German Knicks QNix8500 paints Thickness Gauge, with iron-based probe 0~2mm range
QNix8500 paints Thickness Gauge with magnetic probe, the thickness range is 0~2000μm, is a German imported Thickness Gauge, QNix8500 paints Thickness Gauge
Qnix-
LANDTEK CM8829Fn Coating Thickness Gauge, integrated paints Thickness Gauge Film Thickness Gauge
$ 386.00 -
Defelsko PosiTector 200 B1 Wood/plastic polymer Coating Thickness Gauge
$ 2692.00 -
YIBAI CTG-600F10 Single iron Coating Thickness Gauge 10mm
$ 344.00 -
German EPK MiniTest 735 F1.5 statistical coating Thickness Gauge, thickness measurement 0~1500μm
$ 2247.00 -
Germany Nix QNix 4500 + FN1.2 integrated dual-use coating platings Thickness Gauge FeNFe dual-use probe 0-1200μm
$ 863.00
Introduction
The QNix8500 Coating Thickness Gauge is an all-in-one, one-piece, universal with menu operation, and is an intelligent Thickness Gauge. Probes can be replaced to meet different measurement needs, data can be stored, and can be wirelessly transferred to a computer. The probe can be directly connected to the host computer for integrated measurement, or it can be connected to the host computer through the probe cable for split measurement. The operation of split measurement is simple, and the error caused by misoperation can be avoided to a large extent. The instrument is universal, and the probe is divided into magnetic probe, eddy current probe and dual-purpose probe, and the measurement range of the probe is 0-2mm and 0-5mm.
Features
Modular instrumentation system with interchangeable probes for a maximum measuring range of up to 5,000 μm
The thumb-sized wireless probe allows for use in hard-to-reach areas
Pen probes for small parts and thin coatings
High measurement speed (up to 120 readings/min)
Memory capacity up to 30,000 cycles and up to 200 batches
Software for statistical analysis and documentation
Optional protective rubber cover for increased vibration sensitivity

In addition, the QNix coating Thickness Gauge has the following advantages:
Easy to use
No calibration is required
High measurement accuracy
Long-lasting measuring probe with ruby tip
Made in Germany, boutique quality

Probes are optional
| probe | fe2mm | Fe iron-based probe (0-2000um) |
| probe | RF2mm | RF Iron-based Wireless Probe (0-2000um) |
| probe | fe5mm | Fe iron-based probe (0-5000um) |
| probe | RF5mm | RF Iron-based Wireless Probe (0-5000um) |
| probe | NFe2mm | NFe non-ferrous probe (0-2000um) |
| probe | RF2mm | RF Non-ferrous Wireless Probe (0-2000um) |
| probe | Fe/NFe2mm | Fe/NFe iron/non-iron/non-iron-based dual-purpose probes (0-2000um) |
| probe | RF dual-purpose probe 2mm | RF dual-purpose wireless probe (0-2000um) |
| probe | Fe/NFe5mm | Fe/NFe Iron/Non-Iron/Non-Iron/Non-Ferrous Probes (0-5000um) |
| probe | RF dual-purpose probe 2mm | RF dual-purpose probe (0-5000um) |
| probe | MI 0.5mm | MI Slim Probe (0-500um) |
| fittings | Probe leads | Probe wire (the cable between the main unit and the probe) |
| fittings | Dangle | Dangle (USB module for wireless transmission of computer data, transmission module for connecting host and computer) |
| fittings | Computer software | Computer Software (System Processing Software) |
Qnix QNix8500+Fe 2mm Coating Thickness GaugeSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | magnetic Induction |
| Measurement range | 0~2000μm |
| margin of error | ±2% |
| resolution | 0.1μm|1μm|0.01mm |
| Minimum measurement surface | Fe:10mm*10mm NFe:6mm*6mm |
| thinnest substrate | 0.2mm(F);0.05mm(N) |
| probe | Integrated probe |
| Calibrated mode | One point calibrated, two point calibrated, zero calibrated |
| statistical function | Single measurement, continuous measurement |
| Unit display | μm/mils |
| statistical function | MAX Maximum, MIN Minimum, Average, Standard deviation |
| Interface | USB |
| Data storage | 100 Measured value * 1 batch |
| Power Supply | 2 1.5V dry batteries |
| system language | German, English |
| Display screen | LCD screen |
| Operating temperature | 0~50℃ |
| Weight | 120G (including battery and probe) |
| Dimension | 124*67*33mm |
Qnix QNix8500+Fe 2mm Coating Thickness Gauge Packing list
host X1, probe x1, probe cable x1, operation manual X1, certificate of conformity X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Principle and application analysis of wood paints Thickness Gauge
- QNIX 8500 Coating Thickness Gauge Real Photo Appreciation
- Handheld coating Thickness Gauge several important application fields
- Concept and basic knowledge of coating Thickness Gauge
- How does the QNix Coating Thickness Gauge maintain accuracy?
- Analysis of Thickness Measurement Method for Coating Thickness Measurement
- Optimizing laboratory management and paint production with Qnix8500 coated Film thickness measurement technology
- How is the surface profile of precast concrete measured?
- Application of Coating Thickness Gauge on Galvanized Steel Sheet
- Why Use Coating Thickness Gauges in Powder Coatings?
- ActiveQJ 990.3A-2011
- ActiveGB/T 7991.5-2014
- ActiveJJG 818-2018
- ActiveGB/T 1727-2021
- ActiveHG/T 20720-2020
- ActiveSY/T 0315-2013
- ActiveISO 2178-2016
- ActiveASTM B499-2021
- ActiveISO 19840-2012
- ActiveGB/T 1740-2007
- ASTM E376-2019
- ActiveISO 2808-2019
- AbolishJJG 889-1995
- ActiveGB/T 4956-2003
- ISO 2361-1982
- ActiveGB/T 6463-2005
- AbolishGB/T 4956-1985
- AbolishASTM G12-07-2013
- ActiveJB/T 7217-2008
- ActiveJB/T 7663.2-2007


QNix8500+Fe 2mm