Germany EPK MikroTest F6 McCourt Coating Thickness Gauge: 0~1000μm
The German EPK MikroTest F6 McCourt Coating Thickness Gauge is an explosion-proof mechanical Coating Thickness Gauge for the measurement of the thickness of paints and platings on steel, MikroTest F6 is suitable for curved and underwater measurement, using the principle of magnetic attraction thickness measurement, no need to calibrate.
ElektroPhysik-
Coating Thickness Gauge AMITTARI AC-112H Special magnetic Induction Coating Thickness Gauge
$ 599.00 -
CHINA CTG-800-3000FN Coating Thickness Gauge integrated dual-use standard type
$ 218.00 -
German EPK MiniTest 600 B-F magnetic platings Thickness Gauge, thickness: 0~3000μm
$ 846.00 -
HT2916 Ultrasonic Coating thickness gauge Simultaneous measurement of multi-layer thickness, Non-metallic/metallic coating thickness
$ 1090.00 -
Defelsko PosiTector 6000 F90S1 Coating Thickness Gauge 90 ° Miniature probe
$ 1266.00
Introduction
The German EPK MikroTest F6 McCourt Coating Thickness Gauge accurately and error-free measures the thickness of paint and plating layers on steel.
MIKROTEST Coating Thickness Gauges measure the thickness of all non-magnetic coatings on steel (e.g. paint, powder coating, plastic, zinc, copper, tin and nickel). Fast, accurate and non-destructive, MICROTEST has been the most widely used instrument for the automatic determination of coating thickness for more than 30 years. Germany's "know-how" shows that it has the highest level of magnetic cladding Thickness Gauge in terms of process technology and precision.
Features
MIKROTEST has the following features and advantages:
1) Automatic measurement will not occur misoperation;
2) Simple setup and measurement;
3)No calibration required;
4)No batteries or other power sources are required;
5)Automatically report the thickness reading;
6)With a non-destructive probe, a little bit of measurement;
7)The metal armor is suitable for frequent outdoor operation and use, and is protected from mechanical impact;
8)Resistant to mechanical shock, acid and solvent corrosion;
9)The balancing device eliminates the influence of gravity and can accurately measure in any direction and in the tube.
Apply standards
The EPK MikroTest F6 McCourt Coating Thickness Gauge complies with DIN EN ISO2178, DIN 50982, ASTM B 499, E 376, ASTM D 1186, ASTM G12, ASTM B 530, BS5411, ISO2361 standards.
Display diagram



Comparison of EPK MikroTest coating Thickness Gauge series
| Model | Measuring range | Readability | Minimum measuring area diameter | The minimum radius is convex and concave mm | Minimum thickness of the substrate | Suitable for: |
| MIKROTEST G 6 | 0-100μm | 1 μm or 5% reading | 20mm | 5mm;25mm | 0.5mm | Electroplating layer on steel, iron, lacquer, enamel, plastic, rubber layer |
| MIKROTEST F 6 | 0-1000μm | 5 μm or 5% reading | 30mm | 8mm;25mm | 0.5mm | |
| MIKROTEST S3 6 | 0.2-3mm | 5% reading | 30mm | 15mm;25mm | 1.0mm | |
| MIKROTEST S5 6 | 0.5-5mm | 5% reading | 50mm | 15mm;25mm | 1.0mm | |
| MIKROTEST S10 6 | 2.5-10mm | 5% reading | 50mm | 15mm;25mm | 2.0mm | |
| MIKROTEST S20 6 | 7.5-20mm | 5% reading | 100mm | 100mm;150mm | 7.0mm | |
| MIKROTEST NIFE50 6 | 0-50μm | 2 μm + 8% reading | 20mm | 10mm;25mm | 0.5mm | Nickel plating on iron |
| MIKROTEST NI50 | 0-50um | 1 μm or 5% reading | 15mm | 5mm;25mm | - | Nickel plating on a non-ferromagnetic metal substrate |
| MIKROTEST NI100 | 0-100um | 1 μm or 5% reading | 15mm | 5mm;25mm | - |
ElektroPhysik MikroTest F6 McCourt platings Thickness GaugeSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | mechanical |
| Measurement range | 0~1000μm |
| margin of error | +/- 5μm/5% read value |
| Minimum measurement surface | 30mm |
| Minimum radius of curvature | Convex 8mm; Concave 25mm |
| thinnest substrate | 0.5mm |
| probe | Integrated probe |
| Calibrated Certificate | none |
| Calibrated mode | No need to calibrate |
| Unit display | μm |
| statistical function | none |
| icon function | none |
| Interface | none |
| Data storage | none |
| Power Supply | No power or battery required |
| Standards | DIN EN ISO2178, DIN 50982, ASTM B 499, E 376, ASTM D 1186, ASTM G12, ASTM B 530, BS5411, ISO2361 standards |
| Display screen | dial |
| Operating temperature | -20~100℃ |
| Weight | 560G (including instrument case) |
| Dimension | 215*55*29mm |
| Packaging Dimensions | 235*185*46mm |
ElektroPhysik MikroTest F6 McCourt platings Thickness Gauge Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Can the coating Thickness Gauge measure the thickness of pipes?
- Precautions for the use of MiKroTest McCourt Mechanical Coating Thickness G6
- Application of Coating Thickness Gauge on Galvanized Steel Sheet
- Analysis of Thickness Measurement Method for Coating Thickness Measurement
- Why Use Coating Thickness Gauges in Powder Coatings?
- Which Coating Thickness Gauge is Right for You?


MikroTest F6