      Home> Coating Thickness Gauge> Qnix> Qnix QNix 1500 Coating Thickness Gauge
      Qnix QNix 1500 Coating Thickness Gauge

      German Knicks QNix1500 dual-use Thickness Gauge, iron-based/non-iron-based 0~2mm/5mm

      The German Nix QNix1500 has two thickness measurement principles of magnetic Induction and eddy Current, and the thickness measurement range is 0~2000μm (NFe)/5000μm (Fe). The QNix 1500 dual-use Thickness Gauge has Data storage and transmission functions.

      Brand
      SKU: NB016680
      Germany Qnix
      VS
      Information
      Genuinegoods
      • Qnix QNix 1500 Coating Thickness GaugeOverview

      • Specifications
      • Comments
      • FAQs
      QNix 1500
      Coating Thickness Gauge

      Introduction

      The QNix1200 and QNix1500 models are all-in-one and only need to be zeroed and calibrated, making them very easy to use. Among them, QNix1200 is a magnetic Thickness Gauge, which can be used to measure the coating and plating on magnetic substrates such as steel and iron; The QNix1500 is a magnetic and eddy current Thickness Gauge, which can be used to measure not only magnetic substrates such as steel, but also coatings, oxide films, phosphate films and other cladding on the surface of non-magnetic metals such as aluminum, copper and stainless steel. These two models are simple to operate, easy to carry, high precision, and the probe and body are designed at a 90° right angle, which can meet the measurement of some narrow spaces (such as the inner wall of the pipe), and are loved by the majority of users.

      Benefits:

      Simple and easy to use

      • All-in-one design, only need to be zeroed, no calibration required

      • High-low limit indication signs

      • Factory calibrated and ready to use out of the pack

      Accurate readings

      • Measurement accuracy±1%

      • Dual-probe dual-purpose

      • Measurement of coatings and plating on magnetic substrates such as steel and iron

      • Comply with a number of national and national standards

      Reliable measurements

      • The probe is designed at a 90° right angle to the body

      • It can meet the measurement of some small spaces (such as the inner wall of pipes).

      • Provide a full set of traceable inspection certificates

      sturdy

      • Sealed, durable, and impact-resistant

      • Instrument and probe construction is durable

      • Suitable for use in harsh environments

      effective

      • Automatic power on/off

      • The right-angle design of the probe is convenient for measuring tight spaces such as the inner wall of the tube

      Product display diagram

      German Nix QNix1500 dual-purpose Thickness Gauge display drawing

      VS

      Qnix QNix 1500 Coating Thickness GaugeSpecifications

      LIST VALUE
      Measurement principle Magnetic Induction + eddy Current
      Measurement range 0~5000μm
      margin of error ≤1000μm:±(1+2%)μm、>1000μm:±3.5%
      resolution 0.1μm|1μm|0.01mm
      Minimum measurement surface 10*10mm
      Minimum radius of curvature Convex 5mm/Concave 25mm
      thinnest substrate 0.2mm(F);0.05mm(N)
      probe Integrated probe
      statistical function Average value, max value, small value, standard deviation
      Data storage 3900 measurements, 999 data sets
      Power Supply 1 9V alkaline battery
      system language English
      Display screen LCD liquid crystal
      Weight 50g
      Dimension 166*64*34mm
      Storage temperature -10~60℃
      temperature compensation 0~50℃
      Interface Connect a computer or printer via USB and RS232 interfaces

      Qnix QNix 1500 Coating Thickness Gauge Packing list

      machine X1, manual X1, certificate X1, warranty card X1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Can QNix 1500 Coating thickness gauge be used to test anti-corrosion coatings?
      [A]
      Yes, this is a magnetic Induction + eddy Current Coating thickness gauge. The range is 5mm.
      [Q]
      The detection object is aluminum anode parts and mg aluminum alloy parts. Is this okay?
      [A]
      OK
      [Q]
      Does the Qnix Coating thickness gauge meet the ASTMB244 standard?
      [A]
      Coating thickness gauge of the QNix 1500 can be referred to
      [Q]
      Does the QNix1500 Coating thickness gauge have a temperature compensation function?
      [A]
      Hello, yes, it has its own temperature compensation function, and the temperature range is 5 ° C~ 50 ° C.
      [Q]
      Which Nix Coated Thickness Gauge has a Right Angle Probe?
      [A]
      Hello, the QNIX 1500 Coating thickness gauge is designed with a right angle probe.
      +Qnix QNix 1500 Coating Thickness Gauge Big data
        +Qnix QNix 1500 Coating Thickness GaugeSimilar products
        +Qnix QNix 1500 Coating Thickness GaugeKnowledge
        +Qnix QNix 1500 Coating Thickness GaugeStandard
        +Navigation
        Qnix
        German Knicks QNix1500 dual-use Thickness Gauge, iron-based/non-iron-based 0~2mm/5mm
        Service
        Focus on online sales of Lab Testing Instruments