TIMEPOWER TP110 (Sewage) PH Analyzer
TIMEPOWER-
LEICI 962244 Slender pH composite electrode is suitable for micro samples above 0.2mL, or fine diameter containers
$ 242.00 -
YueFeng PHBJ-260 Portable Acidity Meter 0~18.0pH
$ 207.00 -
LEICI PF-2-01 Fluorine ion electrode range 10-1~ 5 × 10-6
$ 120.00 -
FANGZHOU E-331 2-in-1 electrode conventional sample
$ 96.00 -
Bante930-CN Laboratory Water Quality pH Meter
$ 490.00
Introduction
TP110 pH analyzer is a new generation of high-end instrument with Chinese and English menu-based operation, full intelligence, multi-function, high measurement performance, strong environmental adaptability, etc., which can accurately measure the pH value and temperature of the solution.

Features
High-precision triple compound electrode, accurate and convenient measurement
Professional chip placement process and integrated design, highly integrated circuit design is stable and durable
Professional microcontroller technology, high performance, low power consumption
24-bit A/D signal acquisition, high-precision measurement, accurate and reliable
Chinese menu operation, easy to understand, quick and convenient operation
The standard output signal type is optional, and the alarm relay can be set arbitrarily
Data cycle storage function, automatic removal of overflow data, simple operation, convenient query, power failure data storage time of more than 10 years
TIMEPOWER TP110 (sewage) PH AnalyzerSpecifications
| LIST | VALUE |
|---|---|
| PH range | 0.00~14.00pH |
| PH Measurement Accuracy | ±0.02pH |
| Resolution | 0.01 |
| Measurement range | 0~60℃ |
| Dimensions | 145*120*150mm |
| Weight | 0.64kg |
| Display | 128 * 64 dot matrix LCD, Chinese display |
| Repeatability | < 1% |
| Temperature sensor | Pt1000 |
| water sample pressure | < 0.6 MPa |
| Water sample temperature | 5~60℃ |
| Environmental temperature | 5~45℃ |
| Allowable Relative Humidity | ≤ 90% RH (non-condensing) |
| Storage environment | -25~55℃ |
| Current Output | 0~10mA, 0~20mA, 4~ 20mA optional, load < 300Ω |
| Alarm relay | 2 normally open points can be set arbitrarily, AC220V 3A /DC30V 3A |
| Protection level | IP65 |
| Power down save | > 10 years |
| Power Supply | AC (85~ 265) V Frequency (45~ 65) HZ |
| Power | ≤ 15W |
| opening size | 138*138mm |
TIMEPOWER TP110 (sewage) PH Analyzer Packing list
Host X1, sewage electrode X1, 5 meters cable X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJF 919-2023
- ActiveHJ/T 96-2003
- ActiveGB/T 6920-1986
- ActiveGB/T 9724-2007
- ActiveGB/T 22592-2008
- ActiveGB/T 2390-2013
- ActiveGB/T 14518-1993
- ActiveISO 19396-2-2017
- ActiveISO 19396-1-2017
- ActiveGB/T 21894-2008
- ActiveGB/T 7044-2022
- ActiveGB/T 6368-2008
- ActiveGB 8325-1987
- ActiveGB/T 13531.1-2008
- ActiveGB/T 11165-2005
- ActiveQB/T 2724-2005
- ActiveJB/T 6858-1993
- ActiveHG/T 4164-2010
- ActiveQB/T 4103-2010
- ActiveGB/T 2750-2011


TP110 (sewage)





