Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Coating Thickness Gauge> Qnix> Qnix QNix4500P5 Coating Thickness Gauge
      Qnix QNix4500P5 Coating Thickness Gauge

      Germany Knix QNix4500P/5 paints Thickness Gauge magnetic Induction/eddy Current thickness measurement 5/3mm

      The German Nix QNix4500P/5 paints Thickness Gauge has magnetic Induction and eddy Current two cladding thickness measurement modes, the measurement of paint thickness is 0~5mm and 0~3mm, QNix4500P/5 is split strip type, QNix4500 paints Thickness Gauge with ruby probe, can automatically identify the substrate.

      Brand
      SKU: NB016675
      Germany Qnix
      Stock
      Loading…
      Price
      Please contact customer service
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • Qnix QNix4500P5 Coating Thickness GaugeOverview

        • Specifications
        • Comments
        • FAQs
        QNix4500P5
        Coating Thickness Gauge

        QNix@4500 coating Thickness Gauge is widely used in the field of coatings and automotive coatings, QNix@4500 is a magnetic induction and eddy current dual-purpose coating Thickness Gauge, this model is a standard version of the integrated probe, can not only be used to measure magnetic substrates such as steel, but also can be used to measure aluminum, copper, stainless steel and other non-magnetic metal surface coatings, oxide film, phosphate film and other coatings. These two models are simple to operate, easy to carry, and have high precision, which are loved by the majority of users.

        German Nix QNix4500P/5 paint Thickness Gauge display

        Benefits:

        1. Simple and fast measurement

        2. No calibration is required

        3. Automatic power on/off

        4. Large range FE: 0-5000um NFE: 0-3000um

        5. Dual-purpose probe, cost-effective

        6. Hall sensor makes the measurement more stable

        7. The sound is synchronized during measurement

        8. Ruby wear-resistant head, long life

        9. Backlight LED display, the reading is clearer

        10、Automatic recognition of the measurement substrate

        11. Split probe to meet different measurement environments

        Product Applications

        Type F:

        Measure the thickness of non-magnetic coating layers on ferromagnetic metal substrates such as steel and iron, such as: paints, powders, various anti-corrosion coatings, plastics, rubber, synthetic materials, phosphating layers, chromium, zinc, lead, tin, cadmium, etc.;

        Type N:

        Measure the thickness of all non-conductive layers on non-ferromagnetic metal substrates such as copper, aluminum, stainless steel, etc., such as: paints, powders, various anti-corrosion coatings, plastics, rubber, synthetic materials, phosphate layers, oxide layers, etc.;

        The full range of QNIX Thickness Gauges from Nix, Germany

        Model4200/4200P4500/4500P1200150075008500
        MatrixFeFe/NFeFeFe/NFeFe、NFe、Fe/NFeFe/NFe
        Probe formOne, separateOneOne, separateWired/wireless split
        Measuring range

        0-3000μm

        0-5000um

        Fe:0-3000μm

        0-5000um

        NFe:0-3000μm 

        0-2000μm0-5000μm

        0-2000μm

        0-5000μm

        (Optional)

        Measurement accuracy0-50μm:≤±1μm;50-1000μm:≤±1.5%;1000-2000μm:≤±2%;2000-5000μm:≤±3%
        Display accuracy0.1μm0-99μm: 0.1μm, 100μm-999um: 1um, 0.01mm above 999um0.1um/0.01um(Optional)
        Operating temperature-10 - +60℃
        Temperature compensation0-50℃
        StorageModel 1500MModel 7500MModel 8500M
        3900 measurements, 999 data sets9999 readings, 100 data sets
        Statistical functionsMean, Large, Small, Standard Deviation
        Overrun alarmUpper and lower limits
        Small substrates10mm×10mm
        Small curvatureConvex and concave radius: 3mm/25mmConvex radius: 5mm, concave radius: 25mm
        Thin matrixFe:0.2mm,NFe:0.05mm
        Electricity2 No. 5 batteries1 9V alkaline battery
        2 No. 5 batteries
        Weight110g130g150g130g
        Size110×60×27mm166×64×34mm110×60×24mm124mm×67mm×33mm
        VS

        Qnix QNix4500P5 Coating Thickness GaugeSpecifications

        LIST VALUE
        Measurement principle Magnetic Induction + eddy Current
        Measurement range Fe:0~5000μm;NFe:0~3000μm
        margin of error ±3%
        resolution 0.1μm|1μm
        Minimum measurement surface Φ25mm
        Minimum radius of curvature Convex 5mm; Concave 25mm
        thinnest substrate 0.2mm(F);0.05mm(N)
        probe Split probe
        Probe material ruby
        Unit display μm/mils
        Power Supply 2 × 1.5V AA battery
        Standards DIN EN ISO 2808, ISO 2178, ASTM B 499, ASTM D 7091,SO 2360
        system language German, English
        Display screen LCD screen
        Operating temperature -10~60℃
        Weight 105g
        Dimension 100*60*27mm

        Qnix QNix4500P5 Coating Thickness Gauge Packing list

        Host X1, probe X1, user manual X1, plastic outer box X1, Calibration plate X1, 1.5V battery X2, test certificate X1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        QNix4500P5 Coating thickness gauge can measure anti-corrosion coatings coatings, relatively thick?
        [A]
        Yes, this one is magnetic Induction + eddy Current Coating thickness gauge. The range is up to 5mm (iron) 3mm (aluminum).
        [Q]
        Do you have the Coating thickness gauge involved in ASTMB499?
        [A]
        The QNix4500P5 Coating thickness gauge will do
        [Q]
        Does the Nix QNix4500P/5 come with two probes or one probe?
        [A]
        Hello, it is equipped with a dual-function thickness probe, which can automatically identify the substrate.
        [Q]
        Excuse me, why is my Nix 4500 thickness gauge adjusted to zero and then tested not to be zero?
        [A]
        Hello, if it is tested on an object with a rough surface of the workpiece, this will happen. This is a normal phenomenon.
        Qnix
        Germany Knix QNix4500P/5 paints Thickness Gauge magnetic Induction/eddy Current thickness measurement 5/3mm
        Service
        Focus on online sales of Lab Testing Instruments