TIMEPOWER TP151 dissolved oxygen analyzer, water quality oxygen content Detector
TIMEPOWER-
TONGAO TR-308H COD Ammonia Nitrogen Total Phosphorus Turbidity Tester Water Quality Analyzer
$ 3149.00 -
TDS standard solution 71.8 ppm, 480 ml
$ 102.00 -
JINGQI WD8802 residual chlorine analyzer
$ 481.00 -
JINGQI BOD5-870 Direct reading BOD Tester
$ 722.00 -
DDKSIC PD100T desktop pH, Dissolved Oxygen Meter (touch screen) pH/mV (ORP electrode optional)/DO/℃
$ 929.00
Introduction
TP151 dissolved oxygen monitor has the characteristics of Chinese menu operation, full intelligence, multi-function, high measurement performance, etc., which can be used to measure trace dissolved oxygen in solutions in various industries.

Features
The short response time of the electrode is convenient for the measurement of water samples with high oxygen content of sewage
Professional chip placement process, highly integrated circuit design is stable and durable
Professional microcontroller technology, high performance, low power consumption
24-bit A/D signal acquisition, high-precision measurement, accurate and reliable
Chinese main menu operation, easy to understand, quick and convenient operation
The standard output signal type is optional, and the alarm relay can be set arbitrarily
Data cycle storage function, automatic removal of overflow data, simple operation, convenient query, power failure data storage time of more than 10 years
TIMEPOWER TP151 Dissolved oxygen analyzerSpecifications
| LIST | VALUE |
|---|---|
| Display | 128 * 64 LCD, Chinese display |
| Measurement range | 0.00~20.00mg/L |
| Accuracy | ±1.5%FS |
| Resolution | 0.01mg/L |
| Repeatability | ≤1% |
| Temperature sensor | PT1000 |
| Response time | T90<5min (25℃) |
| Temperature compensation range | 0~60℃ |
| Water sample temperature | 5~60℃ |
| Environmental temperature | 5~45℃ |
| Working Relative Humidity | ≤ 90RH (non-condensing) |
| Storage temperature | -25~ 55 ℃ (electrode should be higher than 0 ℃) |
| Power Supply | AC (85~ 265) V Frequency (45~ 65) Hz |
| current output | 0~10mA, 0~20mA, 4~ 20mA optional, load < 300Ω |
| Alarm relay | AC220V 3A /DC30V 3A |
| power consumption | ≤15W |
| Protection level | IP65 |
| Dimensions | 145*120*150mm |
| opening size | 138*138mm |
| Weight | 0.64kg |
TIMEPOWER TP151 Dissolved oxygen analyzer Packing list
Host X1, dissolved oxygen composite electrode X1, sewage electrode flow tank X1, main board X1, online shell X1, fine steel wire X1, electrode extension wire X1, electrode film head X1, pipeline mounting kit X1, flange mounting kit X1, 1 meter submerged kit X1, 1 meter extension tube kit X1,
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJF 1714-2018
- ActiveJJF 1441-2013
- ActiveJJG 2104-2024
- AbolishGB/T 12157-2007
- ActiveGB/T 20245.4-2013
- ActiveGB/T 12157-2022
- ActiveHJ 2515-2012


TP151