Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Coating Thickness Gauge> Qnix> Qnix QNix8500+Fe 2mm Coating Thickness Gauge

      German Knicks QNix8500 paints Thickness Gauge, with iron-based probe 0~2mm range

      QNix8500 paints Thickness Gauge with magnetic probe, the thickness range is 0~2000μm, is a German imported Thickness Gauge, QNix8500 paints Thickness Gauge

      Brand
      SKU: NB016681
      Germany Qnix
      VS
      Genuinegoods
      • Qnix QNix8500+Fe 2mm Coating Thickness GaugeOverview

      • Specifications
      • Comments
      • FAQs
      QNix8500+Fe 2mm
      Coating Thickness Gauge

      Introduction

      The QNix8500 Coating Thickness Gauge is an all-in-one, one-piece, universal with menu operation, and is an intelligent Thickness Gauge. Probes can be replaced to meet different measurement needs, data can be stored, and can be wirelessly transferred to a computer. The probe can be directly connected to the host computer for integrated measurement, or it can be connected to the host computer through the probe cable for split measurement. The operation of split measurement is simple, and the error caused by misoperation can be avoided to a large extent. The instrument is universal, and the probe is divided into magnetic probe, eddy current probe and dual-purpose probe, and the measurement range of the probe is 0-2mm and 0-5mm.

      Features

      • Modular instrumentation system with interchangeable probes for a maximum measuring range of up to 5,000 μm

      • The thumb-sized wireless probe allows for use in hard-to-reach areas

      • Pen probes for small parts and thin coatings 

      • High measurement speed (up to 120 readings/min)

      • Memory capacity up to 30,000 cycles and up to 200 batches

      • Software for statistical analysis and documentation

      • Optional protective rubber cover for increased vibration sensitivity

      Illustration of the QNix8500 paint Thickness Gauge from Nix, Germany

      In addition, the QNix coating Thickness Gauge has the following advantages:

      • Easy to use

      • No calibration is required

      • High measurement accuracy

      • Long-lasting measuring probe with ruby tip

      • Made in Germany, boutique quality

      Application scenarios for the QNix8500 paint Thickness Gauge from Nix


      Probes are optional

      probefe2mmFe iron-based probe (0-2000um)
      probeRF2mmRF Iron-based Wireless Probe (0-2000um)
      probefe5mmFe iron-based probe (0-5000um)
      probeRF5mmRF Iron-based Wireless Probe (0-5000um)
      probeNFe2mmNFe non-ferrous probe (0-2000um)
      probeRF2mmRF Non-ferrous Wireless Probe (0-2000um)
      probeFe/NFe2mmFe/NFe iron/non-iron/non-iron-based dual-purpose probes (0-2000um)
      probeRF dual-purpose probe 2mmRF dual-purpose wireless probe (0-2000um)
      probeFe/NFe5mm Fe/NFe Iron/Non-Iron/Non-Iron/Non-Ferrous Probes (0-5000um)
      probeRF dual-purpose probe 2mmRF dual-purpose probe (0-5000um)
      probeMI 0.5mmMI Slim Probe (0-500um)
      fittingsProbe leadsProbe wire (the cable between the main unit and the probe)
      fittingsDangleDangle (USB module for wireless transmission of computer data, transmission module for connecting host and computer) 
      fittingsComputer softwareComputer Software (System Processing Software)
      VS

      Qnix QNix8500+Fe 2mm Coating Thickness GaugeSpecifications

      LIST VALUE
      Measurement principle magnetic Induction
      Measurement range 0~2000μm
      margin of error ±2%
      resolution 0.1μm|1μm|0.01mm
      Minimum measurement surface Fe:10mm*10mm NFe:6mm*6mm
      thinnest substrate 0.2mm(F);0.05mm(N)
      probe Integrated probe
      Calibrated mode One point calibrated, two point calibrated, zero calibrated
      statistical function Single measurement, continuous measurement
      Unit display μm/mils
      statistical function MAX Maximum, MIN Minimum, Average, Standard deviation
      Interface USB
      Data storage 100 Measured value * 1 batch
      Power Supply 2 1.5V dry batteries
      system language German, English
      Display screen LCD screen
      Operating temperature 0~50℃
      Weight 120G (including battery and probe)
      Dimension 124*67*33mm

      Qnix QNix8500+Fe 2mm Coating Thickness Gauge Packing list

      host X1, probe x1, probe cable x1, operation manual X1, certificate of conformity X1, warranty card X1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Meet ISO19840 Coating thickness gauge
      [A]
      QNix8500 + Fe 2mm Coating thickness gauge, please refer to it.
      [Q]
      Can the QNix8500 paint thickness gauge test Miscellaneous products without changing the host and the probe?
      [A]
      Hello, yes, the probe test of Miscellaneous application range can be replaced.
      [Q]
      Do I need to calibrate the QNix8500 thickness gauge before testing?
      [A]
      Hello, no need to calibrate.
      +Qnix QNix8500+Fe 2mm Coating Thickness Gauge Big data
        +Qnix QNix8500+Fe 2mm Coating Thickness GaugeSimilar products
        +Qnix QNix8500+Fe 2mm Coating Thickness GaugeKnowledge
        +Qnix QNix8500+Fe 2mm Coating Thickness GaugeStandard
        +Navigation
        Qnix
        German Knicks QNix8500 paints Thickness Gauge, with iron-based probe 0~2mm range
        Service
        Focus on online sales of Lab Testing Instruments