MODERNER NDJ-5T Rotational Viscometer 1~ 100,000 mPa · s viscosity range
Touch type, measurement range 1~ 100000mPa · s, rotor specifications 1 #, 2 #, 3 #, 4 #(0 #optional), Rotor speed 6/12/30/60rpm, reproducibility +/- 0.5% F. S, Power Supply 110V/60Hz or 220V/50Hz, data interface Standard temperature probe interface, Power Supply 110V/60Hz or 220V/50Hz.
Moderner-
HUINUO SNB-3 solder paste digital Rotational Viscometer 80 million cp with printer
$ 1345.00 -
MODERNER NDJ-8T Rotational Viscometer 1~ 2 million mPa · s viscosity
Login -
Fungilab Viscolead One L Rotational Viscometer 2 million cP
Login -
NIRUN 1000 series, standard solution (not sold separately)
$ 192.00 -
FANGRUI HADV-2T Digital Rotational Viscometer Viscosity range 200~80 million mPa·s
$ 1804.00
product description
MODERNER NDJ-5T touch-type Rotational Viscometer is well integrated into the touch-screen technology, and uses a fashionable and modern high-tech to measure viscosity quickly, accurately and conveniently. Powerful functions, far from comparable to previous liquid crystal display viscometers.
Self-built 30 sets of test procedures help users to quickly and accurately obtain the viscosity and related data of the sample. The 5-inch super-large color touch screen can comprehensively and vividly display various parameters and Operating Conditions. It has obvious advantages such as many measurement parameters, rich display content, convenient operation, intuitive reading, high measurement accuracy, stable speed, strong anti-interference performance, and wide working Voltage. It can completely replace the imported instruments of the same type, closely following the new technological trend of domestic (CN) viscometers.
main feature
① Using ARM technology, built-in Linux system. The operation interface is simple and clear, and the viscosity test can be performed quickly and conveniently through the creation of test programs and data analysis;
② Viscosity measurement is accurate, and each range is automatically calibrated by computer, with high precision and small error;
③ Rich display content: In addition to viscosity, there are also temperature, the percentage of the measured value to the full scale value (graphic display), range overflow alarm, automatic scanning, the maximum measurement range under the current rotor speed combination, date, time, etc. And it can display the kinematic viscosity when the density is known, which greatly meets the different measurement requirements of users;
④ Complete functions, can measure regularly, build 30 sets of test programs, store and retrieve 30 sets of measurement data, display viscosity curves in real time, print data and curves, etc.;
⑤ Front-mounted spirit level, intuitive and convenient level adjustment;
⑥ Optional temperature probe, constant temperature bath for viscometer, constant temperature cup, printer, standard viscosity sample (standard silicone oil), etc.;
⑦ Chinese and English operating system.
Applications
NDJ-5T touch screen viscometer can measure the absolute viscosity of Newtonian liquid or the apparent viscosity of non-Newtonian liquid.
It is widely used in various fluids that need to measure viscosity and fluids under high temperature melting. Including paints, coatings, cosmetics, inks, pulp, food, oil, starch, solvent-based adhesives, latex, biochemical products, etc., as well as industries that require high-temperature melting, such as asphalt, paraffin, hot-melt adhesives, etc.
plan

Viscometer test interface


Moderner NDJ-5T Touch Rotational ViscometerSpecifications
| LIST | VALUE |
|---|---|
| Display | touch type |
| Measuring range | 1~100000mPa·s |
| Rotor Specifications | 1 #, 2 #, 3 #, 4 #(0 #optional) |
| Rotor speed | 6/12/30/60rpm |
| Reproducibility | ±0.5%F.S |
| Power | 110V/60Hz 220V/50Hz |
| Interface | Standard temperature probe interface |
| Power | 110V/60Hz 220V/50Hz |
| Operating language | Chinese |
| Timer | Standard |
| Automatic scan function | Automatically scan and recommend the best combination of rotor and rotational speed |
| Display shear response/shear rate | Standard |
| Auto Display Motion Viscosity | Density to input sample |
| Save measurement results | Save up to 30 sets (including rotor, speed, temperature, time, etc.) |
| Save measurement results | Save up to 30 sets of data (including Viscosity, Temperature, Rotor, Speed, Shear Rate, Shear Stress, Time, Density, Motion Viscosity, etc.) |
| Viscosity Linear dispersion | Viscosity Linear dispersion in real time |
| Interface | Data, Linear dispersion printable (standard with print interface, optional printer required) |
Moderner NDJ-5T Touch Rotational Viscometer Packing list
Host X1, 1-4 #rotor X1,
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- IncomingGB/T 17001.3-2025
- ActiveJC/T 2316-2015
- ActiveHG/T 4443-2012
- ActiveHG/T 3323-2008
- ActiveDIN 53017-1993
- ActiveNF EN 12092-2002
- ActiveGB/T 24148.4-2009
- ActiveGB/T 21894-2008
- ActiveGB/T 17001.6-2022
- ActiveGB/T 13217.4-2020
- ActiveHG/T 3948-2007
- ActiveGB/T 12009.3-2009
- ActiveASTM D3794-2022
- ActiveISO 12634-2017
- ActiveJJG 1002-2005
- ActiveGB/T 22427.7-2008
- ActiveGB/T 12004.4-2003
- ActiveGB/T 18856.4-2008
- ActiveSN/T 2903-2011
- ActiveGB/T 17473.5-2008


NDJ-5T