German Nix QNix8500 nonmagnetic Thickness Gauge, with wireless non-ferrous probe 0~2mm range
The German Nix QNix8500 nonmagnetic Thickness Gauge is equipped with a wireless NFe probe, with a thickness range of 0~2000μm. The QNix8500 nonmagnetic Thickness Gauge can store 30,000 readings and uses a large LCD screen, which is intuitive and clear.
Qnix-
Defelsko F probe, thickness measurement range from 0 to 1500 μm
$ 548.00 -
AMITTARI USB data cable, which can be connected to most AMITTARI series test instruments through the RS-232 software system
$ 108.00 -
KAIRDA N1 standard probe eddy Current NDT530 Coating Thickness Gauge optional probe
$ 173.00 -
LANDTEK CM-1210-200F Coating Thickness Gauge
$ 568.00 -
LANDTEK CM8825Fn platings Thickness Measurement Instrument Dual function coating Thickness Measurement Instrument
$ 386.00
Introduction
The QNix8500 Coating Thickness Gauge is an all-in-one, one-piece, universal with menu operation, and is an intelligent Thickness Gauge. Probes can be replaced to meet different measurement needs, data can be stored, and can be wirelessly transferred to a computer. The probe can be directly connected to the host computer for integrated measurement, or it can be connected to the host computer through the probe cable for split measurement. The operation of split measurement is simple, and the error caused by misoperation can be avoided to a large extent. The instrument is universal, and the probe is divided into magnetic probe, eddy current probe and dual-purpose probe, and the measurement range of the probe is 0-2mm and 0-5mm.
Features
Modular instrumentation system with interchangeable probes for a maximum measuring range of up to 5,000 μm
The thumb-sized wireless probe allows for use in hard-to-reach areas
Pen probes for small parts and thin coatings
High measurement speed (up to 120 readings/min)
Memory capacity up to 30,000 cycles and up to 200 batches
Software for statistical analysis and documentation
Optional protective rubber cover for increased vibration sensitivity

In addition, the QNix coating Thickness Gauge has the following advantages:
Easy to use
No calibration is required
High measurement accuracy
Long-lasting measuring probe with ruby tip
Made in Germany, boutique quality

Probes are optional
| probe | fe2mm | Fe iron-based probe (0-2000um) |
| probe | RF2mm | RF Iron-based Wireless Probe (0-2000um) |
| probe | fe5mm | Fe iron-based probe (0-5000um) |
| probe | RF5mm | RF Iron-based Wireless Probe (0-5000um) |
| probe | NFe2mm | NFe non-ferrous probe (0-2000um) |
| probe | RF2mm | RF Non-ferrous Wireless Probe (0-2000um) |
| probe | Fe/NFe2mm | Fe/NFe iron/non-iron/non-iron-based dual-purpose probes (0-2000um) |
| probe | RF dual-purpose probe 2mm | RF dual-purpose wireless probe (0-2000um) |
| probe | Fe/NFe5mm | Fe/NFe Iron/Non-Iron/Non-Iron/Non-Ferrous Probes (0-5000um) |
| probe | RF dual-purpose probe 2mm | RF dual-purpose probe (0-5000um) |
| probe | MI 0.5mm | MI Slim Probe (0-500um) |
| fittings | Probe leads | Probe wire (the cable between the main unit and the probe) |
| fittings | Dangle | Dangle (USB module for wireless transmission of computer data, transmission module for connecting host and computer) |
| fittings | Computer software | Computer Software (System Processing Software) |
Qnix QNix8500+NFe RF2mm Coating Thickness GaugeSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | eddy Current |
| Measurement range | 0~2000μm |
| margin of error | ±2% |
| resolution | 0.1μm|1μm|0.01mm |
| Minimum measurement surface | Fe:10mm*10mm NFe:6mm*6mm |
| thinnest substrate | 0.2mm(F);0.05mm(N) |
| probe | Integrated probe |
| Calibrated mode | One point calibrated, two point calibrated, zero calibrated |
| statistical function | Single measurement, continuous measurement |
| Unit display | μm/mils |
| statistical function | MAX Maximum, MIN Minimum, Average, Standard deviation |
| Interface | USB |
| Data storage | 100 Measured value * 1 batch |
| Power Supply | 2 1.5V dry batteries |
| system language | German, English |
| Display screen | LCD screen |
| Operating temperature | 0~50℃ |
| Weight | 120G (including battery and probe) |
| Dimension | 124*67*33mm |
Qnix QNix8500+NFe RF2mm Coating Thickness Gauge Packing list
Host X1, probe X1, operation manual X1, certificate of conformity X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- QNIX 8500 Coating Thickness Gauge Real Photo Appreciation
- Film coating thickness measurement in industrial painting and cissing coating
- Handheld coating Thickness Gauge several important application fields
- Application of QNIX Thickness Gauge in coated Film thickness measurement
- Which Coating Thickness Gauge is Right for You?
- How does the QNix Coating Thickness Gauge maintain accuracy?
- Why Use Coating Thickness Gauges in Powder Coatings?
- Concept and basic knowledge of coating Thickness Gauge
- Optimizing laboratory management and paint production with Qnix8500 coated Film thickness measurement technology
- Analysis of Thickness Measurement Method for Coating Thickness Measurement
- ActiveGB/T 44757-2024
- ActiveQJ 990.3A-2011
- ActiveJJG 818-2018
- ActiveGB/T 1727-2021
- ActiveGB/T 12967.1-2020
- ActiveHG/T 20720-2020
- ActiveASTM B244-2021
- ActiveISO 2360-2017
- ActiveASTM D7091-2022
- ASTM E376-2019
- AbolishJJG 818-1993
- ActiveHG/T 3885-2006
- ActiveGB/T 6463-2005
- ActiveGB/T 13452.2-2008
- ActiveGB/T 11374-2012
- ActiveGB/T 4957-2003


QNix8500+NFe RF2mm