-2021
- ActiveISO 19840-2012
- ActiveGB/T 1740-2007
- ASTM E376-2019
- ActiveISO 2808-2019
- AbolishJJG 889-1995
- AbolishJJG 818-1993
- ActiveGB/T 4956-2003
- ISO 2361-1982
- AbolishISO 4042-1999
- ActiveHG/T 3885-2006


QNix4500P5